Maintenance; Periodic Service - Little Giant 15SC-CIA-RF Owner's Manual

Sewage pump
Table of Contents

Advertisement

Available languages

Available languages

MAINTENANCE

Risk of severe injury or death by electrical shock, high
temperatures, or pressurized fluids.
• Always unplug the pump power cord in addition to removing the fuse or shutting off the circuit breaker before
working on the pump or switch.
• Let pump cool for a minimum of 2 hours before attempting to service. Submersible pumps contain oil that
becomes pressurized and hot under normal operating conditions.
Risk of damage to pump or other equipment.
• This unit is permanently lubricated. Oiling is not required. Do not open the sealed portion of the unit or remove
housing screws.
• Do not remove the motor housing cover, impeller, socket head cap screws, or seals. Warranty is void if the motor
housing cover, impeller, or seals have been removed. Repairs on the motor or impeller require special tools.

Periodic Service

Inspect and test the pump system condition and operation every three months—more frequently in
heavy use applications.
1. Remove power to the system.
2. Check the power cords and electrical outlet for damage or corrosion.
IMPORTANT: The unit must be replaced if the power cord is damaged.
3. Remove all debris (gravel, sand, floating debris, etc.) from the basin.
4. Check the pump system components (basin, pump, etc.) for any build-up (sludge, sediment, miner-
als, etc.) that would inhibit functionality of the components.
• If significant, remove build-up or replace affected components.
5. Confirm all flexible coupling hose clamps are fully tightened.
6. Refer to
"Operation" on page
Cleaning Impeller and Volute
1. Disconnect power to the pump.
2. Remove the four bolts and washers that hold the volute to the
motor housing.
3. Separate the volute from the motor housing.
IMPORTANT: Do not remove the motor housing bolts or
screws.
4. Clean the impeller and the volute passage.
IMPORTANT: Do not use strong solvents on the impeller.
5. Be sure the impeller turns freely.
6. Reattach the volute to the motor housing, securing it with the
bolts and washers.
5.
MAINTENANCE
Periodic Service
3
4
A-N652
2
7

Advertisement

Table of Contents
loading

Table of Contents