INTRODUCTION
EN
This instruction sheet provides you with the information required
to safely own and operate your Little Giant pump. Retain these
instructions for future reference.
The Little Giant pump you have purchased is of the highest quality
workmanship and material, and has been engineered to give you
long and reliable service. Little Giant pumps are carefully tested,
inspected, and packaged to ensure safe delivery and operation.
Please examine your pump carefully to ensure that no damage
occurred during shipment. If damage has occurred, please
contact the place of purchase. They will assist you in replacement
or repair, if required.
READ
THESE
INSTRUCTIONS
ATTEMPTING TO INSTALL, OPERATE, OR SERVICE YOUR
LITTLE GIANT PUMP. KNOW THE PUMP'S APPLICATION,
LIMITATIONS,
AND
POTENTIAL
YOURSELF AND OTHERS BY OBSERVING ALL SAFETY
INFORMATION.
FAILURE
INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/
OR PROPERTY DAMAGE!
DESCRIPTION
The 1-EUAA-MD is a magnetic drive aquarium pump. It is designed
for salt water or fresh water applications, and operates submerged
or in-line, in any position. This epoxy-encapsulated pump has a
1/2" OD inlet for in-line use and a screened inlet for submersible
use.
The pump head parts are made of glass-filled polypropylene, the
impeller shaft is ceramic, and the thrust washers are Rulon
impeller-driven magnet is uncoated, ceramagnet A (barium ferrite)-
type ceramic, and the O-ring seals are nitrile. The impedance-
protected motor is epoxy-encapsulated inside a glass-filled,
polyester case.
The 1-EUAA-MD can pump most mildly corrosive fluids such as
low concentrations of acids and alkalies in the pH range of 5 to 9.
SAFETY GUIDELINES
WARNING: To avoid possible electric shock, take special care
when using aquarium equipment.
NOTE: When using the 1-EUAA-MD for aquarium biological filter
applications, refer to the instructions and owners manual supplied
by the filter manufacturer.
Aquarium tank • Réservoir de
l'aquarium • Tanque del acuario
Filter • Filtre • Filtro
Pump • Pompe • Bomba
Power cord • Cordon
d'alimentation • Cable
de corriente
Drip loop • Boucle
d'égouttement • Bucle
para goteo
MAGNETIC DRIVE
AQUARIUM PUMP
MODEL
1-EUAA-MD
CAREFULLY
BEFORE
HAZARDS.
PROTECT
TO
COMPLY
WITH
IN-LINE • EN LIGNE • EN LÍNEA
If the pump shows any sign of abnormal water leakage, immediately
unplug it from the power source.
Do not operate the pump if its power cord or plug is damaged, if it
is malfunctioning, or if it is dropped or damaged.
Do not use to pump flammable or explosive fluids such as gasoline,
fuel oil, kerosene, etc. Do not use in explosive atmospheres. Pump
should be used with liquids compatible with pump component
materials.
Do not handle pump with wet hands or when standing on a wet or
damp surface, or in water.
Do not pull the pump out of the water by the power cord when the
pump is operating or connected to power source.
This pump is supplied with a grounding conductor and grounding-
type attachment plug. To reduce the risk of electric shock, be
certain that it is connected only to a properly grounded, grounding-
type receptacle.
The National Electric Code requires a ground fault circuit interrupter
(GFCI) be installed in the branch circuit supplying fountain
equipment, pools, etc.
In any installation where property damage and/or personal injury
might result from an inoperative or leaking pump due to power
outages, discharge line blockage, or any other reason, use a
backup system(s) and/or alarm.
Support the pump and piping when assembling and when
installed. Failure to do so can cause piping to break, pump to fail,
THESE
motor bearing failures, etc.
If the plug or outlet gets wet, DO NOT unplug the cord. Disconnect
the fuse or circuit breaker that supplies power to the outlet, then
unplug the cord and check for water in the receptacle.
Close supervision is necessary when any pump is used by or near
children.
Unplug the pump from the outlet when not in use, before removing
or installing parts, and before cleaning.
Never pull on the cord to remove the plug from outlet; grasp and
pull the plug.
J. The
®
Do not use the pump for anything other than its intendend use.
Do not install or store the pump where it will be exposed to
the weather or to temperatures below freezing. This can cause
cracking or distortion that can destroy the pump.
If the pump is mounted on a tank, ensure that it is securely
installed before operating it.
Read and observe all notices on the pump.
If an extension cord is necessary, use a cord with a proper rating.
A cord rated for fewer amperes or watts than the pump rating may
overheat. Carefully arrange the cord so that it will not be tripped
over or pulled.
Do not attempt repairs yourself. Return the pump to Little Giant or
an authorized service center.
Aquarium tank • Réservoir de
l'aquarium • Tanque del acuario
Filter • Filtre • Filtro
Pump • Pompe • Bomba
Power cord • Cordon
d'alimentation • Cable
de corriente
Drip loop • Boucle
d'égouttement • Bucle
para goteo
Figure 1
SUBMERGED • SUBMERGÉE • SUMERGIDA
1

Advertisement

Table of Contents
loading

Summary of Contents for Little Giant 1-EUAA-MD

  • Page 1 The Little Giant pump you have purchased is of the highest quality This pump is supplied with a grounding conductor and grounding- workmanship and material, and has been engineered to give you type attachment plug.
  • Page 2: Electrical Connections

    Conserver ces directives afin de pouvoir les consulter plus tard. mounted outlet, and create a drip loop (Figure 1) on the power Le produit Little Giant que vous avez acheté a été soigneusement cord. The drip loop is the part of the cord below the outlet (or fabriqué...
  • Page 3: Connexions Électriques

    (GFI) soit installé sur le circuit d’installation d’une fontaine, d’une piscine, etc. 1. La pompe 1-EUAA-MD est expédiée avec deux volutes : une Dans toute installation où des dommages ou des blessures volute en ligne et une volute lisse. À sa sortie d’usine, elle est peuvent résulter d’un mauvais fonctionnement des pompes ou...
  • Page 4 Esta hoja de instrucciones le proporciona la información requerida fuente de potencia. para tener y operar de forma segura su producto Little Giant. Esta bomba se suministra con un conductor a tierra y/o un Guarde las instrucciones para referencia futura.
  • Page 5: Conexiones Electricas

    5. Cerciórese de que el cable eléctrico se encuentre en buen estado y no tenga muescas ni cortes. 1. La 1-EUAA-MD está empacada con dos espirales: en línea y 6. Conecte el cable de corriente de la bomba a un tomacorriente liso.
  • Page 6 Figure 2 REPLACEMENT PARTS • LISTE DES PIÉCES DE RECHANGE • LISTA DE PARTES Item • Part No. • Nº Quantity • Repere • De Piece • No. Quantité • Artículo De Pieza Description • Description • Descripción Cantidad 902420 Screw, 8-18 x 1-1/4”...
  • Page 7: Limited Warranty

    L’acheteur n’aura pas d’autre recours. Pour nos clients option of Little Giant as the sole remedy of buyer. For our customers aux ÉTATS-UNIS (territoire continental seulement): Veuillez retourner in the CONTINENTAL UNITED STATES: Please return the defective l’article défectueux suffisamment affranchi à...
  • Page 8: Garantia Limitada

    Little Giant y éste será el único remedio ambiente. del comprador. Para nuestros clientes en los ESTADOS UNIDOS 6.

Table of Contents