JOYTECH DBP-6281L Owner's Manual

JOYTECH DBP-6281L Owner's Manual

Arm-type fully automatic digital blood pressure monitor

Advertisement

Quick Links

Owner's Manual
Arm-type Fully Automatic
Digital Blood Pressure Monitor
DBP-6281L
Model
Arm Type
Arm Type
Contents
Safety Notice ...............................................................
Unit Illustration .........................................................
Important Testing Guidelines ..................................... 09
Quick Start ................................................................. 10
Unit Operation ...........................................................
Battery Installation ...........................................
System Settings .................................................. 12
Applying the Arm Cuff ....................................... 14
Testing ................................................................ 15
Power Off .............................................................17
Memory Check and Last 3 Test Average
Memory Deletion ..................................................19
Low Battery Indicator ...........................................19
Bluetooth requirement and connection ...............20
Troubleshooting .....................................................22
Blood Pressure Information ........................................ 23
Maintenance ............................................................... 27
Specifications ............................................................. 29
Warranty .................................................................... 31
...................................................
Contact Information
The lay operator or lay responsible or ganization should contact
the manufacturer or the representative of manufacturer.
-for assistance,if needed,in setting up,using or maintaining
the product,or
-to report unexpected operation or events.
Manufactured by JOYTECH Healthcare Co.,Ltd.
No.365, Wuzhou Road,Yuhang Economic Development Zone,
Hangzhou City,311100 Zhejiang,China
Email: info@sejoy.com
Telephone: +86-571-81957767
Fax: +86-571-81957750
1
Safety Notice
02
Thank you for purchasing the DBP-6275B Blood Pressure Monitor. The unit has been constructed
using reliable circuitry and durable materials. Used properly, this unit will provide years of
06
satisfactory use.
Indications for use: The Arm-type Fully Automatic Digital Blood Pressure monitors are
intended to measure blood pressure(systolic and diastolic) and pulse rate of adults and
adolescents over 12 years of age.
11
All functions can be used safely and values can be read out in one
LCD DISPLAY. Measurement position is on adult upper arm only.
11
The PATIENT is an intended OPERATOR
Blood pressure measurement determined with this device are equivalent to those obtained
by a trained observer using the cuff/ stethoscope auscultation method, within the limits
prescribed by the Recognized Consensus Standard (IEC 80601-2-30) for electronic
sphygmomanometers.
.............18
Precautions to Ensure Safe, Reliable Operation
1. Do not drop the unit. Protect it from sudden jars or shocks.
2. Do not insert foreign objects into any openings.
3. Do not attempt to disassemble the unit.
4. Do not crush the pressure cuff.
5. If the unit has been stored at temperatures below 0 ℃, leave it in a warm place for
about 15 minutes before using it. Otherwise, the cuff may not inflate properly.
6. If the unit has been stored at temperatures above 40 ℃, leave it in a cool place for about
15 minutes before using it. Otherwise, the cuff may not inflate properly.
7. Do not store the unit in direct sunlight, high humidity or dust.
8.To avoid any possibility of accidental strangulation, keep this unit away from children
and do not drape tubing around your neck.
9.Ensure that children do not use the instrument unsupervised; some parts are small
enough to be swallowed.
10.Some may get a skin irritation from the cuff taking frequent readings over the course
of the day, but this irritation typically goes away on its own after the monitor is removed.
37
Document No. : JDBP-8104-076
Version: A
Date of Issue:2020.09.26
2

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DBP-6281L and is the answer not in the manual?

Questions and answers

Summary of Contents for JOYTECH DBP-6281L

  • Page 1: Table Of Contents

    -for assistance,if needed,in setting up,using or maintaining the product,or -to report unexpected operation or events. Manufactured by JOYTECH Healthcare Co.,Ltd. No.365, Wuzhou Road,Yuhang Economic Development Zone, Hangzhou City,311100 Zhejiang,China Email: info@sejoy.com Telephone: +86-571-81957767...
  • Page 2: Safety Notice

    Bluetooth SIG, 20. The system might produce incorrect readings if stored or used outside the manufacturer's Inc. and any use of such marks by JOYTECH Healthcare Co.,Ltd. specified temperature and humidity ranges. Make sure to store the blood pressure monitor, 21 indicate dust proof and waterproof grade.
  • Page 3: Important Testing Guidelines

    Irregular Heartbeat Indicator Contents Owner's Manual Arm-type Fully Automatic Digital Blood Pressure Monitor DBP-6281L Model Any blood pressure recording can be affected by the following factors: Arm Type 1. The position of the subject, his or her physiologic condition; 2. The performance and accuracy of the device;...
  • Page 4: System Settings

    Unit Operation Unit Operation 3. Time Format setting System Settings Press "GROUP1" button or "GROUP2" button again to set the time format setting mode. Set the time format by adjusting the“MEM” button. EU means European Time With power off, press "GROUP1" button or "GROUP2"...
  • Page 5: Power Off

    Unit Operation Unit Operation 2. Testing Irregular Heartbeat Indicator After cuff inflation, air will slowly rise as indicated by the corresponding cuff pressure If the monitor detects an irregular heart rhythm two or more times during the measuring value. A flashing " "...
  • Page 6: Troubleshooting

    Unit Operation Unit Operation Static Pressure Measurement Bluetooth requirements In the power down state, press and hold the " START/STOP" button, and then install Wireless communication The monitor requires a device with: Frequency range : 2.4 Ghz (2400-2483.5 MHz) the batteries. Until the LCD screen is full, release the " START/STOP" button. .
  • Page 7: Blood Pressure Information

    WHO Blood Pressure Classification Indicator Blood Pressure The DBP-6281L is equipped with a classification indicator based on established guidelines from the World Health Organization. The chart below (color coded on monitor unit) Blood pressure is the force of blood pushing against the walls of arteries. It is typically indicates test results.
  • Page 8: Maintenance

    ℉ ℉ Product Description Arm-type Fully Automatic Blood Pressure Monitor ~ 40 (50 ~104 ) 0℃ 15% ~ 93%RH Humidity Operating Environment DBP-6281L Model Pressure 800hPa~1060hPa Display LCD Digital Display Size:94mm x 90.6mm(3.7" x 3.57") ℉ ℉ ℃ ℃ Temperature:...
  • Page 9: Warranty

    Warranty Electromagnetic Compatibility Information The Blood Pressure Monitor is guaranteed for 2-year from the date of purchase. If the The device satisfies the EMC requirements of the international standard IEC Blood Pressure Monitor does not function properly due to defective components or poor 60601-1-2.
  • Page 10 Electromagnetic Compatibility Information Electromagnetic Compatibility Information Table 3 Table 4 Guidance and declaration of manufacturer-electromagnetic immunity Recommended separation distances between portable and mobile RF communications equipment and the device Nowadays, many RF wireless equipments have being used in various healthcare The device is intended for use in an electromagnetic environment in which locations where medical equipment and/or systems are used.
  • Page 11: Additional Notes

    Additional Notes Correct Disposal of This Product (Waste Electrical & Electronic Equipment) This marking shown on the product indicates that it should not be disposed with other household waste at the end of its life. To prevent potential harm to the environment or to human health, please separate this product from other types of wastes and recycle it responsibly.

Table of Contents