OPERATION AND INSTALLATION
Air | water heat pump
» WPL 07 ACS classic
» WPL 09 ACS classic
» WPL 17 ACS classic

Advertisement

Table of Contents

Troubleshooting

loading
Need help?

Need help?

Do you have a question about the WPL 07 ACS classic and is the answer not in the manual?

Questions and answers

Summary of Contents for STIEBEL ELTRON WPL 07 ACS classic

  • Page 1 OPERATION AND INSTALLATION Air | water heat pump » WPL 07 ACS classic » WPL 09 ACS classic » WPL 17 ACS classic...
  • Page 2: Table Of Contents

    Connection diagram �������������������������������������������� 24 Minimum software versions ����������������������������������� 5 16.4 Application limit ������������������������������������������������ 26 Operational characteristics ������������������������������������ 5 16.5 Output diagrams WPL 07 ACS classic ����������������������� 27 Function ����������������������������������������������������������� 5 16.6 Output diagrams WPL 09 ACS classic ����������������������� 28 Settings �������������������������������������������������������6 16.7 Output diagrams WPL 17 ACS classic �����������������������...
  • Page 3: Special Information

    SPECIAL INFORMATION | OPERATION General information SPECIAL INFORMATION OPERATION - The appliance may be used by children aged 8 General information and older and persons with reduced physical, sensory or mental capabilities or a lack of ex- The chapters "Special Information" and "Operation" are intended for both the user and qualified contractors.
  • Page 4: Other Symbols In This Documentation

    OPERATION Safety Other symbols in this documentation Safety Note Intended use General information is identified by the adjacent symbol. The appliance is designed for room heating and cooling within f Read these texts carefully. the application limits given in the specification. This appliance is intended for domestic use.
  • Page 5: Appliance Description

    OPERATION Appliance description Appliance description Material losses In the defrost cycle, the fan is switched off and the heat Minimum software versions pump circuit is reversed. The heat required for defrosting is drawn from the buffer cylinder. For operation without a The following minimum software versions are required for oper- buffer cylinder, observe chapter "Operation / Menu struc- ating the heat pump:...
  • Page 6: Settings

    OPERATION Settings Settings If you cannot remedy the fault, notify your qualified contractor. To facilitate and speed up your request, provide the number from the The system is operated exclusively with the WPM heat pump man- type plate. The type plate is located at the front top, on the right ager.
  • Page 7: Safety

    INSTALLATION Safety INSTALLATION 8.2.2 Further accessories - Remote control for heating systems FEK - Remote control for heating systems FE7 - High limit safety cut-out for underfloor heating systems Safety STB-FB Only a qualified contractor should carry out installation, commis- Preparations sioning, maintenance and repair of the appliance.
  • Page 8: Minimum Clearances

    Maintain the minimum clearances to ensure trouble-free op- Heat pump eration of the appliance and facilitate maintenance work. WPL 07 ACS classic WPL 09 ACS classic WPL 17 ACS classic f Lay a drainage pipe under the appliance to drain moisture away from the building.
  • Page 9 Example: T-support SK 2 1 Air intake side 2 Air discharge side 3 Main wind direction Heat pump 1 Drainage pipe WPL 07 ACS classic WPL 09 ACS classic Heat pump WPL 17 ACS classic WPL 07 ACS classic WPL 09 ACS classic...
  • Page 10: Installing The Supply Lines

    INSTALLATION Preparations Installing the supply lines Material losses The T-support may bend if the heat pump is subject to The supply lines are all electric cables plus the heating flow and any lateral load. return lines. f Do not exert any pressure on the sides of the heat f Use only weatherproof cables, e.g.
  • Page 11: Preparing The Electrical Installation

    Provide separate fuses for the two power circuits (for the appliance and the control unit). f Lay the relevant pipe cross-sections. Observe the applicable national and regional regulations. WPL 07 ACS classic | WPL 09 ACS classic MCB/fuse Assignment Cable cross-section...
  • Page 12: Flow And Return Connection

    INSTALLATION Installation 10.3 Flow and return connection Material losses For cooling with fan convectors, the heating flow and heating return lines must be provided with vapour dif- fusion-proof insulation. f Take the position of the heating flow and return from the fol- 1 Retainer lowing diagram: 2 Screw cap...
  • Page 13: Oxygen Diffusion

    INSTALLATION Installation f Ensure that the heating flow and return are connected 10.7.3 Venting the heating system correctly. The appliance has an automatic air vent valve. f Provide thermal insulation in accordance with applicable regulations. f When sizing the heating circuit, observe the internal pressure differential (see chapter “Specification / Data table”).
  • Page 14: External Second Heat Source

    Lead room Number of cir- floor area cuits floor area cuits m² n x m m² n x m WPL 07 ACS classic 400 3x70 2x70 WPL 09 ACS classic 400 3x70 2x70 WPL 17 ACS classic 600 3x70 2x70 Buffer cylinder always Recommended buffer cylinder...
  • Page 15: Electrical Connection

    INSTALLATION Electrical connection 11. Electrical connection Note Observe the operating and installation instructions of the WPM heat pump manager. Connection work must only be carried out by a qualified contractor and in accordance with these instructions. Permission to connect the appliance may need to be obtained from the local power supply utility.
  • Page 16: Commissioning

    INSTALLATION Commissioning 12. Commissioning Material losses Strain relief fittings that are too tight may lead to a short A WPM heat pump manager is required to operate the appliance. circuit. All necessary adjustments prior to and during operation are made f Never tighten them completely.
  • Page 17: Power Interruption

    INSTALLATION Shutdown The following steps will help you to adjust the heating curve cor- 12.3.2 Other settings rectly: f For operation with and without buffer cylinder, observe - Fully open thermostatic or zone valves in a lead room (e.g. chapter "Operation / Menu structure / Menu SETTINGS / living room and bathroom).
  • Page 18: Troubleshooting

    INSTALLATION Troubleshooting 15. Troubleshooting WARNING Electrocution Before working on the appliance, isolate it from the power supply at the control panel. Following disconnection from the power supply, parts of the appliance may remain energised for 2 minutes until the inverter capacitors have discharged. Note Observe the heat pump manager operating and instal- lation instructions.
  • Page 19 INSTALLATION Troubleshooting 15.2 LEDs (IWS) 15.1.1 DIP switch (WP-Typ) With the DIP switch (WP-Typ), you can set the IWS to suit the relevant heat pump type. Factory setting Compressor mode with electric emergency/booster heater Note An emergency/booster heater is installed in some of the products required as accessories (see chapter “Installa- tion / Appliance description / Accessories”).
  • Page 20: Fan Noise

    INSTALLATION Troubleshooting 15.4 Fan noise The heat pump extracts heat from the outdoor air. This causes the outdoor air to cool down. At outside temperatures of 0 °C to 8 °C, the air may be cooled to below freezing point. If, under these conditions, precipitation occurs in the form of rain or fog, ice may form on the air grille, the fan blades or the air routing pipes.
  • Page 21: Dimensions And Connections

    INSTALLATION Specification 16. Specification 16.1 Dimensions and connections WPL 07 ACS classic WPL 09 ACS classic WPL 17 ACS classic appliance Height appliance Width 1022 1022 1152 Entry electrical cables Condensate drain Heating flow Diameter Heating return Diameter Air intake Air discharge www.stiebel-eltron.com...
  • Page 22: Wiring Diagram

    INSTALLATION Specification 16.2 Wiring diagram L1 N 5 turns 5 turns X11.1 PE Versorgung N Versorgung L Versorgung X11.2 Verdichter Schütz N Verdichter Schütz L X11.3 Abtauventil N Abtauventil L X11.4 Ölsumpfheizung N Ölsumpfheizung L X11.5 1 turn 5 turns N PE Düsenheizung X11.6...
  • Page 23 INSTALLATION Specification 5 turns X12.1 X12.2 Heißgastemperatur Heißgastemperatur GND Heizungsrücklauftemperatur Heizungsrücklauftemperatur GND Außenlufttemperatur Außenlufttemperatur GND Verdichtereintrittstemperatur Verdichtereintrittstemperatur GND Verdampferausgangstemperatur Verdampferausgangstemperatur GND Ölsumpf Ölsumpf GND X12.3 CAN GND CAN L CAN H (IWS IV) X12.4 +12..+18V ND 4..20mA +12...+18V HD 4...20mA X12.5 +12V Phase 4...
  • Page 24: Connection Diagram

    INSTALLATION Specification 16.3 Connection diagram WPL 07 ACS classic | WPL 09 ACS classic | WPL 17 ACS classic with HM(S) (Trend) nc H L 1 Heat pump 2 Fuse box 3 HM(S) (Trend) A Power-OFF contact | WPL ACS classic...
  • Page 25 INSTALLATION Specification WPL 07 ACS classic | WPL 09 ACS classic | WPL 17 ACS classic with HSBB 200 (S) classic | HSBC 200 (S) X2.1 X2.2 nc H L 1 Heat pump 2 Fuse box 3 HSBB 200 (S) classic...
  • Page 26: Application Limit

    INSTALLATION Specification 16.4 Application limit 16.4.1 Heating X Outside temperature [°C] Y Flow temperature [°C] 16.4.2 Cooling X Outside temperature [°C] Y Flow temperature [°C] | WPL ACS classic www.stiebel-eltron.com...
  • Page 27: Output Diagrams Wpl 07 Acs Classic

    INSTALLATION Specification 16.5 Output diagrams WPL 07 ACS classic Heating output X Outside temperature [°C] Y Heating output [kW] 1 Max. W55 2 Max. W45 3 Max. W35 4 Min. W55 5 Min. W45 6 Min. W35 Cooling capacity X Flow temperature [°C] Y Cooling capacity [kW] 1 Max.
  • Page 28: Output Diagrams Wpl 09 Acs Classic

    INSTALLATION Specification 16.6 Output diagrams WPL 09 ACS classic Heating output X Outside temperature [°C] Y Heating output [kW] 1 Max. W55 2 Max. W45 3 Max. W35 4 Min. W55 5 Min. W45 6 Min. W35 Cooling capacity X Flow temperature [°C] Y Cooling capacity [kW] 1 Max.
  • Page 29: Output Diagrams Wpl 17 Acs Classic

    INSTALLATION Specification 16.7 Output diagrams WPL 17 ACS classic Heating output X Outside temperature [°C] Y Heating output [kW] 1 Max. W55 2 Max. W45 3 Max. W35 4 Min. W55 5 Min. W45 6 Min. W35 Cooling capacity X Flow temperature [°C] Y Cooling capacity [kW] 1 Max.
  • Page 30 The power consumption figures for the integral auxiliary drives are maximum values and may vary subject to operating point. The power consumption of the integral auxiliary drives is included in the output details of the heat pump (to EN 14511). WPL 07 ACS classic WPL 09 ACS classic...
  • Page 31 INSTALLATION | GUARANTEE | ENVIRONMENT AND RECYCLING Specification WPL 07 ACS classic WPL 09 ACS classic WPL 17 ACS classic Dimensions Height Width 1022 1022 1152 Depth Weights Weight Connections Connection, heating flow/return 22 mm 22 mm 22 mm Water quality requirements Water hardness °dH...
  • Page 32   Deutschland Verkauf Tel. 05531 702-110 | Fax 05531 702-95108 | info-center@stiebel-eltron.de STIEBEL ELTRON GmbH & Co. KG Kundendienst Tel. 05531 702-111 | Fax 05531 702-95890 | kundendienst@stiebel-eltron.de Dr.-Stiebel-Straße 33 | 37603 Holzminden Ersatzteilverkauf Tel. 05531 702-120 | Fax 05531 702-95335 | ersatzteile@stiebel-eltron.de Tel.