WPL 33
Compact air/water heat pump
Installation instructions
The installation (water and electrical work) and commissioning, as well as the maintenance of this
equipment, must only be carried out by an authorised qualified contractor in accordance with these
instructions.
Index
1
General
1.1
Equipment description
1.2
Function
1.3
Correct operation
1.4
Incorrect operation
1.5
Regulations and standards
1.6
Standard delivery and accessories
2
Specification
2.1
Specification
2.2
Performance diagram
2.3
Performance diagram
3
Installation, connection, sound emissions and
commissioning
3.1
Transport
3.2
Installation location
3.3
Noise emissions
3.4
Installing the base unit
3.5
Base unit assembly
3.6
Heating water connection
3.7
Circulation pump
3.8
Condensate drain
3.9
Buffer cylinder
3.10 Second heat source
3.11 Checking the fan
3.12 Installing casing components
3.13 Routing air hoses
3.14 Fitting air hoses
3.15 Insulating wall outlet
4
Electrical connection
5
Commissioning
6
Operation and control
7
Maintenance and cleaning
7.1
Maintenance
7.2
Cleaning
8
Fault remedies
Commissioning report
Information for the owner of the
heat pump heating system
Keep these operating instructions safely and
pass them on to any new user, should the
equipment change hands. Let your contractor
check their content in conjunction with
required maintenance or repair work.
Risk of injury
Where children or persons with
limited physical, sensory or mental
capabilities are to be allowed to control this
appliance, ensure that this will only happen
under supervision or after appropriate
instructions by a person responsible for
their safety.
Children should be supervised to ensure
that they do not play with the appliance.
2
2
2
2
2
2
2
3
3
4
5
6
6
6
6
7
7
7
9
9
9
9
10
10
11
12
12
13
17
17
17
17
17
18
19

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the WPL 33 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for STIEBEL ELTRON WPL 33

  • Page 1 WPL 33 Compact air/water heat pump Installation instructions Index General Equipment description Function Correct operation Incorrect operation Regulations and standards Standard delivery and accessories Specification Specification Performance diagram Performance diagram Installation, connection, sound emissions and commissioning Transport Installation location Noise emissions...
  • Page 2: Installation Instructions

    - Comprises all components required for its function and all safety equipment. 1.6 Standard delivery and accessories - Central control of the heating system and Type WPL 33 safety functions through the WPM heat pump manager (required accessory, part Standard delivery – external installation Part no.
  • Page 3 2 Specification (check details on the rating plate) 2.1 Specification (equipment information) qT< | ®| ® Order no. 185348 Height 1116 Width 1332 Depth Weight Height (internal installation) 1182 Width (internal installation) 1390 Depth (internal installation) Height (external installation) 1434 Width (external installation) 1390 Depth (external installation)
  • Page 4 2.2 Output diagram for heat pump WPL 33 (both compressors) Flow temperature 35°C Flow temperature 50°C Flow temperature 60°C Inlet temperature of the WQA (= heat source system) medium [°C] Fig. 1a...
  • Page 5 2.3 Output diagram for heat pump WPL 33 (single compressor) Flow temperature 35°C Flow temperature 50°C Flow temperature 60°C Inlet temperature of the WQA (= heat source system) medium [°C] Fig. 1b...
  • Page 6 3 Installation, connection and External installation 1280 sound emissions 3.1 Transport Protect the heat pump against severe impact. Short tipping to one of its longitudinal sides is permissible. The casing, cover (in case of external installations) and the cover with air hose connections (for internal installation) are separate shipping units, which will only be assembled to the base unit on site.
  • Page 7 Foundation for external installation Recess screed and impact sound insulation. Main wind direction /XIWDXVWULWWVHLWH +DXSWZLQGULFKWXQJ when using pressure hoses Air outlet side  1 Impact sound installation Dimensions in mm Air inlet side 2 Floating screed /XIWHLQWULWWVHLWH Fig. 4 Fig. 6 Main wind direction Air outlet side Curb stones for external...
  • Page 8 3.6.4 Flushing the heating system Water and electrical connections in external installations Thoroughly flush the pipework before connecting the heat pump. Debris, such as welding pearls, rust, sand, sealant etc. can impair the operational reliability of the heat pump, and can lead to a blocking of the evaporator.
  • Page 9 3.10 Second heat source is insufficient. Decisive for scaling is the concentration of calcium hydrogen carbonate, For dual-mode systems, always connect the which can be supplied by your water supply heat pump into the return of the second heat company. source (e.g.
  • Page 10: Installing The Casing

    3.12 Installing casing components 3.12.1 Installing the casing (external installation example ª Hang the side sheets with the pre-cut holes onto the hooks on the appliance. 1 Side panel 2 Hood (different for internal / external installation) 3 Front door 4 Type plate 5 Back door ª...
  • Page 11 ª Seal gap around the cut-out with fabric tape. ª Now seal the front in the same way. Installing casing components 1 Hose connection plate 2 Hose clip (oval) 3 Air hose 4 Hose clip (oval) 5 Hood Hose connection plate dimensions 1 Side panel  2 Hood (different for internal / external installation)
  • Page 12 3.14 Fitting air hoses The example below shows the air hose connection being fitted. ª Pull the outer hose over the connector. ª Firstly, push the outer hose slightly upwards. ª Secure the hose using the oval hose clip provided. ª...
  • Page 13: Electrical Connection

    4.3 Terminals inside the HP 4.6 Stand alone operation 4 Electrical connection Terminals are inside the WPL control panel In emergencies, this heat pump can also (Fig. 13). The terminals become accessible by operate without the heat pump manager (see 4.1 Power supply company removing the front panel.
  • Page 14 Mains impedance: Zmax ≤ 0.296 : 3/PE~400/50 3/N/PE~400/50 1/N/PE~230/50 Mains supply WP Heat pump (compressor) L1, L2, L3, PE DHC Supplementary heater N, L1, L2, L3, PE Terminal - control 3ORPEHQGUDKW GXUFK GLH Mains supply: L, N, PE 6FKUDXEHQN|SIH  Connected Terminal load...
  • Page 15 Wiring diagram for heat pumps WPL 33 Fig. 14...
  • Page 16 Electrical connection diagram for heat pumps WPL 33 with heat pump manager WPM II Heat Pump Manager WPM II max. 2 A gl 1/N/PE ~ 50Hz 230V 16 A gl Supply from the domestic meter Time switch for power OFF periods...
  • Page 17: Maintenance And Cleaning

    5 Commissioning 7 Maintenance and cleaning 7.1 Maintenance See the operating instructions for the heat pump manager WPM II. The heat pump operates under automatic control and requires no specific maintenance. Set parameter HEAT PUMP DHW STAGES either to 01 or to 02 if DHW Keep the air inlet and outlet openings of the heating/loading is required.
  • Page 18: Troubleshooting

    2, subject to the heat Switch ON: STAND ALONE operation can recommence 10 minutes after the fault has pump type WPL 33. Should the WPM develop a fault, the heat been removed; the LED goes out.
  • Page 19: Commissioning Report

    Commissioning report...