Page 1
Wasp DuraLine 2D Imager Dura Q u i c k R e f e r e n c e G u i d e...
Page 2
An Unpublished Work - All rights reserved. No part of the contents of this documenta- tion or the procedures described therein may be reproduced or transmitted in any form or by any means without prior written permission of WASP Technologies or its wholly owned subsidiaries. Owners of WASP products are hereby granted a non-...
FCC Class B Compliance Statement ... ii-3 Canadian Notice ... ii-3 Power Supply ... ii-3 Solids and Water Protection ... ii-3 Wasp Bar Code Technologies ... ii-4 SOFTWARE LICENSE AGREEMENT ... ii-4 Software Product Policy ... ii-6 Customers Under Software Support ... ii-6 Chapter 1 Getting Started ...1-1...
Page 4
Chapter 3 Customer Support ... 3-1 Customer SupportTechnical Support ...3-1 WASP Website Support ...3-1 Telephone Technical Support ...3-1 Standard Warranty ...3-2 Exclusions ...3-2 Limitations of Liability ...3-3 Assignment ...3-3 Risk of Loss ...3-3 DuraLine™ 2D Imagers...
Statement of Agency Compliance This device complies with part 15 of the FCC Rules. Operation is subject to the follow- ing two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
WARE PRODUCT AND YOU WILL RECEIVE A REFUND OF YOUR MONEY. THIS LICENSE AGREEMENT REPRESENTS THE ENTIRE AGREEMENT CONCERNING THE SOFTWARE PRODUCT BETWEEN YOU AND WASP BAR CODE TECHNOLOGIES, including its licensors (REFERRED TO AS "LICENSOR"), AND IT SUPERSEDES ANY PRIOR PROPOSAL, REPRESENTATION, OR UNDERSTANDING BETWEEN THE PAR- TIES.
Page 7
The entire risk as to use of the SOFTWARE is assumed by you. 7. Trademark. Wasp and Wasp Bar Code Technologies are trademarks of Licensor. All other trade- marks are those of third parties or licensors. No right, license, or interest to such trademarks are granted hereunder, and you agree that no such right, license, or interest shall be asserted by you with respect to such trademarks.
This provides our customers with the very latest in WASP software technology. The only exception to this policy is when the buyer has a signed contract with WASP that clearly defines the terms and conditions for making software/firmware changes in products shipped to the buyer.
Getting Started Unpacking the Imager After you open the shipping carton containing the Imager, take the fol- lowing steps: • Check to make sure everything you ordered is present. • Save the shipping container for later storage or shipping. • Check for damage during shipment.
Figure 1-2. Aiming Beam Positioning Linear bar code 2D Matrix symbol The aiming beam is smaller when the Imager is closer to the code and larger when it is farther from the code. Symbologies with smaller bars or elements (mil size) should be read closer to the unit.
Plug and Play Plug and Play bar codes provide instant Imager set up for commonly used interfaces. After you scan one of the codes, power cycle the host terminal to have the interface in effect. NOTE Connecting the Imager with an RS- 232 Serial Port These instructions are for use with the RS-232 cable.
This interface applies to USB compatible mod- els only. NOTE An Imager can be connected to the USB port of a computer. 1. Connect the appropriate interface cable to the Imager and to the computer. RS-232 Interface DuraLine™ 2D Imagers...
NOTE For additional USB programming and technical information, visit the WASP website listed on the back cover of this manual. IBM SurePos Scan one of the following “Plug and Play” codes to program the Imager for IBM SurePos (USB Hand Held Imager) or IBM SurePos (USB Tabletop Imager).
Scan the following code to program the Imager for USB HID bar code Imagers. Scanning this code changes the terminal ID to 131. Symbology Suffix 00 0A 0B 00 0D 0B 00 18 0B Keyboard ® USB HID Bar Code Imager DuraLine™ 2D Imagers USB Keyboard (Mac)
Resetting the Standard Product Defaults Resetting the Standard Product Defaults If you aren’t sure what programming options are in your imager, or you’ve changed some options and want the factory settings restored, scan the Standard Product Default Settings bar code below. See the Product Reference Guide (PRG) for more information about factory default set- tings.
Page 16
Getting Started NOTES DuraLine™ 2D Imagers...
Repairs Repairs and/or upgrades are not to be performed on this product. These services are to be performed only by an authorized service center. See the Product Reference Guide for further information. Maintenance The Imager provides reliable and efficient operation with a minimum of care.
Inspect the Imager’s interface cable and connector for wear or other signs of damage. A badly worn cable or damaged connector may interfere with Imager operation. Contact your WASP dealer for information about cable replacement. Cable replacement instructions are included below.
Connecting the I/F Cable DO NOT try to pull the End Cap off, as this may damage the scanner CAUTION 1. Connect the I/F cable to the appropriate connection on the host terminal. Consult your host terminal manual if you’re unsure of the correct port.
The Imager may not be programmed to output your bar code data properly. For example, you scan “12345” and the host displays “A12345B.” Reprogram the Imager with the proper symbology selections. See the Product Reference Guide. and/or the Product Reference Chapter 1 DuraLine™ 2D Imagers...
The Imager won’t read your bar code at all. 1. Scan the part number bar code in the back of this manual or the samples from the Product Reference Guide. If the Imager reads sample bar codes, check that your bar code is readable. Verify that your bar code symbology is enabled (see the Product Reference Guide).
WASP Knowledgebase, product support, product registration, warranty information, product manuals, software updates, demos, and instruc- tions for returning products for repair. Telephone Technical Support If you do not have internet or email access, you may contact WASP tech- nical support at (214) 541-4100. Quick Reference Guide...
In order to obtain service under this Warranty, Customer must notify WASP of the claimed defect before the expiration of the Warranty period and obtain from WASP a return authorization number for return of the product to designated WASP service center. If WASP determines Cus- tomer’s claim is valid, WASP will repair or replace product without addi-...
Standard Warranty Limitations of Liability WASP repair or replacement of defective product as set forth above is the customer's sole and exclusive remedy on account of claims of breach of warranty or product defect. Under no circumstances will WASP be lia-...
Page 26
Customer Support NOTES DuraLine™ 2D Imagers...
Page 27
DECLARATION OF CONFORMITY Wasp Technologies hereby declares that the equipment specified below has been tested and found compliant to the following directives and standards. EU Directives: 89/336/EEC EMC 73/23/EEC Low Voltage 2002/95/EC Hazardous Substance 2003/11/EC Hazardous Substance 94/62/EC Packaging Standards...