Vulcan-Hart VL2EAS Service Manual page 35

Vl boiler base series convection steamers
Hide thumbs Also See for VL2EAS:
Table of Contents

Advertisement

VL SERIES STEAMER - SERVICE PROCEDURES AND ADJUSTMENTS
TOTAL
VOLTAGE
KW
ELEMENTS
208
18
240
18
480
18
*220/380
18
240/415
208
24
240
24
480
24
*220/380
24
240/415
208
36
240
36
480
36
*220/380
36
240/415
208
42
240
48
480
48
*220/380
48
240/415
NOTES:
1.
Values in the table are nominal. Tolerance is +/-10 %.
2.
Asterisk (*) indicates 3 phase/4wire.
3.
Each heater has three internal elements.
NUMBER
KW
OF
PER
ELEMENT
2
9
2
9
2
9
2
9
2
12
2
12
2
12
2
12
4
9
4
9
4
9
4
9
4
10.5
4
12
4
12
4
12
Page 35 of 88
AMPERAGE
RESISTANCE
PER LINE
PER
ELEMENT
1 PH
3 PH
(OHMS)
87
50
14.42
75
44
19.20
22
76.80
25
19.20
116
68
10.82
100
58
14.40
29
57.60
34
14.40
100
14.42
87
19.20
44
76.80
50
19.20
117
12.36
116
14.40
58
57.60
67
14.40

Advertisement

Table of Contents
loading

Table of Contents