Page 1
METREL test and measurement accessories: Mode 3 Charging Cable Adapter A 1832 Instruction manual Version 1.1.1, Code no. 20 753 362...
Page 2
Mark on your equipment certifies that it meets requirements of all subjected EU regulations. Hereby, Metrel d.o.o. declares that the A 1832 is in compliance with subjected EU directive. The full text of the EU declaration of conformity is available at the https://www.metrel.si/DoC.
Safety and operational considerations ..............5 Warnings and notes ..................5 Markings on the adapter ..................5 Standards applied ..................... 6 A 1832 standard set and accessories ..............7 Adapter description ....................8 A 1832 operation ..................... 9 Maintenance ......................9 Cleaning ......................
A 1832 Mode 3 Charging Cable Adapter Preface 1 Preface The A 1832 is intended for testing Mode 3 EV charging cables with type 2 connector. Different tests can be carried out in combination with Metrel safety testers.
❑ for safe operation«. The symbol requires an action! If the A 1832 is used in a manner not specified in this Instruction manual or the ❑ Instruction manual of target test equipment, the protection provided by the A 1832...
A 1832 Mode 3 Charging Cable Adapter Safety and operational considerations 2.3 Standards applied The A 1832 adapter is manufactured and tested in accordance with the following regulations: Safety (LVD) Safety requirements for electrical equipment for measurement, control EN 61010 - 1 and laboratory use –...
A 1832 Mode 3 Charging Cable Adapter A 1832 standard set and accessories 3 A 1832 standard set and accessories Mode 3 Charging Cable Adapter (A 1832) ❑ Test instrument connection cable, 3 x 0.75 mm , 1.5 m ❑...
A 1832 Mode 3 Charging Cable Adapter Adapter description 4 Adapter description Figure 4.1: A 1832 front panel Legend: Test input for connection of test instrument to the charging cable’s input side LEDs for indication of continuity of phase and neutral conductors (L1, L2, L3, N)
6.1 Cleaning No special maintenance is required for the housing. To clean the surface of the adapter, use a soft cloth slightly moistened with soapy water or alcohol. Then leave the A 1832 to dry totally before use. Warnings: Do not use liquids based on petrol or hydrocarbons! ❑...
A 1832 Mode 3 Charging Cable Adapter Technical specifications 7 Technical specifications 7.1 General data Charging cable connectors………………Type 2 Maximum test current ......10 A on test connector / 25 A on banana sockets Measuring category ....... 50 V no CAT, max. transient overvoltage 1100 V Protection classification ......
Need help?
Do you have a question about the A 1832 and is the answer not in the manual?
Questions and answers