Blower Adjustment - Vulcan-Hart VC4EC Service Manual

Vc4e & vc6e series full size electric convection ovens
Hide thumbs Also See for VC4EC:
Table of Contents

Advertisement

FULL SIZE ELECTRIC CONVECTION OVENS - SERVICE PROCEDURES AND ADJUSTMENTS

BLOWER ADJUSTMENT

1.
Remove the blower motor and mounting assembly by following steps 1 through 7 as outlined under BLOWER
AND MOTOR in REMOVAL AND REPLACEMENT OF PARTS.
2.
Loosen the motor mounting bolts.
3.
Adjust the motor position until the blower is parallel to and 1/4 inch away from the motor mounting plate.
Check for squareness of the blower to the motor mounting plate at the top, bottom, left and right of the
blower.
A.
If the blower is square then tighten motor mounting bolts and proceed to step 4.
B.
If the blower is not square continue adjusting until proper spacing is achieved then tighten motor
mounting bolts.
NOTE: If necessary, place shims between motor and frame.
4.
Reverse the procedure to install.