INSTALLATION MANUAL
GT9002R
ATTENTION INSTALLERS:
These instructions must be
left with the customer
www.insigniarange.com
CHECK ALL CONTENTS BEFORE BUILD COMMENCES. NO RETURNS CAN BE MADE
ONCE THE BUILD HAS STARTED AS IT IS DEEMED ACCEPTANCE OF PRODUCT!
WARRANTY REG NO: __________________________
To claim your full 5 year warranty, register your shower within 90 days of delivery at: www.insigniarange.co.uk/
warrantyreg.aspx. Standard 12 month warranty applies if outside this time period.
Last Modified: 06/11/2017
www.insigniarange.co.uk
30 Day Technical Support:
(NOTE: This service is only available to customers from the day of delivery,
please have your supplier's details and your postcode to hand before calling)
Replacements Parts:
inside of your warranty contact:
www.insigniarange.co.uk/customerService.aspx
Spares/Replacements Parts:
outside of your warranty
contact 0844 800 3069
01908 226545

Advertisement

loading

Summary of Contents for Insignia GT9002R

  • Page 1 INSTALLATION MANUAL 30 Day Technical Support: 01908 226545 GT9002R (NOTE: This service is only available to customers from the day of delivery, please have your supplier’s details and your postcode to hand before calling) Replacements Parts: inside of your warranty contact: www.insigniarange.co.uk/customerService.aspx...
  • Page 2 www.insigniarange.com Last Modified: 06/11/2017 Contents Introduction Electrical Requirements What’s In The Boxes? Screw Pack Contents Plumbing Requirements Schematics Starting The Installation Electric Box Connections Sealing and Water Testing MK117L Control Panel Instructions Help Book Information Parts list...
  • Page 3 Last Modified: 06/11/2017 Thank you for your recent purchase of an Insignia shower. Please read this booklet with great care to ensure you get the best out of your build and have a shower that will last for many years to come! Like everything, in order to obtain a first class product that will serve you well for many years, the effort and correctness put into the assembly will reflect in the quality of your finish.
  • Page 4 DURING BUILD, LIKE ALL SHOWERS CORRECT SEALING IS IMPERATIVE. If you are using Insignia’s RubberGum, please ensure the product does not come in contact with your silicone as this will cause the RubberGum to fail and will not adhere as intended.
  • Page 5 www.insigniarange.com Last Modified: 06/11/2017 TOTAL ELECTRICAL REQUIREMENTS Voltage Rating 220 -240AC Frequency Rating 50HZ Power Rating Your electrical contractor should understand ALL legal requirements of connection before undertaking any work or installation. UNDER NO CIRCUMSTANCES UNDERTAKE THIS YOURSELF!!! Note for electrician. This product comes with 3 amp plug. We leave it this way for you to connect this your own way due to continued additions to current regulations.
  • Page 6 www.insigniarange.com Last Modified: 06/11/2017 Tool Requirements None Supplied Scissors Stanley Blade Silicone Gun Spirit Level Tape Measure Philips Screwdriver Electric Drill Adhesive Requirements Bacteria Resistant Sanitary Silicone - (for vertical joints) RubberGum Plumbers Mait (for waste joints) Not Supplied Supplied Not Supplied Hardware Requirements A Hydro-Massage Shower requires 2 x 1 Metre Braided Hose...
  • Page 7 www.insigniarange.com Last Modified: 06/11/2017 Whilst the next steps show you how to assemble your shower we want to make sure you have a correct build to ensure you get a trouble free shower. Therefore our advice is to follow the instructions and perform a dry run to ensure you are confident with the build and you understand fully how the unit is assembled. When we use the word “DRY RUN”...
  • Page 8 Note: In some cases you may have more screws than needed, this is done so you have spares! VERY IMPORTANT Have you got everything? If not please contact the Insignia Support Line on 01908 226545. Remember NEVER book your tradesman until everything has arrived, been checked and is present.
  • Page 9 www.insigniarange.com Last Modified: 06/11/2017 Pressure Requirements from your house supply We recommend a bar pressure between 2.5 and 3.4 BAR. If you have a combi boiler system no problem should be experienced. If you have a gravity feed older type installation (hot water tank type usually less than 1 bar) you will almost certainly need a pump.
  • Page 10 www.insigniarange.com Last Modified: 06/11/2017...
  • Page 11 www.insigniarange.com Last Modified: 06/11/2017 Whilst the next steps show you how to assemble your shower we want to make sure you have a correct build to ensure you get a trouble free shower. Therefore our advice is to follow the instructions and perform a dry run to ensure you are confident with the build and you understand fully how the unit is assembled.
  • Page 12 www.insigniarange.com Last Modified: 06/11/2017 Step 2 Now attach the large back panel to the column. Once you are happy with the alignment, run a bead of silicone up the edge and Rubbergum along the bottom of the panels and screw together using the ST20 Step 3 Front Fixed Uprights.
  • Page 13 www.insigniarange.com Last Modified: 06/11/2017 Step 3 (Continued) Please Note: With the groove sitting on the tray, you need to have the “U” shaped channel facing inwards to allow the glass to be inserted correctly. Step 3 The next step is to attach both front uprights to the curved rails using the ST35 screws as shown in the picture to the left PLEASE NOTE The screw head needs to bypass the OUTER hole.
  • Page 14 www.insigniarange.com Last Modified: 06/11/2017 Step 4 Now attach your front metal work to the fitted back panels. Once you are happy with the alignment, run a bead of silicone up the edge and Rubbergum along the bottom of the panels and frame and screw together using the ST20 Step 5 Next attach the “U shape”...
  • Page 15 www.insigniarange.com Last Modified: 06/11/2017 Step 6 With the frame now attached to the back panels, locate and fix the glass panels into place by pushing them as per the arrows in the adjacent image Making sure the edge of the glass with the rubber seal fits into the grove tightly. Now screw the glass retaining clips into place using the ST14 screws making sure the glass has a tight fit Step 7 Using the ST25 screws, ensure the back panels are square and you are happy with the...
  • Page 16 www.insigniarange.com Last Modified: 06/11/2017 Step 8 Next locate the roof into position. Once you are happy with the positioning of this, screw into place using the ST25 screws, Step 9 Fit the adjustable wheels to the top and bottom of the glass doors and ensure the wheels are at their lowest position and hang on the inner curved rails with the wheels facing the outside of the glass.
  • Page 17 www.insigniarange.com Last Modified: 06/11/2017 Accessory Installation Please Note Ensure all grey backing film on the rear of the glass panels are pierced through the existing glass holes with a knife to provide an efficient smooth fitting and location of the accessories. We recommend using a screwdriver on the smaller holes.
  • Page 18 www.insigniarange.com Last Modified: 06/11/2017 Door Seals Magnetic Seal: Push the magnetic door seal on the handle side of the glass door ensuring this is tightly fitted. Rear Door Seal: Place the rear door seal on the opposite side to the magnetic strip ensuring the flap is facing the fixed glass panel Handle Ensuring that the inner thread is protruding out from the handle far enough, place the handle...
  • Page 19 Connect the corresponding hoses to the rear of the valve as shown. Device output may differ from the image. Please refer to your outer chrome faceplate in- side your Insignia shower as a reference point. IF YOUR DIAL DOES NOT CORRESPOND TO THE APPROPRIATE DEVICE: Turn on your water to the shower and note which output the water exits from then turn off the water and swap over the relevant hose.
  • Page 20 www.insigniarange.com Last Modified: 06/11/2017 Electric Box Connections Connect the cables below to the corresponding devices on the shower Speaker Roof Light Back Lights RJ11 Phone Connection Antenna 12V power Supply...
  • Page 21 www.insigniarange.com Last Modified: 06/11/2017 Silicone Seal (vertical joints) RubberGum (horizontal joints) TESTING FOR WATER LEAKS LEAVE THE SHOWER 24 HOURS AFTER BUILD TO ALLOW SEALENT TO CURE AND ENSURE THE SHOWER IS AWAY FROM ITS FINAL POSITION TO ALLOW REAR VIEWING Ensure all connections are tight and sealed including the waste, body jets and steam outlet (model dependent) on your shower.
  • Page 22 www.insigniarange.com Last Modified: 06/11/2017 MK117L Control Panel Instructions Button 1 (Light Bulb) Button 7 (Down Arrow) Press 1x For Top Light Channel select down/manual search down Press 2x For Column Light Button 8 (M) Press 3x For All Lights Access saved channels Press 4x To Switch Off Lights Button 9 (Up Arrow) Button 2 (Radio)
  • Page 23 www.insigniarange.com Last Modified: 06/11/2017 Need Help? Then simply download the following "Help" advice booklet found at this link below. This contains many useful items such as is your parts warranty registered, advice on cleaning / servicing your shower cabin, fault finding and many more items. This is a MUST to read and not just "HELP". It saves time in nearly all cases, avoiding contact with ourselves as most answers are there for a ready fix! Simply visit: www.insigniarange.co.uk/help.aspx...
  • Page 24 Last Modified: 06/11/2017 Parts List Internal Items Framework (Right hand) Part Code Part Description SP038 Speaker Part Code Part Description GT9002R-10 Left Upright (Angled) SP007 Fan (Pre-2017) SP063 Monsoon Shower head SP037 Fan & speaker cover SP243 Fold down seat...
  • Page 25 All images are registered with ImageTraker Insignia™ is a registered trademark of Maclean International Ltd All images are subject to copyright. Images may not be used in any way shape or form with out written permission from Maclean International Ltd. Images are NOT permitted...