SPECIAL INFORMATION | OPERATION General information SPECIAL INFORMATION OPERATION - The appliance may be used by children aged 8 General information and older and persons with reduced physical, sensory or mental capabilities or a lack of ex- The chapters "Special Information" and "Operation" are intended for both the user and qualified contractors.
OPERATION Safety Other symbols in this documentation Safety Note Intended use General information is identified by the adjacent symbol. The appliance is designed for room heating and cooling within f Read these texts carefully. the application limits given in the specification. This appliance is intended for domestic use.
OPERATION Appliance description Appliance description Material losses In the defrost cycle, the fan is switched off and the heat Minimum software versions pump circuit is reversed. The heat required for defrosting is drawn from the buffer cylinder. For operation without a The following minimum software versions are required for oper- buffer cylinder, observe chapter "Operation / Menu struc- ating the heat pump:...
OPERATION Settings Settings If you cannot remedy the fault, notify your qualified contractor. To facilitate and speed up your request, provide the number from the The system is operated exclusively with the WPM heat pump man- type plate. The type plate is located at the front top, on the right ager.
INSTALLATION Safety INSTALLATION 8.2.2 Further accessories - Remote control for heating systems FEK - Remote control for heating systems FE7 - High limit safety cut-out for underfloor heating systems Safety STB-FB Only a qualified contractor should carry out installation, commis- Preparations sioning, maintenance and repair of the appliance.
Maintain the minimum clearances to ensure trouble-free op- Heat pump eration of the appliance and facilitate maintenance work. WPL 07 ACS classic WPL 09 ACS classic WPL 17 ACS classic f Lay a drainage pipe under the appliance to drain moisture away from the building.
Page 9
Example: T-support SK 2 1 Air intake side 2 Air discharge side 3 Main wind direction Heat pump 1 Drainage pipe WPL 07 ACS classic WPL 09 ACS classic Heat pump WPL 17 ACS classic WPL 07 ACS classic WPL 09 ACS classic...
INSTALLATION Preparations Installing the supply lines Material losses The T-support may bend if the heat pump is subject to The supply lines are all electric cables plus the heating flow and any lateral load. return lines. f Do not exert any pressure on the sides of the heat f Use only weatherproof cables, e.g.
Provide separate fuses for the two power circuits (for the appliance and the control unit). f Lay the relevant pipe cross-sections. Observe the applicable national and regional regulations. WPL 07 ACS classic | WPL 09 ACS classic MCB/fuse Assignment Cable cross-section...
INSTALLATION Installation 10.3 Flow and return connection Material losses For cooling with fan convectors, the heating flow and heating return lines must be provided with vapour dif- fusion-proof insulation. f Take the position of the heating flow and return from the fol- 1 Retainer lowing diagram: 2 Screw cap...
INSTALLATION Installation f Ensure that the heating flow and return are connected 10.7.3 Venting the heating system correctly. The appliance has an automatic air vent valve. f Provide thermal insulation in accordance with applicable regulations. f When sizing the heating circuit, observe the internal pressure differential (see chapter “Specification / Data table”).
Lead room Number of cir- floor area cuits floor area cuits m² n x m m² n x m WPL 07 ACS classic 400 3x70 2x70 WPL 09 ACS classic 400 3x70 2x70 WPL 17 ACS classic 600 3x70 2x70 Buffer cylinder always Recommended buffer cylinder...
INSTALLATION Electrical connection 11. Electrical connection Note Observe the operating and installation instructions of the WPM heat pump manager. Connection work must only be carried out by a qualified contractor and in accordance with these instructions. Permission to connect the appliance may need to be obtained from the local power supply utility.
INSTALLATION Commissioning 12. Commissioning Material losses Strain relief fittings that are too tight may lead to a short A WPM heat pump manager is required to operate the appliance. circuit. All necessary adjustments prior to and during operation are made f Never tighten them completely.
INSTALLATION Shutdown The following steps will help you to adjust the heating curve cor- 12.3.2 Other settings rectly: f For operation with and without buffer cylinder, observe - Fully open thermostatic or zone valves in a lead room (e.g. chapter "Operation / Menu structure / Menu SETTINGS / living room and bathroom).
INSTALLATION Troubleshooting 15. Troubleshooting WARNING Electrocution Before working on the appliance, isolate it from the power supply at the control panel. Following disconnection from the power supply, parts of the appliance may remain energised for 2 minutes until the inverter capacitors have discharged. Note Observe the heat pump manager operating and instal- lation instructions.
Page 19
INSTALLATION Troubleshooting 15.2 LEDs (IWS) 15.1.1 DIP switch (WP-Typ) With the DIP switch (WP-Typ), you can set the IWS to suit the relevant heat pump type. Factory setting Compressor mode with electric emergency/booster heater Note An emergency/booster heater is installed in some of the products required as accessories (see chapter “Installa- tion / Appliance description / Accessories”).
INSTALLATION Troubleshooting 15.4 Fan noise The heat pump extracts heat from the outdoor air. This causes the outdoor air to cool down. At outside temperatures of 0 °C to 8 °C, the air may be cooled to below freezing point. If, under these conditions, precipitation occurs in the form of rain or fog, ice may form on the air grille, the fan blades or the air routing pipes.
INSTALLATION Specification 16.2 Wiring diagram L1 N 5 turns 5 turns X11.1 PE Versorgung N Versorgung L Versorgung X11.2 Verdichter Schütz N Verdichter Schütz L X11.3 Abtauventil N Abtauventil L X11.4 Ölsumpfheizung N Ölsumpfheizung L X11.5 1 turn 5 turns N PE Düsenheizung X11.6...
Page 23
INSTALLATION Specification 5 turns X12.1 X12.2 Heißgastemperatur Heißgastemperatur GND Heizungsrücklauftemperatur Heizungsrücklauftemperatur GND Außenlufttemperatur Außenlufttemperatur GND Verdichtereintrittstemperatur Verdichtereintrittstemperatur GND Verdampferausgangstemperatur Verdampferausgangstemperatur GND Ölsumpf Ölsumpf GND X12.3 CAN GND CAN L CAN H (IWS IV) X12.4 +12..+18V ND 4..20mA +12...+18V HD 4...20mA X12.5 +12V Phase 4...
INSTALLATION Specification 16.4 Application limit 16.4.1 Heating X Outside temperature [°C] Y Flow temperature [°C] 16.4.2 Cooling X Outside temperature [°C] Y Flow temperature [°C] | WPL ACS classic www.stiebel-eltron.com...
INSTALLATION Specification 16.7 Output diagrams WPL 17 ACS classic Heating output X Outside temperature [°C] Y Heating output [kW] 1 Max. W55 2 Max. W45 3 Max. W35 4 Min. W55 5 Min. W45 6 Min. W35 Cooling capacity X Flow temperature [°C] Y Cooling capacity [kW] 1 Max.
Page 30
The power consumption figures for the integral auxiliary drives are maximum values and may vary subject to operating point. The power consumption of the integral auxiliary drives is included in the output details of the heat pump (to EN 14511). WPL 07 ACS classic WPL 09 ACS classic...
Page 31
INSTALLATION | GUARANTEE | ENVIRONMENT AND RECYCLING Specification WPL 07 ACS classic WPL 09 ACS classic WPL 17 ACS classic Dimensions Height Width 1022 1022 1152 Depth Weights Weight Connections Connection, heating flow/return 22 mm 22 mm 22 mm Water quality requirements Water hardness °dH...