5. ELECTRICAL CONNECTIONS

REMEMBER - Turn off the power! NOTE - Control must be installed within 30 feet of fan.
NOTE: This remote control unit is equipped
with 16 code combinations to prevent
possible interference from or to other remote
units. The frequency switches on your
receiver and transmitter have been preset
at the factory. Please recheck to make sure
the switches on the transmitter and the
receiver are set to the same position, any
combination of settings will operate the
fan as long as the transmitter and receiver
are set to the same position. (Fig. 8)
Use the wire nuts supplied with your fan
when making connections. Secure the
connectors with electrical tape and make
sure there are no loose connections or wire
strands.
1. Make wire connections from the fan to
the receiver. (Fig. 9)
Connect the 2-pin connector from
fan to the 2-pin connector from
receiver.
Connect the 3-pin connector from
fan to the 3-pin connector from
receiver.
2. Connect the wiring from the ceiling to
the receiver unit. (Use the 2 wire bundle on
the receiver.) Secure with supplied wire nuts.
Connect the BLACK building supply
wire to the BLACK receiver wire.
Connect the WHITE receiver neutral
wire to the WHITE building neutral
wire.
Connect the COPPER building ground
wire to the YELLOW / GREEN fan
ground wire. Also connect the two
GREEN wires (from fan) to building
ground wire.
3. Connect the wiring from the wall switch
receptacle to wall transmitter unit.
Remove the existing wall plate and
switch from the wall junction box.
Connect one BLACK wire from the
wall to one BLACK wire (labeled
"TO FAN") from the wall transmitter.
Connect the other BLACK wire
(labeled "TO POWER SUPPLY")
from the transmitter to the remaining BLACK
wire from the wall (A/C supply source).
If your junction box has a ground wire
(green or bare copper), connect the
transmitter's ground wire to it. Otherwise,
connect the transmitter ground wire directly
to one of the screws from the outlet box.
Carefully tuck the connected wires inside
the junction box. Secure the transmitter
with the two screws provided. Attach the
face plate over the transmitter with the
two screws provided.
4. Put the receiver unit inside the canopy.
Proceed to Step 6 - Completing the
Installation.
Fig. 9
House
supply
wire
Wall control
Fan canopy
Use ONLY wall controls approved by
Quorum. Use of unapproved wall controls
will cause unacceptable humming noise,
and avoids the fan warranty.
Fig. 8
Code dip switch
BLK
GRN (downrod)
GRN (hanger bracket)
Outlet box
Ceiling
Receiver