Vulcan-Hart ECO2C Service Manual page 21

Half-size convection ovens electric and gas
Table of Contents

Advertisement

HALF-SIZE CONVECTION OVENS - ELECTRICAL OPERATION
6.
Temperature is satisfied and control contacts 6/7
open
A.
Heat light goes out.
B.
Power removed from ignition transformer.
7.
Ignition module de-energized
A.
Gas valve de-energized, gas supply to burner
off.
8.
Oven cycles on solid state control until power switch
is moved from the "on" position or the door is
opened.
NOTE: The blower motor, heat lamp and gas valve
are de-energized when the door is opened during
the heat mode.
Solid State Timer (Gas)
NOTE: Use GCO2D Schematic
NOTE: The timer is not connected to the heating circuit
and will not prevent the oven from heating when time
expires.
1.
Power switch on
2.
Time dialed into timer, contacts 1/3 close.
A.
Timer motor energized: wire #34/64; timer
contacts 1/3; wht wire; wire #37
3.
Time expires.
A.
Contacts 1/3 open
1)
Timer motor de-energized
B.
Contacts 1/4 close
4.
Buzzer sounds: wire #34/64; timer contacts 1/4; wire
#66; wire #65/37
5.
Timer turned to off.
A.
Contacts 1/4 open
1)
buzzer de-energized
Cooldown (Gas/Solid State Control)
NOTE: Use GCO2D Schematic
1.
Conditions
A.
Oven temperature needs to be lowered.
B.
Power switch on
2.
Cooldown switch on
A.
Blower motor energized: power switch; wire
#34/33/36/11; J1-11; wire #11; wire #13/7; J1-
7; wire #7/37; power switch
Electronic Control (Gas)
NOTE: Use GCO2C Schematic
NOTE: A combination of terminal numbers and wire
numbers will be used to describe the circuit paths. The
complete path will be described when a component is
energized.
Heat
1.
Conditions.
A.
Supply voltage to unit.
1)
L1 to power/cooldown switch: wire #1;
J1-1; wire #1
2)
L2 to:
a.
b.
c.
3)
Good chassis ground: ignition module
transformer
a.
b.
c.
d.
B.
Power/cooldown "off".
C.
Oven at room temperature.
D.
Door switch closed.
E.
Manual gas valve open.
2.
Power/cooldown switch turned "on"
A.
Control transformer primary powered: wire
#26/4; J1-4; wire #4/94; wire #97/7; J1-7; wire
#2; J1-2; wire #2; L2
3.
Control powered from secondary of control
transformer:
A.
6 VAC - wire #16; J1-16; J2-3; J2-2; J1-15;
wire #15
B.
12 VAC - wire #14; J1-14; J2-1; J2-2; J1-15;
wire #15
4.
Control set to desired temperature
A.
Control verifies heat mode: 16 to 18 VDC
output on J2-11; J1-20; wire #20/21;
power/cooldown switch; contacts of switch are
open and no return voltage to J2-5
B.
Control verifies that door is closed: 16 to 18
VDC output on J2-11; J1-20; wire #20/27; door
switch; wire #3; J1-3; J2-4
21
Motor: wire #2; J1-2; wire #2; J1-7;
wire #7/13
Primary of ignition transformer: wire
#2; J1-2; wire #2; J1-7; wire #7
Primary of control transformer: wire
#2; J1-2; wire #2; J1-7; wire #7/97
Ignition module: GND
Electronic control: terminal 8 of
control; J2-8; J1-6; wire #6; GND
Gas valve: wire #48; GND
Ignition transformer: GND

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gco2cEco2dGco2d

Table of Contents