(4) Data
There are six types of EEPROM data. Each data is displayed in different color on the EEPROM Utility screen.
Color
Light blue
Fixed data
Pink
Adjusting data
Light green
No Fixed data
Orange
Default setting data
Dark magenta
Doctor data
Yellow
PE data
5.6.5 Temperature information
(1) On the SSS main screen, click [Option]-[About Temperature (OP)] to check the internal temperature (internal temperature near
OP).
• The CCD needs to be fully warmed up for white blemish correction. The internal temperature of the unit (the temperature near
OP) must be 47.5°C or higher (43h or less).
Check the internal temperature in About Temperature (OP).
5.6.6 Non-communication mode
In the non-communication mode, The SSS can be used without connecting the unit. The EEPROM saved in the disk can be checked.
(1) On the "Serial Port Configuration" screen in starting the SSS, press and hold the "L" key on the keyboard, then click [OK].
(2) A warning screen appears, click [OK].
Type
Data that not change by CPU.
Data that is changed by adjustment.
Data that may be changed by CPU.
Data that is changed by usage.
Data that not change.
Data that not change.
Press and hold, then click
Description
Model code, etc.
Adjustment data.
Focus/Zoom position memory, etc.
Menu setting, emergency, etc.
Doctor program.
Data that is used during production.
Before correcting white blemish,
check that the internal
temperature is 47.5 C or higher.
(EEPROM data:43h or less)
Details
(No.HC044<Rev.001>)1-33