This instruction sheet provides you with the information required
to safely own and operate your product. Retain these instructions
for future reference.
The product you have purchased is of the highest quality
workmanship and material, and has been engineered to give you
long and reliable service. This product has been carefully tested,
inspected, and packaged to ensure safe delivery and operation.
Please examine your item(s) carefully to ensure that no damage
occurred during shipment. If damage has occurred, please
contact the place of purchase. They will assist you in replacement
or repair, if required.
READ
THESE
INSTRUCTIONS
ATTEMPTING
TO
INSTALL,
YOUR PRODUCT. KNOW THE PRODUCT'S APPLICATION,
LIMITATIONS,
AND
POTENTIAL
YOURSELF AND OTHERS BY OBSERVING ALL SAFETY
INFORMATION.
FAILURE
INSTRUCTIONS COULD RESULT IN PERSONAL INJURY
AND/OR PROPERTY DAMAGE!
MODEL
LISTING
HP
14EH-CIM
UL
1/2
14EH-CIM
UL
1/2
14S-CIM
UL
1/2
14S-CIM
UL
1/2
16EH-CIM
UL
1
16S-CIM
UL
1
16S-CIM
UL
1
NR: Not recommended. Operation at these heads or below will result in motor overload, reduced pump life, and/or motor failure/damage.
PumpAgents.com - Click here for Pricing/Ordering
14S-CIM
16S-CIM
14EH-CIM
16EH-CIM
CAREFULLY
BEFORE
OPERATE,
OR
SERVICE
HAZARDS.
PROTECT
TO
COMPLY
WITH
THESE
Figure 1 - Dimensions
AMPS/
VOLTS
WATTS
5'
115
12.5/1450
NR
208-240
5.7/1275
NR
115
11.6/1100
130
208-240
4.6/1100
130
230
9.0/2200
NR
230
11.0/1900
180
200-208
11.0/2000
180
PumpAgents.com - Click here for Pricing/Ordering
Little Giant submersible 14S and 16S series sewage ejector
pumps and 14EH/16EH series effluent pumps are recommended
for use in basins or lift stations and are suitable for pumping
sewage, effluent, wastewater, and other non-explosive, non-
corrosive liquids.
Little Giant offers a complete line of float switches and liquid level
control systems for automatic operation, along with a complete
line of alarms, basins, covers, and check valves.
READ ALL INSTRUCTIONS AND SAFETY GUIDELINES
THOROUGHLY. FAILURE TO FOLLOW THE GUIDELINES AND
THE INSTRUCTIONS COULD RESULT IN SERIOUS BODILY
INJURY AND/OR PROPERTY DAMAGE.
WARNING: RISK OF ELECTRIC SHOCK. This pump is supplied
with a grounding conductor and/or grounding type attachment
plug. To reduce the risk of electric shock, connect it only to a
properly grounded, grounding-type receptacle.
If this pump is equipped with a 3-prong electrical plug, the third
prong grounds the pump to prevent possible electrical shock
hazard. Do not remove the third prong from the plug. A separate
branch circuit is recommended. Do not use an extension cord.
When the pump is in a basin, sump, lift station, etc., do not touch
the motor, pipes, or water until the pump is unplugged or shut off.
If your installation has water or moisture present, do not touch the
wet area until all power has been turned off. If the shut-off box is
not accessible, call the electric company to shut off service to the
GALLONS PER MINUTE @ FEET OF HEAD
10'
20'
30'
40'
50'
--
NR
60
40
20
--
NR
60
40
20
--
--
--
100
35
--
--
--
100
35
NR
NR
90
70
50
--
--
160
100
40
--
--
160
100
40
DESCRIPTION
SAFETY GUIDELINES
WARNING
POWER
CORD
60'
SHUT-OFF P.S.I.
(ft.)
--
50'
21.6
20
--
50'
21.6
20
--
25'
10.8
20
--
25'
10.8
20
30
81'
35.1
20
--
35'
15.1
20
--
35'
15.1
20
WEIGHT
(lbs.)
74
74
80
80
82
88
88
1