METREL A 1832 Instruction Manual
METREL A 1832 Instruction Manual

METREL A 1832 Instruction Manual

Mode 3 charging cable adapter

Advertisement

Quick Links

METREL test and measurement accessories:
Mode 3 Charging Cable Adapter
A 1832
Instruction manual
Version 1.1.1, Code no. 20 753 362

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the A 1832 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for METREL A 1832

  • Page 1 METREL test and measurement accessories: Mode 3 Charging Cable Adapter A 1832 Instruction manual Version 1.1.1, Code no. 20 753 362...
  • Page 2 Mark on your equipment certifies that it meets requirements of all subjected EU regulations. Hereby, Metrel d.o.o. declares that the A 1832 is in compliance with subjected EU directive. The full text of the EU declaration of conformity is available at the https://www.metrel.si/DoC.
  • Page 3: Table Of Contents

    Safety and operational considerations ..............5 Warnings and notes ..................5 Markings on the adapter ..................5 Standards applied ..................... 6 A 1832 standard set and accessories ..............7 Adapter description ....................8 A 1832 operation ..................... 9 Maintenance ......................9 Cleaning ......................
  • Page 4: Preface

    A 1832 Mode 3 Charging Cable Adapter Preface 1 Preface The A 1832 is intended for testing Mode 3 EV charging cables with type 2 connector. Different tests can be carried out in combination with Metrel safety testers.
  • Page 5: Safety And Operational Considerations

    ❑ for safe operation«. The symbol requires an action! If the A 1832 is used in a manner not specified in this Instruction manual or the ❑ Instruction manual of target test equipment, the protection provided by the A 1832...
  • Page 6: Standards Applied

    A 1832 Mode 3 Charging Cable Adapter Safety and operational considerations 2.3 Standards applied The A 1832 adapter is manufactured and tested in accordance with the following regulations: Safety (LVD) Safety requirements for electrical equipment for measurement, control EN 61010 - 1 and laboratory use –...
  • Page 7: 1832 Standard Set And Accessories

    A 1832 Mode 3 Charging Cable Adapter A 1832 standard set and accessories 3 A 1832 standard set and accessories Mode 3 Charging Cable Adapter (A 1832) ❑ Test instrument connection cable, 3 x 0.75 mm , 1.5 m ❑...
  • Page 8: Adapter Description

    A 1832 Mode 3 Charging Cable Adapter Adapter description 4 Adapter description Figure 4.1: A 1832 front panel Legend: Test input for connection of test instrument to the charging cable’s input side LEDs for indication of continuity of phase and neutral conductors (L1, L2, L3, N)
  • Page 9: 1832 Operation

    6.1 Cleaning No special maintenance is required for the housing. To clean the surface of the adapter, use a soft cloth slightly moistened with soapy water or alcohol. Then leave the A 1832 to dry totally before use. Warnings: Do not use liquids based on petrol or hydrocarbons! ❑...
  • Page 10: Technical Specifications

    A 1832 Mode 3 Charging Cable Adapter Technical specifications 7 Technical specifications 7.1 General data Charging cable connectors………………Type 2 Maximum test current ......10 A on test connector / 25 A on banana sockets Measuring category ....... 50 V no CAT, max. transient overvoltage 1100 V Protection classification ......