OWNER'S MANUAL
(Includes Operation, Maintenance, and Parts)
AURORA ASTRO SURGICAL LIGHTS
Read this manual before operating this light! This information is necessary for the safe
and efficient operation of the equipment.
TEC-B-0210 REV3
06/19/2019

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AURORA ASTRO and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Skytron AURORA ASTRO

  • Page 1 OWNER'S MANUAL (Includes Operation, Maintenance, and Parts) AURORA ASTRO SURGICAL LIGHTS Read this manual before operating this light! This information is necessary for the safe and efficient operation of the equipment. TEC-B-0210 REV3 06/19/2019...
  • Page 2 The base language for this document is ENGLISH. Any translations must be from the base language document. Printed copies are not controlled documents. Although current at the time of publication, SKYTRON'S policy of continuous development makes this manual subject to change without notice. If current manuals are required, contact your local SKYTRON representative or contact SKYTRON directly at the distribution addresses listed above.
  • Page 3: Table Of Contents

    6-5. Shutdown Procedure ......................16 SECTION 7. PORTABLE STAND LIGHT (AUA3S) ..............17 7-1. Introduction ........................17 7-2. Power Requirements ......................18 7-3. Prior to Operation ......................18 7-4. Operation .......................... 20 7-5. Shutdown .......................... 21 AURORA ASTRO OWNER'S MANUAL• REV3...
  • Page 4 SECTION 10. OPTICAL CHARACTERISTICS ................28 SECTION 11. ELECTROMAGNETIC EMISSIONS ..............29 SECTION 13. REPLACEMENT PARTS ..................33 11-1. Light Fixture Components ....................34 11-2. Portable Stand Light ......................35 SECTION 12. REVISION HISTORY ..................... 36 AURORA ASTRO OWNER'S MANUAL • REV3...
  • Page 5: Safety Information

    1-2. Safety Precautions mitigation measures such as re-orienting or The following is a summary of WARNINGS and relocating the Aurora Astro AUA3 Surgical CAUTIONS indicated in this manual. These Light or shielding the location. If an RF precautions are found throughout the manual communication device needs to be used where they are applicable.
  • Page 6 The design of the Aurora Astro Series light or glutaraldehyde based disinfectants. does not utilize internal user serviceable Staining, pitting, discoloration, diffuser parts. Service must be performed by...
  • Page 7 This is necessary to avoid the possibility of damage to the equipment. NOTICE Indicates important information not related to personal injury. The sterilizable positioning handle is provided for light positioning by sterile personnel. DO NOT allow contact with non-sterile personnel. AURORA ASTRO OWNER'S MANUAL• REV3...
  • Page 8: Section 2. Equipment Specifications

    Medical electrical equipment – Part 1: General illumination to any part of the patient's body. requirements for basic safety and essential The Aurora Astro AUA3 series surgical light is performance – ANSI/AAMI ES60601-1: 2005/ suitable for all types of surgical procedures.
  • Page 9: Equipment Labels And Specifications

    1A x 2 T1AH, 250V 38VA-51VA (21)YYYY-MM-XXXX 24V DC 1.4A 1A x 2 T1AH, 250V (21)YYYY-MM-XXXX Lights manufactured 1-1-2019 and after do not bear the CE mark and do not conform to the CE standard. AURORA ASTRO OWNER'S MANUAL• REV3...
  • Page 10: Label Symbols

    Equipotentiality: Indicates potential equalization terminal. 2-8. Model Identification Configuration Model Description Surgical lighting system consisting of one (1) 17.5" [444.5 mm] Aurora Astro Portable Stand AUA3S AUA3 center focus lighthead mounted on a portable stand with locking casters. Ceiling-mounted radial support arm for one (1) 17.5" [444.5 mm] diameter Aurora Astro AUA3 lighthead. This model can be configured with extended...
  • Page 11: Section 3. Information For Service Personnel

    Servicing of the product must be performed according to the service manual instructions provided in this manual. Use original Skytron parts only The safety, reliability, and performance of the equipment can only be ensured if Skytron original replacement parts and accessories are utilized. Modifications and unauthorized Unauthorized repairs, temporary repairs, or modifications are not repairs permissible and will void the product’s warranty.
  • Page 12: Section 4. Documentation Requirements And Information

    Requirements and tests – IEC 60601-1-2 (4th Ed. 2014-02). Copyright and labeling All information contained in this service manual are the intellectual property of Skytron and are protected by national and international laws for the protection of intellectual property. Duplication, reproduction, translation, microfilming storage – in either electronic or magnetic form – processing as...
  • Page 13: Section 5. Functional Check And Operator Instruction

    A functional check must be performed after completing installation and prior to placing into use. • The Skytron light must be tested and commissioned prior to clinical use. • Testing and commissioning is a documented process provided by an authorized Skytron representative and includes written confirmation by the customer.
  • Page 14: Section 6. Ceiling Mounted Lights

    Sterilizable postioning 360° Pitch 360° Pitch handle Figure 1. Light Fixture Rotation Capabilities – Two Light Configuration (AUA33) Shown Aurora Astro AUA3 lightheads have a removable steriliziable positioning handle with an integrated intensity level adjustment control. This allows all final adjustments or changes to be precisely controlled by the surgeon from the sterile field. AURORA ASTRO OWNER'S MANUAL • REV3...
  • Page 15: Electrical Requirements

    Page 13 6-2. Electrical Requirements 6-3. Visual Checks Prior to Start-Up SKYTRON Aurora Astro AUA3 Series Surgical Lights require that electrical connections are CAUTION made by a licensed electrician in accordance Always inspect product prior to use to with local, State, and National electrical codes ensure safe and correct operation.
  • Page 16: Operating The Light

    Always examine the handles for wear or damage to ensure proper and safe operation with the surgical light. Figure 2. Sterilizable Positioning Handle – Push... Figure 3..Twist, then pull to lock in place. AURORA ASTRO OWNER'S MANUAL • REV3...
  • Page 17 If using the button at the center of the fixture to the desired intensity. The lighthead has positioning handle, press and hold for about 5 4 intensity settings and OFF. seconds to turn the light off. From OFF, the first press of the button will turn on the light fixture at the maximum intensity Lighthead intensity control button on ON (Max Level) positioning handle AURORA ASTRO OWNER'S MANUAL• REV3...
  • Page 18: Shutdown Procedure

    Such applications are at the discretion of the user to ensure patient safety. ON (Max Level) 2. Return the lighthead to its fully raised position. AURORA ASTRO OWNER'S MANUAL • REV3...
  • Page 19: Section 7. Portable Stand Light (Aua3S)

    7-1. Introduction The Model AUS3S Portable Stand Light consists includes continuous 360° rotation at the pitch of a single Aurora Astro Series lighthead and roll axis points. Ninety degrees vertical mounted on a portable stand. The lighthead travel is provided at the support post. Cord wrap...
  • Page 20: Power Requirements

    Page 18 The base contains the power cord, safety fuses, 7-2. Power Requirements main switch and equipotential terminal. The Aurora Astro portable stand-mounted light requires a properly grounded 100-240VAC, Equipotentiality terminal 50/60Hz electrical power supply. The stand is equipped with a 13 foot (4 m) long, 16-3 SJT power cord with a hospital grade plug.
  • Page 21 Exercise caution when moving the stand light to avoid obstacles, such as power cords or other items, in the pathway. DO NOT transport over rugged or unstable flooring that may damage the casters. AURORA ASTRO OWNER'S MANUAL• REV3...
  • Page 22: Operation

    Protective earth ground and equalization shall meet the requirements of state, local and national rules, standards and guidelines. AURORA ASTRO OWNER'S MANUAL • REV3...
  • Page 23: Shutdown

    2. Set the main power switch on the handle. Such applications are at the base in the OFF position. discretion of the user to ensure patient safety. SECTION 8. MAINTENANCE AURORA ASTRO OWNER'S MANUAL• REV3...
  • Page 24: Cleaning And Disinfecting

    Page 22 8-1. Cleaning and Disinfecting It is required practice to maintain the appearance 2. Avoid using spray cleaners. Avoid the and function of your Aurora Astro Series lighting application of cleaners using methods fixture with daily cleaning practices. Moving that produce extreme saturation. parts and their respective finishes will perform...
  • Page 25: Sterilization

    8-4. Operator Maintenance wipe containing clear water to remove residue and prevent staining. CAUTION 8-2. Sterilization The design of the Aurora Astro Series The sterilizable positioning handles are lighting fixture does not utilize internal constructed of heat-resistant, impact-resistant user-serviceable parts. Service must plastic.
  • Page 26 Support post is securely in place Balance arm and support post connection is tight Base and support post hardware is secure Power cord is undamaged. If damaged, replace before use. Positioning handles are tight and undamaged AURORA ASTRO OWNER'S MANUAL • REV3...
  • Page 27: Troubleshooting

    Corrective actions requiring When attempting to troubleshoot a light light fixture repairs, replacement, and adjustment malfunction, first determine if the malfunction is electrical or mechanical, then use the must be performed by SKYTRON authorized service technicians. appropriate chart to help determine the cause 8-5-1. Operator Troubleshooting Guide...
  • Page 28: Maintenance Procedures

    Avoid use of the light fixture if the life expectancy will result in diminished diffuser lens assembly or main housing illuminance values, reducing intensity and are physically damaged. affecting color temperature. AURORA ASTRO OWNER'S MANUAL • REV3...
  • Page 29: End Of Useful Life And Disposal

    • Inspect positioning handles on support post 8-9. End of Useful Life and Disposal The end of the useful life for the SKYTRON surgical light is 10 years under normal operating conditions. Service parts are available for this period. Please contact your SKYTRON authorized...
  • Page 30: Section 9. Optional Accessories

    527 mm Illuminance at 1 meter distance from light source without obstruction. is the measure of radiant power over a specified area It is expressed in watts per square meter [W/m D iameter of a circle around the light field center (point of Illuminance) where the Illuminance reaches 10% of E D iameter of a circle around the light field center (point of Illuminance) where the Illuminance reaches 50% of E AURORA ASTRO OWNER'S MANUAL • REV3...
  • Page 31: Section 11. Electromagnetic Emissions

    EMC for therefore, can interfere with the functionality the Aurora Astro AUA3 Light. of the Aurora Astro AUA3 Light. The Aurora • The Aurora Astro AUA3 Light needs special Astro AUA3 Light should not be used adjacent precautions regarding EMC and needs to be to or stacked with other equipment.
  • Page 32 Page 30 Guidance and Manufacturer’s Declaration – Electromagnetic Emissions The Aurora Astro AUA3 Light is intended for use in the electromagnetic environment specified below. The customer or the user of the Aurora Astro AUA3 Light should assure that it is used in such an environment. Emissions test Compliance Electromagnetic environment – guidance The Aurora Astro AUA3 Light uses RF energy only for its internal RF Emissions –...
  • Page 33 Page 31 Guidance and Manufacturer’s Declaration – Electromagnetic Immunity The Aurora Astro AUA3 Light is intended for use in the electromagnetic environment specified below. The customer or the user of the Aurora Astro AUA3 Light should assure that it is used in such an environment. EN/IEC 60601 Intended Electromagnetic Immunity Test Compliance Level Environment Test Level...
  • Page 34 Page 32 Guidance and Manufacturer’s Declaration – Electromagnetic Immunity (Cont'd) The Aurora Astro AUA3 Light is intended for use in the electromagnetic environment specified below. The customer or the user of the Aurora Astro AUA3 Light should assure that it is used in such an environment. EN/IEC 60601 Intended Electromagnetic Immunity Test Compliance Level Environment...
  • Page 35: Section 13. Replacement Parts

    Page 33 SECTION 13. REPLACEMENT PARTS NOTICE Aurora Astro surgical light replacement parts listed in this section have been identified by The following abbreviations are used in this SKYTRON as serviceable by facility personnel section: and are available for purchase. To obtain • AR = As Required SKYTRON certified parts and authorized •...
  • Page 36: Light Fixture Components

    Qty. B9-210-44-1 CEILING COVER ....................... 1 B2-410-12 COVER, rubber ....................... AR B4-341-06 COVER, side ........................2 B4-341-14 COVER, yoke ........................1 B1-710-49-C HANDLE, sterilizable positioning handle ................1 B2-720-58 COVER, assembly, hub ..................... 1 AURORA ASTRO OWNER'S MANUAL • REV3...
  • Page 37: Portable Stand Light

    HANDLE, stand maneuvering handle ................2 B4-242-45 HOOK, cord ........................2 B9-611-22 COVER, base ........................4 B9-715-32 CASTER, locking ....................... 4 B4-242-50 WASHER, lock ........................4 B4-442-64 FUSE, 1A, timelag ......................2 B1-810-71 CORD, power ........................1 AURORA ASTRO OWNER'S MANUAL• REV3...
  • Page 38: Section 12. Revision History

    Pg 8: Updated the light measurements to 17.5" 06/19/2019 Removed CE from cover page Inner cover page and Pg 7 added "Lights manufactured 1-1- 2019 and after do not bear the CE mark and do not conform to the CE standard." AURORA ASTRO OWNER'S MANUAL • REV3...
  • Page 39 Page 37 NOTES AURORA ASTRO OWNER'S MANUAL• REV3...
  • Page 40 Page 38 NOTES AURORA ASTRO OWNER'S MANUAL • REV3...
  • Page 41 Page 39 NOTES AURORA ASTRO OWNER'S MANUAL• REV3...
  • Page 42 5085 Corporate Exchange Blvd. S.E. Grand Rapids, MI 49512 • 616.656.2900 • FAX 616.656.2906...