Technical data

Measurement range:
Measuring accuracy (typical):
Smallest display unit:
Operating temperature:
Relative humidity max.:
Laser category:
Wavelength (λ):
Maximum power P max:
Batteries:
Weight:
Dimensions:
A) The range improves the better the laser light is returned from the
surface of the target (dispersing, not refl ecting) and the brighter the
laser is compared to the ambient light (interior rooms, twilight).
48
0.05–50 m
A)
± 2.0 mm
B)
1 mm
0°–40°C
≤ 75%
2
650 nm
< 1 mW
2 x 1.5 V LR03 (AAA)
88 g
11.3 x 4.9 x 2.6 cm