Boiler Assembly; High Limit Thermostat - Vulcan-Hart VL2EAS Service Manual

Vl boiler base series convection steamers
Hide thumbs Also See for VL2EAS:
Table of Contents

Advertisement

VL SERIES STEAMERS - REMOVAL AND REPLACEMENT OF PARTS

BOILER ASSEMBLY

WARNING: DISCONNECT THE ELECTRICAL
POWER TO THE MACHINE AT THE MAIN
CIRCUIT BOX. PLACE A TAG ON THE CIRCUIT
BOX INDICATING THE CIRCUIT IS BEING
SERVICED.
WARNING: SHUT OFF THE GAS BEFORE
SERVICING THE UNIT.
WARNING: ALL GAS JOINTS DISTURBED
DURING SERVICING MUST BE CHECKED FOR
LEAKS. CHECK WITH A SOAP AND WATER
SOLUTION (BUBBLES). DO NOT USE AN OPEN
FLAME.
1.
Blow down the boiler and allow to cool, if
necessary.
2.
Ensure that all utilities to the steamer are off
and disconnected. Drain any excess water from
the boiler.
3.
Disconnect the steam supply line, power leads
and drain lines from the cooking compartment
top to the boiler base.
4.
Disconnect all plumbing connections and power
leads from the components inside the control
boxes that would obstruct the removal of the
boiler through the front of the base, then
remove those control boxes.
5.
Disconnect the remaining plumbing and
electrical connections from the boiler to the
controls.
6.
Remove the screws holding the flue and flue
collector to the base.
7.
Remove the anchor screws holding the boiler to
the frame. Slide the boiler forward. The burner
box, anchored only by the boiler, must be
prevented from sliding forward with the boiler.
8.
Reverse procedure to install a new boiler and
check for leaks and proper operation.

HIGH LIMIT THERMOSTAT

WARNING: DISCONNECT THE ELECTRICAL
POWER TO THE MACHINE AT THE MAIN
CIRCUIT BOX. PLACE A TAG ON THE CIRCUIT
BOX INDICATING THE CIRCUIT IS BEING
SERVICED.
1.
Open the cabinet base doors.
2.
Electric models only - for gas models proceed
to step 3.
A.
Newer Models - are not equipped with a hi
limit thermostat but rely on the Hi limit
pressure switch instead.
B.
Older Models - the high limit thermostat is
located behind the contactor box cover.
On electric boilers with two heating
elements, the thermostat is connected to
one of the heating element lugs. On
electric boilers with four heating elements,
the thermostat is located on an aluminum
plate between the center pair of elements
at the top of the elements. Remove the
thermostat lead wires and mounting nuts,
replace thermostat and check for proper
operation.
3.
Gas Models only.
A.
Remove the thermostat cover which is
located on the front of the boiler.
Disconnect the thermostat lead wires and
remove the nuts securing the high limit
thermostat to the boiler surface.
4.
Reverse procedure to install and check for
proper operation.