JOYTECH DBP-6275B Owner's Manual

JOYTECH DBP-6275B Owner's Manual

Arm-type fully automatic digital blood pressure monitor

Advertisement

Quick Links

Owner's Manual
Arm-type Fully Automatic
Digital Blood Pressure Monitor
DBP-6275B
Model
Arm Type
Contents
Safety Notice ...............................................................
Unit Illustration .........................................................
Important Testing Guidelines ..................................... 08
Quick Start ................................................................. 09
Unit Operation ...........................................................
Battery Installation ..................................................
System Settings ........................................................
.............................................
.....................................................................
................................................................
and Last 3 Test Average
Memory Check
.....................................................
.............................................
Bluetooth requirement and connection
...................................................
Blood Pressure Information ........................................ 23
Maintenance ............................................................... 27
Specifications ............................................................. 29
Warranty .................................................................... 31
Contact Information
The lay operator or lay responsible or ganization should contact
the manufacturer or the representative of manufacturer.
-for assistance,if needed,in setting up,using or maintaining
the product,or
-to report unexpected operation or events.
Manufactured by JOYTECH Healthcare Co.,Ltd.
No.365, Wuzhou Road,Yuhang Economic Development Zone,
Hangzhou City,311100 Zhejiang,China
Email: info@sejoy.com
Telephone: +86-571-81957767
Fax: +86-571-81957750
1
Thank you for purchasing the DBP-6275B Blood Pressure Monitor. The unit has been constructed
02
using reliable circuitry and durable materials. Used properly, this unit will provide years of
satisfactory use.
06
Measure blood pressure(systolic and diastolic)and pulse rate of adults and adolecents age
12 through 21years of age. All functions can be used safely and values can be read out in one
LCD DISPLAY. Measurement position is on adult upper arm only.
The PATIENT is an intended OPERATOR
10
Blood pressure measurement determined with this device are equivalent to those obtained
10
by a trained observer using the cuff/ stethoscope auscultation method, within the limits
11
prescribed by the Recognized Consensus Standard (IEC 81060-2-30) for electronic
sphygmomanometers.
13
14
Precautions to Ensure Safe, Reliable Operation
17
1. Do not drop the unit. Protect it from sudden jars or shocks.
...........................
18
2. Do not insert foreign objects into any openings.
3. Do not attempt to disassemble the unit.
19
4. Do not crush the pressure cuff.
19
5. If the unit has been stored at temperatures below 0 oC, leave it in a warm place for
..............
20
6. If the unit has been stored at temperatures above 40 oC, leave it in a cool place for about
22
7. Do not store the unit in direct sunlight, high humidity or dust.
8.To avoid any possibility of accidental strangulation, keep this unit away from children
9.Ensure that children do not use the instrument unsupervised; some parts are small
10.Some may get a skin irritation from the cuff taking frequent readings over the course
Safety Notice
about 15 minutes before using it. Otherwise, the cuff may not inflate properly.
15 minutes before using it. Otherwise, the cuff may not inflate properly.
and do not drape tubing around your neck.
enough to be swallowed.
of the day, but this irritation typically goes away on its own after the monitor is removed.
Document No.:
JDBP-7504-054
Version:Z
Date of Issue:2020.06
2

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DBP-6275B and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for JOYTECH DBP-6275B

  • Page 1: Table Of Contents

    Telephone: +86-571-81957767 Fax: +86-571-81957750 Contents Safety Notice Thank you for purchasing the DBP-6275B Blood Pressure Monitor. The unit has been constructed Safety Notice ............... using reliable circuitry and durable materials. Used properly, this unit will provide years of satisfactory use.
  • Page 2: Safety Notice

    21. Do not use the device near strong electrical or electromagnetic fields generated by cell registered trademarks owned by Bluetooth SIG, Inc. and any use of such marks by JOYTECH phones or other devices, they may cause incorrect readings and interference or become Healthcare Co.,Ltd.
  • Page 3: Important Testing Guidelines

    10. Do not use this blood pressure monitor if the device is damaged. Owner's Manual Arm-type Fully Automatic Digital Blood Pressure Monitor DBP-6275B Model Any blood pressure recording can be affected by the following factors: Arm Type 1. The position of the subject, his or her physiologic condition;...
  • Page 4: System Settings

    Unit Operation Unit Operation 2. Time/Date setting System Settings Press“SET” button again to set the Time/Date mode. Set the year first by adjusting the “MEM” button. With power off, press "SET" button to activate System Settings. The Memory Group icon Press“SET”...
  • Page 5: Testing

    Unit Operation Unit Operation 2. Testing After cuff inflation, air will slowly rise as indicated by the corresponding cuff pressure value. A flashing " " will appear simultaneously on screen signaling heart beat detection. Note: Do not insert air plug into opening located on right side of monitor unit. mmHg This opening is designed for an optional power supply only.
  • Page 6: Memory Deletion

    Unit Operation Unit Operation Memory Deletion Static Pressure Measurement Memory for a selected group may be deleted while in Memory Check mode. Press and hold In the power down state, press and hold the " START/STOP" button, and theninstall the " SET " button for approximately 3 seconds to delete all memory records from the selected group.
  • Page 7: Blood Pressure Information

    WHO Blood Pressure Classification Indicator Blood Pressure The DBP-6275B is equipped with a classification indicator based on established guidelines from the World Health Organization. The chart below (color coded on monitor unit) Blood pressure is the force of blood pushing against the walls of arteries. It is typically indicates test results.
  • Page 8: Maintenance

    Service and maintenance require parts, repair, technical support will be provided. Specifications Specifications Product Description Arm-type Fully Automatic Blood Pressure Monitor Operating Environment 800hPa~1060hPa Pressure ℉ ℉ DBP-6275B Temperature -25℃~55℃ (-13 ~131 Model Storage Environment ≤93% RH Humidity Display LCD Digital Display Size:118mm×65mm (4.65" x 2.56") ℉...
  • Page 9: Warranty

    Warranty Electromagnetic Compatibility Information The device satisfies the EMC requirements of the international standard IEC 60601-1-2. The requirements are satisfied under the conditions described in the The Blood Pressure Monitor is guaranteed for 2-year from the date of purchase. If the table below.
  • Page 10 Electromagnetic Compatibility Information Electromagnetic Compatibility Information Table 3 Table 4 Guidance and declaration of manufacturer-electromagnetic immunity Recommended separation distances between portable and mobile RF communications equipment and the device Nowadays, many RF wireless equipments have being used in various healthcare The device is intended for use in an electromagnetic environment in which locations where medical equipment and/or systems are used.

Table of Contents