Download Print this page

Advertisement

Quick Links

www.insigniarange.com
Last Modified: 07/10/2015
www.insigniarange.co.uk
INSTALLATION MANUAL
30 Day Technical Support:
01908 226545
GT8720
(NOTE: This service is only available to customers from the day of delivery,
please have your supplier's details and your postcode to hand before calling)
Replacements Parts:
inside of your warranty contact:
www.insigniarange.co.uk/customerService.aspx
Spares/Replacements Parts:
outside of your warranty
contact 0844 800 3069
ATTENTION INSTALLERS:
These instructions must be
WARRANTY REG NO: __________________________
left with the customer
To claim your full 5 year warranty, register your shower within 90 days of delivery at: www.insigniarange.co.uk/
warrantyreg.aspx. Standard 12 month warranty applies if outside this time period.

Advertisement

loading

Summary of Contents for Insignia GT8720

  • Page 1 INSTALLATION MANUAL 30 Day Technical Support: 01908 226545 GT8720 (NOTE: This service is only available to customers from the day of delivery, please have your supplier’s details and your postcode to hand before calling) Replacements Parts: inside of your warranty contact: www.insigniarange.co.uk/customerService.aspx...
  • Page 2 www.insigniarange.com Last Modified: 07/10/2015 Contents Introduction Electrical Requirements What’s In The Boxes? Screw Pack Contents Plumbing Requirements Starting The Installation Electric Box Connections Sealing and Water Testing MK117 Control Panel Instructions Help Book Information Parts List...
  • Page 3 Last Modified: 07/10/2015 Thank you for your recent purchase of an Insignia shower. Please read this booklet with great care to ensure you get the best out of your build and have a shower that will last for many years to come! Like everything, in order to obtain a first class product that will serve you well for many years, the effort and correctness put into the assembly will reflect in the quality of your finish.
  • Page 4 www.insigniarange.com Last Modified: 07/10/2015 ASSEMBLY AND SIMPLE PLUMBING THIS PRODUCT BUILD IS RATED SUITABLE FOR DIY PURPOSES PROVIDING THE CUSTOMER IS OF ABOVE AVERAGE SKILLS AND FEELS CONFIDENT IN THEIR ABILITY. ONLY YOU THE CUSTOMER WILL KNOW THIS SO BEFORE ANY ATTEMPT IS MADE TO ASSEMBLY READ THROUGH THE FOLLOWING PAGES IN DETAIL THEN DECIDE.
  • Page 5 www.insigniarange.com Last Modified: 07/10/2015 YOU WILL NEED TOTAL ELECTRICAL REQUIREMENTS Voltage Rating 220 -240AC Frequency Rating 50HZ Power Rating 12V AC-DC Internal Circuit Voltage is Internal Current Rating 0.17A Your electrical contractor should understand ALL legal requirements of connection before undertaking any work or installation. UNDER NO CIRCUMSTANCES UNDERTAKE THIS YOURSELF!!! Note for electrician.
  • Page 6 www.insigniarange.com Last Modified: 07/10/2015 Whilst the next steps show you how to assemble your shower we want to make sure you have a correct build to ensure you get a trouble free shower. Therefore our advice is to follow the instructions and perform a dry run to ensure you are confident with the build and you understand fully how the unit is assembled. When we use the word “DRY RUN”...
  • Page 7 Note: In some cases you may have more screws than needed, this is done so you have spares! VERY IMPORTANT Have you got everything? If not please contact the Insignia Support Line on 01908 226545. Remember NEVER book your tradesman until everything has arrived, been checked and is present.
  • Page 8 www.insigniarange.com Last Modified: 07/10/2015 Pressure Requirements from your house supply We recommend a bar pressure between 2.5 and 3.4 BAR. If you have a combi boiler system no problem should be experienced. If you have a gravity feed older type installation (hot water tank type usually less than 1 bar) you will almost certainly need a pump.
  • Page 9 Once you are happy with the levelling of the tray, you can pull it out to begin the main construction. Step 1 Attach the uprights to the bottom curved rail using the ST35 screws (Thinner rail without Insignia logo on)
  • Page 10 www.insigniarange.com Last Modified: 07/10/2015 Step 2 Push the “U Shape” glass seal onto the glass panel prior to insertion into the frames. Please ensure the thin seal is on the entrance side of the panels with the thicker to the rear side. The next step is to attach both front fixed glass panels.
  • Page 11 www.insigniarange.com Last Modified: 07/10/2015 Step 4 Apply silicone to the bottom of the remaining back panel and position the panel to the completed front frame in the position shown in the image marked “1” Once you have met the back panel inside the front upright as per the close up image walk the panel around to the position shown in the image marked “2”...
  • Page 12 www.insigniarange.com Last Modified: 07/10/2015 Step 6 Align the roof with your shower walls and using the ST25 screws fix the back walls to the roof by screwing upwards from the rear of the shower. NOTE: If a small gap exists silicone seal later Step 7 Fit the adjustable wheels to the top and bottom of the glass doors and ensure the wheels are at their lowest position and hang on the inner curved rails with the wheels facing the...
  • Page 13 www.insigniarange.com Last Modified: 07/10/2015 Accessory Installation Please Note Ensure all grey backing film on the rear of the glass panels are pierced through the existing glass holes with a knife to provide an efficient smooth fitting and location of the accessories. We recommend using a screwdriver on the smaller holes.
  • Page 14 www.insigniarange.com Last Modified: 07/10/2015 Hand Shower Attach the chrome riser bar to the glass wall ensuring the water inlet is inserted through the lower large hole and hand tightened from the rear side. Now tighten the chrome shower holder ensuring that this will take the hand shower itself without falling (please note over tightening will prevent the holder from sliding up and down) Thermostatic Probe...
  • Page 15 Connect the corresponding hoses to the rear of the valve as shown. Device output may differ from the image. Please refer to your outer chrome faceplate in- side your Insignia shower as a reference point. IF YOUR DIAL DOES NOT CORROSPOND TO THE APPROPRIATE DEVICE: Turn on your water to the shower and note which output the water exits from then turn off the water and swap over the relevant hose.
  • Page 16 www.insigniarange.com Last Modified: 07/10/2015 Electric Box Connections Connect the cables below to the corresponding devices on the shower Speaker Roof Light Back Lights RJ11 Phone Connection Antenna 12V power Supply...
  • Page 17 www.insigniarange.com Last Modified: 07/10/2015 Connection For Tray & Column Lights Using the supplied extension lead, please connect the end with the single connection to your tray lights. Next bring the extension lead up the back of the shower and connect one of the plugs to the column lights (essentially bridging the two sets of lights together) Now with the remaining connection, connect this into the wire coming from the electric box with the column light sticker on (as shown in the image)
  • Page 18 www.insigniarange.com Last Modified: 07/10/2015 Silicone Seal where shown in red on the inside of the shower TESTING FOR WATER LEAKS LEAVING SHOWER 24 HOURS AFTER BUILD ALLOWING SEALENT TO CURE With all connections tight, the waste and hoses checked, jets fully sealed, your shower still around 18 inches from its designated final resting point and the silicone fully cured (hence leaving for 24 hours minimum) Switch on the overhead shower NOT the massage jets, remember these will fire water out at you and are not suitable for checking leaks as they would normally only operate when a person is in front of them.
  • Page 19 www.insigniarange.com Last Modified: 07/10/2015 MK117L Control Panel Instructions Button 1 (Light Bulb) Button 7 (Down Arrow) Press 1x For Top Light Channel select down/manual search down Press 2x For Column Light Button 8 (M) Press 3x For All Lights Access saved channels Press 4x To Switch Off Lights Button 9 (Up Arrow) Button 2 (Radio)
  • Page 20 Last Modified: 07/10/2015 Need Help? If so then simply download Insignia’s free comprehensive help and troubleshooting brochure now! Simply visit: www.insigniarange.co.uk/help.aspx...
  • Page 21 Internal Items Framework SP038 Speaker Part Code Part Description Part Code Part Description SP063 Monsoon Shower head SP007 GT8720-7 Bottom Rail SP040 Massage jet—2 open ends SP037 Fan & speaker cover GT8720-8 Top rail SP040A Massage jet—1 open, 1 closed GT8720-4...
  • Page 22 All images are registered with ImageTraker Insignia™ is a registered trademark of Maclean International Ltd All images are subject to copyright. Images may not be used in any way shape or form with out written permission from Maclean International Ltd. Images are NOT permitted...