- If the heat pump is completely switched OFF and CAUTION Failure to observe this information may result in non-seri- ous or minor injury. there is a risk of frost, drain the system on the water side. www.stiebel-eltron.com WPL 10 AC | WPL 10 ACS |...
For safety reasons, only operate the appliance with cordance with the conditions defined in the norm shown in the the casing closed. heading of this section. | WPL 10 AC | WPL 10 ACS www.stiebel-eltron.com...
The system is operated exclusively with the heat pump manager (WPM). f Please observe the instructions for the heat pump manager. www.stiebel-eltron.com WPL 10 AC | WPL 10 ACS |...
This can cause the pliance. humidity in the outdoor air to accumulate as dew or frost on the cooled heat pump casing.. This is not a defect. | WPL 10 AC | WPL 10 ACS www.stiebel-eltron.com...
- Hydraulic module HM(S) (Trend) - Pressure hoses DN 25 - Remote control for heating systems FET - Remote control for heating systems FE7 - Starting current limiter 25 A - Safety temperature controller STB-FB www.stiebel-eltron.com WPL 10 AC | WPL 10 ACS |...
If the air intake and discharge of the appliance are ob- structed by surrounding objects, this may cause a thermal short circuit. | WPL 10 AC | WPL 10 ACS www.stiebel-eltron.com...
WPM heat pump manager A WPM heat pump manager is required to operate the appliance. This controls the entire heating system. f Observe the WPM installation instructions during installation. www.stiebel-eltron.com WPL 10 AC | WPL 10 ACS |...
Where required, you can install our starting current limiter with - If the appliance needs to be tilted during transport, this must 25 A for the WPL 10 AC (see "Additional accessories"). only be for a short time and it must only be tilted on one of its longitudinal sides.
Take the position of the heating flow and return from the fol- lowing diagram: f Remove the transport locks (threaded rods) from the compressor. www.stiebel-eltron.com WPL 10 AC | WPL 10 ACS |...
With a conductivity > 1000 μS/cm, desalination treatment remote control in systems without buffer cylinder is recommended in order to avoid corrosion. Maximum temperature differential on the heating side with indi- vidual room controller and external programming unit: | WPL 10 AC | WPL 10 ACS www.stiebel-eltron.com...
Page 13
DHW mode. Outside temperature [°C] Maximum temperature differential [K] f Make the settings at the circulation pump when the temper- ature differential between the flow and return temperature has stabilised. www.stiebel-eltron.com WPL 10 AC | WPL 10 ACS |...
1 Cable entries f Thread the connecting cables from below through the cable entries upwards to the connecting chamber. | WPL 10 AC | WPL 10 ACS www.stiebel-eltron.com...
Pasteurisation The electric emergency/booster heater starts automat- mode ically when pasteurisation mode is active. The DHW is then regularly heated to 60 °C to protect it against the growth of legionella bacteria. www.stiebel-eltron.com WPL 10 AC | WPL 10 ACS |...
Earth the LV lead by inverting the screen over the external sheath and clamping it under the earth terminal. f Then check that the strain relief fittings are working as intended. | WPL 10 AC | WPL 10 ACS www.stiebel-eltron.com...
Page 17
When making the L and N connections of the compressor and the L and N connections of the control unit in single phase appliances, ensure that the same phase is used. Protect the circuit with an RCD. www.stiebel-eltron.com WPL 10 AC | WPL 10 ACS |...
- Have you correctly connected the power supply? the heat pump manager in accordance with the technical guides. 12.1.4 Transport locks - Have you removed the threaded rods that secure the compressor? | WPL 10 AC | WPL 10 ACS www.stiebel-eltron.com...
Page 19
Factory setting Compressor mode with electric emergency/booster heater 1 IWS WP - Typ f Lift the panel highlighted in grey. f Check whether the DIP switch is set correctly. www.stiebel-eltron.com WPL 10 AC | WPL 10 ACS |...
Observe the WPM operating and installation instructions. The following steps will help you to adjust the heating curve cor- rectly: | WPL 10 AC | WPL 10 ACS www.stiebel-eltron.com...
Initially set the "DUAL MODE TEMP HZG" parameter to 30 °C. Material losses f Set the "LOWER APP LIMIT HZG" parameter to 30 °C. Keep the air discharge and intake apertures free from snow and ice. www.stiebel-eltron.com WPL 10 AC | WPL 10 ACS |...
- High pressure fault f If the noises occur frequently, notify customer support. - Low pressure fault - Other fault and - Hardware fault on the IWS (see fault list) | WPL 10 AC | WPL 10 ACS www.stiebel-eltron.com...
WPL 10 ACS Entry electrical cables Condensate drain Diameter Heating flow Male thread G 1 1/4 G 1 1/4 Heating return Male thread G 1 1/4 G 1 1/4 Air intake Air discharge www.stiebel-eltron.com WPL 10 AC | WPL 10 ACS |...
X40 3-4 pin adaptor – fan Electric emergency/booster heater relay (DHC) Diverter valve Electric emergency/booster heater relay (DHC) Compressor motor Fan motor Stepper motor el. Expansion valve High pressure sensor Low pressure sensor Terminal | WPL 10 AC | WPL 10 ACS www.stiebel-eltron.com...
Page 25
INSTALLATION Specification “+” A2 (IWS II EEV) BU YE RD M _ _ GNYE www.stiebel-eltron.com WPL 10 AC | WPL 10 ACS |...
Electric emergency/booster heater relay (DHC) Diverter valve Electric emergency/booster heater relay (DHC) Run capacitor, compressor Compressor motor Fan motor WPAB Softstart Stepper motor el. Expansion valve High pressure sensor Low pressure sensor | WPL 10 AC | WPL 10 ACS www.stiebel-eltron.com...
Page 27
INSTALLATION Specification “+” A2 (IWS II EEV) BU YE RD M _ _ GNYE www.stiebel-eltron.com WPL 10 AC | WPL 10 ACS |...
Heating output [kW] | Power consumption [kW] | Coefficient of performance ε [-] Flow temperature 35 °C Flow temperature 45 °C Flow temperature 55 °C Flow temperature 60 °C Heating output Power consumption Coefficient of performance (COP) | WPL 10 AC | WPL 10 ACS www.stiebel-eltron.com...
Cooling capacity [kW] | Power consumption cooling [kW] | Coefficient of performance cooling ε [-] Flow temperature +7 °C Flow temperature +18 °C Cooling capacity Power consumption Coefficient of performance (COP) www.stiebel-eltron.com WPL 10 AC | WPL 10 ACS |...
Heating output [kW] | Power consumption [kW] | Coefficient of performance ε [-] Flow temperature 35 °C Flow temperature 45 °C Flow temperature 55 °C Flow temperature 60 °C Heating output Power consumption Coefficient of performance (COP) | WPL 10 AC | WPL 10 ACS www.stiebel-eltron.com...
Cooling capacity [kW] | Power consumption cooling [kW] | Coefficient of performance cooling ε [-] Flow temperature +7 °C Flow temperature +18 °C Cooling capacity Power consumption Coefficient of performance (COP) www.stiebel-eltron.com WPL 10 AC | WPL 10 ACS |...
1 x B 16 B 16 Frequency Rated voltage, compressor Rated voltage, emergency/booster heater Rated voltage, control unit Compressor phases 3/N/PE 1/N/PE Control unit phases 1/N/PE 1/N/PE Emergency/booster heater phases 3/N/PE 1/N/PE | WPL 10 AC | WPL 10 ACS www.stiebel-eltron.com...
Page 33
Min. heating flow rate m³/h Flow rate on heat source side m³/h 2300 2300 Internal pressure differential Further details WPL 10 AC WPL 10 ACS 230236 227995 Maximum altitude for installation 2000 2000 www.stiebel-eltron.com WPL 10 AC | WPL 10 ACS |...
Page 34
This will not affect warranties issued by any importers. Environment and recycling We would ask you to help protect the environment. After use, dispose of the various materials in accordance with national regulations. | WPL 10 AC | WPL 10 ACS www.stiebel-eltron.com...