NORDICCO NORTHERN LIGHT
E
E
n
n
g
g
l
l
i
i
s
s
h
h
ENGLISH
Please note: this manual is not applicable for installations performed in Denmark. In this case, please see Danish manual.
w
1
Vers. 3.0
L
L
A
A
T
T
I
I
O
O
N
N
M
M
C
C
C
C
O
O
N
N
O
O
R
R
T
T
I I M M P P O O R R T T A A N N T T S S A A F F E E T T Y Y W W A A R R N N I I N N G G
T
T
H
H
I
I
S
S
S
S
Y
Y
I
I
N
N
C
C
O
O
R
R
R
R
THIS SYSTEM USES INTEGRATED UVC LIGHT SOURCES. INCORRECT INSTALLA-
W
W
A
A
R
R
N
N
I
I
N
N
TION AND/OR USAGE CAN CAUSE INJURY. WARNING: NEVER LOOK DIRECTLY
INTO UVC LIGHT SOURCES.
P
P
L
L
E
E
A
A
S
S
E
E
R
R
E
E
Q
Q
U
U
I
I
R
R
PLEASE NOTE THAT SPECIFIC LOCAL OR NATIONAL REQUIREMENTS MAY AP-
O
O
F
F
U
U
V
V
C
C
PLY TO THE INSTALLATION AND USAGE OF UVC EQUIPMENT. IT IS THE SOLE
I
I
N
N
S
S
T
T
A
A
L
L
L
L
RESPONSIBILITY OF THE INSTALLER TO ENSURE FULL COMPLIANCE WITH
A
A
N
N
D
D
/
/
O
O
R
R
ANY LOCAL AND/OR NATIONAL REQUIREMENTS, INCLUDING ANY REQUIRED
A
A
U
U
T
T
H
H
O
O
AUTHORIZATIONS.
W
W
E
E
R
R
E
E
C
C
WE RECOMMEND THAT INSTALLED SYSTEMS ARE INSPECTED (BY A
A A P P R R O O F F E E S S S S I I O O N N A A L L U U V V C C T T E E C C H H N N I I C C I I A A N N ) ) E E V V E E R R Y Y S S I I X X M M O O N N T T H H S S . .
PROFESSIONAL UVC TECHNICIAN) EVERY SIX MONTHS.
A
A
N
N
U
U
A
A
L
L
&
&
U
U
H
H
E
E
R
R
N
N
L
L
I
I
G
G
H
H
IMPORTANT SAFETY WARNING
S
S
T
T
E
E
M
M
U
U
S
S
E
E
S
S
I
I
N
N
T
T
E
E
G
G
R
R
A
A
T
T
E
E
C
C
T
T
I
I
N
N
S
S
T
T
A
A
L
L
L
L
A
A
T
T
I
I
O
O
N
N
A
A
G
G
:
:
N
N
E
E
V
V
E
E
R
R
L
L
O
O
O
O
K
K
D
D
I
I
R
R
N
N
O
O
T
T
E
E
T
T
H
H
A
A
T
T
S
S
P
P
E
E
C
C
I
I
F
F
I
I
C
C
E
E
M
M
E
E
N
N
T
T
S
S
M
M
A
A
Y
Y
A
A
P
P
P
P
L
L
Y
Y
E
E
Q
Q
U
U
I
I
P
P
M
M
E
E
N
N
T
T
.
.
I
I
T
T
I
I
S
S
T
T
H
H
E
E
R
R
T
T
O
O
E
E
N
N
S
S
U
U
R
R
E
E
F
F
U
U
L
L
L
L
N
N
A
A
T
T
I
I
O
O
N
N
A
A
L
L
R
R
E
E
Q
Q
U
U
I
I
R
R
E
E
R
R
I
I
Z
Z
A
A
T
T
I
I
O
O
N
N
S
S
.
.
O
O
M
M
M
M
E
E
N
N
D
D
T
T
H
H
A
A
T
T
I
I
N
N
S
S
T
T
S
S
E
E
R
R
G
G
U
U
I
I
D
D
E
E
T
T
H
H
V
V
L
L
S
S
F
F
®
®
HVLS FAN
®
E
E
D
D
U
U
V
V
C
C
L
L
I
I
G
G
H
H
T
T
S
S
O
O
U
U
R
R
N
N
D
D
/
/
O
O
R
R
U
U
S
S
A
A
G
G
E
E
C
C
A
A
N
N
E
E
C
C
T
T
L
L
Y
Y
I
I
N
N
T
T
O
O
U
U
V
V
C
C
L
L
I
I
G
G
H
H
L
L
O
O
C
C
A
A
L
L
O
O
R
R
N
N
A
A
T
T
I
I
O
O
N
N
A
A
T
T
O
O
T
T
H
H
E
E
I
I
N
N
S
S
T
T
A
A
L
L
L
L
A
A
T
T
I
I
O
O
E
E
S
S
O
O
L
L
E
E
R
R
E
E
S
S
P
P
O
O
N
N
S
S
I
I
B
B
I
I
L
L
C
C
O
O
M
M
P
P
L
L
I
I
A
A
N
N
C
C
E
E
W
W
I
I
T
T
H
H
A
A
M
M
E
E
N
N
T
T
S
S
,
,
I
I
N
N
C
C
L
L
U
U
D
D
I
I
N
N
G
G
A
A
L
L
L
L
E
E
D
D
S
S
Y
Y
S
S
T
T
E
E
M
M
S
S
A
A
R
R
E
E
A
A
N
N
C
C
E
E
S
S
.
.
C
C
A
A
U
U
S
S
E
E
I
I
N
N
J
J
U
U
R
R
Y
Y
.
.
T
T
S
S
O
O
U
U
R
R
C
C
E
E
S
S
.
.
L
L
N
N
A
A
N
N
D
D
U
U
S
S
A
A
G
G
E
E
I
I
T
T
Y
Y
O
O
F
F
T
T
H
H
E
E
N
N
Y
Y
L
L
O
O
C
C
A
A
L
L
A
A
N
N
Y
Y
R
R
E
E
Q
Q
U
U
I
I
R
R
E
E
D
D
I
I
N
N
S
S
P
P
E
E
C
C
T
T
E
E
D
D
(
(
B
B
Y
Y

Advertisement

Table of Contents
loading

Summary of Contents for NORDICCO HVLS

  • Page 1 INSTALLATION MANUAL & USER GUIDE & & ® ® NORDICCO NORTHERN LIGHT HVLS FAN ® ENGLISH Please note: this manual is not applicable for installations performed in Denmark. In this case, please see Danish manual. I I M M P P O O R R T T A A N N T T S S A A F F E E T T Y Y W W A A R R N N I I N N G G IMPORTANT SAFETY WARNING THIS SYSTEM USES INTEGRATED UVC LIGHT SOURCES.
  • Page 2: Before You Begin

    CLOSED PLASTIC BAG AND DEPOSIT AT YOUR LOCAL RECYCLING STATION. DO NOT USE A VACUUM CLEANER. IT IS EXTREMELY IMPORTANT THAT YOU READ CAREFULLY AND UNDERSTAND THIS INSTALLATION MANUAL IN ITS ENTIRETY BEFORE USING THE NORDICCO NORTHERN LIGHT HVLS FAN. INCORRECT USE MAY CAUSE SEVERE PHYSICAL ®...
  • Page 3: General Safety Information

    WARNING To reduce the risk of fire, electric shock or personal injury, the following must be observed: 1. Use this system only as instructed by Nordicco A/S. If you have any questions, please contact Nordicco A/S or its representatives. 2. Before servicing or cleaning the system, turn off the power to the control unit and disconnect it from the main supply to prevent the power from being turned on accidentally.
  • Page 4: Table Of Contents

    CONTENTS BEFORE YOU BEGIN ....................... 2 GENERAL SAFETY INFORMATION ..................3 CONTENTS ..........................4 INSTALLATION AND COMMISSIONING ................. 5 PART 1 MOUNTING & CONNECTION OF FAN (EXCLUDING UVC SYSTEM) ..................6 PRE-INSTALLATION CHECK ................................7 FIRE PRECAUTIONS ..................................8 BEST PRACTICE IN RELATION TO FIRE AND FIRE HAZARDS ......................8 INSIDE THE BOX .....................................
  • Page 5: Installation And Commissioning

    Figure 1 are each described below and illustrated in PART 1: Installation of the HVLS fan This part of the installation can be performed by an installer with a technically relevant qualification, such as a Service Engineer or electrical fitter. The installer is responsible for the processes and procedures presented in Part 1 of this installation manual.
  • Page 6: Part 1 Mounting & Connection Of Fan (Excluding Uvc System)

    PART 1 MOUNTING & CONNECTION OF FAN (EXCLUDING UVC SYSTEM)
  • Page 7: Pre-Installation Check

    If in doubt, contact Nordicco A/S for the processing of a damage report and the replacement of spare parts if necessary.
  • Page 8: Fire Precautions

    Flame detectors are typically used in rooms with high ceilings and in atriums. The HVLS fans should not be installed in the line of sight of a linear smoke detector, as this may cause false alarms to trigger on the Automatic Fire Alarm system. A linear smoke detector uses invisible beams of ultraviolet and infra-red light.
  • Page 9 Scenario 3: HVLS fans installed in a room where sprinkler systems are installed. The actions listed in scenario 1 should be followed, in addition to the following points, which are recommended by the NFPA (National Fire Protection Association): The largest HVLS fan diameter should not exceed 8 meters.
  • Page 10: Inside The Box

    INSIDE THE BOX Saddle Drop Tube Drive and Onboard Electronics Motor Controller (if ordered) Starfish Blade Hub Patch cable (optional) 230V power cable (3 x 1.0 mm Fire alarm cable Mount Cover (if ordered) Safety wire Safety wire lock (Gripple) 2 x Extension Tubes 2 x Alu Extension Connectors Required screws and bolts...
  • Page 11 UVC aperture shields / emission dampers Percentage reduction of irradiation using various aperture shields SCREWS FOR MOUNTING Anodised AIR BLADES aluminium air 6 x 16mm (10 pcs) blades with UVC lock spring washers (10 pcs) system Required screws NO DRILL BIT NEEDED...
  • Page 12: Required Tools & Accessories

    If this is not the case, additional mounting brackets can be used. Contact your Nordicco supplier. For installations that use optional mounting brackets or additional stabilizing wires, refer to the manuals for these,...
  • Page 13: Standard Installation Process

    IF YOU ARE UNABLE TO INSTALL DIRECTLY ON THE MOUNTING SURFACE, YOU CAN USE EXTRA MOUNTING BRACKETS. SEE SEPARATE MANUAL OR CONTACT YOUR NORDICCO SUPPLIER: WWW.NORDICCO.EU/DOWNLOADS Attach the safety wire around the IF ORDERED: Push up the mount mounting beam.
  • Page 14: Installing & Securing The Safety Wire

    INSTALLING & SECURING THE SAFETY WIRE Insert the wire by inserting it into and turning it Pull the wire through Pull the wire around the mounting beam and insert the clockwise. wire into . Follow the direction of the arrows. Tighten the wire.
  • Page 15: Air Blade Installation

    AIR BLADE INSTALLATION PLEASE NOTE: Make sure that the fan is vertically and horizontally levelled before mounting the blades. IMPORTANT: Do not use the fan without mounting the blades, as this may damage the motor and drive. IMPORTANT: Systems must NOT Position the blade onto the starfish Secure the blade with specified be connected to a power supply...
  • Page 16: Fire Alarm Installation

    FIRE ALARM INSTALLATION OPTIONAL FIRE ALARM INSTALLATION Note: This section is only relevant in buildings equipped with fire extinguishing systems. For buildings with no fire suppression system, simply leave the fire cable untouched inside the drop tube. Important: The fire alarm relay must only be installed by qualified persons who understand how to deal with fire suppression systems.
  • Page 17: Connection Of Power And Tablet

    Please note : It can take up to 20 minutes until the system is online after connecting to 230V. • Nordicco HMI Controller: Insert the patch cable in the controller and see the manual for HMI- Controller for further steps.
  • Page 18: Cleaning And Maintenance

    We recommend that installed systems are inspected by a UVC-professional every six months. REPAIRS AND SPARE PARTS Contact Nordicco for access to spare parts and guidance on how to perform repairs and replacement of spare parts. When repairs are required, contact Nordicco.
  • Page 19: Part 2 Activation And Commissioning Of The Northern Light Uvc System According To En 14255-1

    PART 2 ACTIVATION AND COMMISSIONING OF THE NORTHERN LIGHT UVC SYSTEM ACCORDING TO EN 14255-1 ACTIVATION OF THE UVC SYSTEM IS PROTECTED WITH AN ACTIVATION CODE. ONLY PROFFESSIONAL UVC INSTALLERS MAY ACTIVATE AND ADJUST THE UVC SYSTEM BEFORE COMMISSIONING. UVC ACTIVATION CODE: 7000#Karet...
  • Page 20: General Instructions

    GENERAL INSTRUCTIONS UVC irradiation measurements are required in several cases, including: o At first installation o When installing new UVC light sources o When moving the fan to a new position in the room o When making changes or adjustments in the room (e.g. height, position, change in placement of walls or ceiling and wall materials, change in room dimensions etc.) o When any kind of reports or complaints about possible overexposure have been made After the measurement assessment, the system will be in compliance with the limit values...
  • Page 21 PERSONAL PROTECTIVE EQUIPMENT (PPE): o Safety glasses with closed sides o Long-sleeved jersey, long trousers and closed-type shoes o Protective gloves o Face mask and hat and/or sunscreen (must contain either zinc oxide or titanium dioxide for face, neck and other areas where skin is exposed) Figure 3 Required protective equipment PPE National Institute for Occupational Safety and Health.
  • Page 22: Activities Prior To Performing The Assessment

    ACTIVITIES PRIOR TO THE ASSESSMENT Before installation, NORDICCO recommends that light sources are burned in for 100 hours, if possible. After the burn-in has been completed, the lamps will be stable and can be considered as a fixed starting point when starting to take the measurements. Failure to complete the 100- hour burn-in period may result in higher initial readings.
  • Page 23: Assessment And Measurement Instructions

    ASSESSMENT AND MEASUREMENT INSTRUCTIONS 1. Create a table with the required number of measuring grid-points, see assessment form Appendix F . The grid-points should be placed at equal distances from each other. See the figure and table below to determine the number of measuring grid-points: Length Maximum distance between Minimum...
  • Page 24 6. The measurement process is illustrated below in . Note objects that can influence the assessment Determine grid distance Prepare measurement tools, tripod etc. Secure the area. Lock doors / place warning sign Run the system for 10 minutes prior to Activate the UVC performing the measurements for the UVC light system...
  • Page 25: Picture Examples Of The Assessment Procedure

    PICTURE EXAMPLES OF THE ASSESSMENT PROCEDURE Below are picture examples of an assessment procedure with measurement equipment, as well as safety gear in the form of protective equipment. Figure 6: Setting the height of the sensor head to a standard 183 cm or acceptable height for the tasks that are performed in the room.
  • Page 26: Sensor Orientation

    SENSOR ORIENTATION The sensor is rotated 180 degree in each direction to The sensor is form a half sphere initially orientated towards the UVC system 183cm Figure 7: Examples of different sensor directions when measuring to locate hotspots.
  • Page 27: Mechanical Damping Of Uvc System

    MECHANICAL DAMPING OF UVC SYSTEM The system must be damped if irradiation intensities that exceed permitted values c.f. APPENDIX A – LIMIT VALUES FOR ARTIFICIAL OPTICAL IRRADIATION are registered during the assessment. Mechanical damping is done by replacing the glass/or aperture shield that covers the integrated UVC light sources with an aperture shield that blocks sufficient irradiation.
  • Page 28: Documentation And Deliveries

    DOCUMENTATION AND DELIVERABLES After activation, assessment and possible damping/calibration of the system, an assessment report must be prepared and made available to all involved parties. The report must at least contain the following information: o Inspection report A safety inspection must be performed if the UVC installer has not been responsible for the fan’s suspension and connection to ensure that the fan is installed correctly as set out in Part 1 of the installation procedure.
  • Page 29: The Assessment Form

    THE ASSESSMENT FORM Complete an assessment form to document the irradiation intensity in the room. The assessment form in its entirety can be found in APPENDIX F – ASSESSMENT FORM. Complete the form with the relevant information listed below: 1. Specify Address, Building Number and Room Number 2.
  • Page 30: User Instructions - Quick Guide

    USER INSTRUCTIONS – QUICK GUIDE BRIEF ABOUT NORDICCO CONTROLLER To control the Northern Light fan using the Nordicco Controller, see separate manual. The ® controller manual contains information about how to activate the Northern Light function, link fans to the tablet, along with setting up schedules, admin codes, names etc. It is highly recommended that both the controller manual and this installation manual is archived by the building administrator.
  • Page 31: Appendix Overview

    APPENDIX OVERVIEW APPENDIX A – LIMIT VALUES FOR ARTIFICIAL OPTICAL IRRADIATION APPENDIX B – CALCULATION EXAMPLE APPENDIX C – REFLECTIVITY FACTORS APPENDIX D – ELECTRICAL DIAGRAM APPENDIX E – DECLARATION OF CONFORMITY APPENDIX F – ASSESSMENT FORM...
  • Page 32: Appendix A - Limit Values For Artificial Optical Irradiation

    APPENDIX A – LIMIT VALUES FOR ARTIFICIAL OPTICAL IRRADIATION When calibrating the system, the limit values specified in EN 62471 Photobiological safety of lamps and lamp systems must be observed. Table 2 states the maximum permitted limit values for the Northern Light System, calculated on the basis of EN 62471. The same limit values are specified in the UE Directive 2006/25/EC - artificial optical radiation and its requirements will therefore also be satisfied if these limit values are complied with.
  • Page 33: Appendix B - Calculation Example

    APPENDIX B – CALCULATION EXAMPLE CODES AND STANDARDS The calculation has been prepared on the basis of the following codes, standards and directives: • EN 62471 (2008-09-29) - Photobiological safety of lamps and lamp systems • EU Directive, 5 April 2006: Artificial Optical Radiation Directive (2006/25/EC) CALCULATIONS ASSUMPTIONS USED IN CALCULATIONS The system uses 5 TUV PL-L 60W/4P HO 1CT/25 low pressure lamps mounted as up-lights in...
  • Page 34 FORMULAE The calculation is performed in accordance with the instructions in EN 62471 and is based on formula (4.1). %& ( ', # ) ∙ * ( ' ) ∙ ∆# ∙ ∆' ≤ 30 0 ∙ 1 ∙ # = % % ! "...
  • Page 35 Formula 4.2. c.f. EN 61471 can thus also be rewritten as: L where t is maximum exposure time and E is irradiation intensity CALCULATION EXAMPLE Based on the described formula 4.2, maximum exposure time can now be calculated at different irradiation intensities. The following is an example where the measured irradiation in the room is measured to E %&...
  • Page 36: Appendix C - Reflectivity Factors

    APPENDIX C – REFLECTIVITY FACTORS Reflectivity factors for common materials Table 3 and Table 4 specify reflectivity values for common materials. The values in some cases cover both UVB and UVC wavelengths and must therefore be considered to be indicative. Material Reflection (%) Untreated aluminium surface...
  • Page 37 Reflectivity factors for common ceiling panels Table 5 and Table 6 indicate reflection values for common ceiling panels. The reflection values should be considered indicative. The reflection values have been prepared on the basis of the 254nm low-pressure lamp. The reflection values originate from: Reed NG, Wengraitis S, “Ultraviolet Spectral Reflectance of Ceiling Tiles, and Implications for the Safe Use of Upper-Room Ultraviolet Germicidal Irradiation”...
  • Page 38 Ceiling panels Table 6 Ceiling panel categories, See Table 5 for reflection values: Please note: All panels are white unless otherwise indicated in parentheses next to the model or in the model name itself. ID is used to identify specific panels in diagrams, tables, and text. Product Obvious surface Supplier...
  • Page 39: Appendix D - Electrical Diagram

    APPENDIX D – ELECTRICAL DIAGRAM...
  • Page 40: Appendix E - Declaration Of Conformity

    APPENDIX E – DECLARATION OF CONFORMITY...
  • Page 41: Appendix F - Assessment Form

    APPENDIX F – ASSESSMENT FORM Only a professional UVC installer may perform the assessment. Complete this form after installation and calibration/damping of one or more NORDICCO Northern Light ® UVC systems. If more than one system is installed in the room in question, the measurement must be made while all systems are activated, so as to measure the total irradiation in the room.
  • Page 42 Room Maximum distance between Minimum Grid and measurement points Length measuring points (m). Height h measuring Room dimensions: L (m) in (m) (h > 3m) points Length, L (m) Width, W (m) 2-7,5m 0,35 * h . Max 2m Height, h (m) 7,5-15m 0,45 * h , max 3,5m 15-25m 0,55 * h , max 5m...
  • Page 43 DATE:________________________________ ARTIFICIAL OPTICAL RADIATION ASSESSMENT PERFORMED BY: THIS FORM MUST NOT BE COVERED OR REMOVED FROM THE ROOM Company_____________________Name______________________________ MEASUREMENTS: (Complete in block letters) Measuring Radiation Measuring Radiation Measuring Radiation point intensity point intensity point intensity (Location) (μW/cm (Location) (μW/cm (Location) (μW/cm Address, Building number and premises number: __________________________________________ The UVC system (ceiling fan) in this room has been calibrated and verified to the following intensity (254nm) in the occupancy zone.
  • Page 44 We are a Danish company, wanting to contribute towards the acceleration to a more sustainable economy. Nordicco designs and manufactures climate-friendly High Volume Low Speed (HVLS) fans and associated control systems. What we do Our solutions help our customers improve...