Table 3-2 Section Names And Defined Messages - Hitachi HF-W7500 65 Feature Manual

Industrial computer
Hide thumbs Also See for HF-W7500 65:
Table of Contents

Advertisement

■ Description in a Message
1. Section
The table below shows a list of section names you can define for this function and an
explanation of the message you define for each section.
Section name
[PS-FAN]
[FT-FAN1]
[FT-FAN2]
[TEMP]
[DRV1-SMART]
(*1)
[DRV2-SMART]
(*1)
[DRV3-SMART]
(*1)
[DRV1-OFFLINE]
[DRV2-OFFLINE]
[DRV1-OVERRUN]
(*1)
[DRV2-OVERRUN]
(*1)
[DRV3-OVERRUN]
(*1)
[DIMM1-ERR]
[DIMM2-ERR]
[DIMM3-ERR]
[DIMM4-ERR]
[DIMM1- FAILURE] A message displayed when an Memory failure prediction is detected in
[DIMM2- FAILURE] A message displayed when an Memory failure prediction is detected in
[DIMM3- FAILURE] A message displayed when an Memory failure prediction is detected in
[DIMM4- FAILURE] A message displayed when an Memory failure prediction is detected in
(*1) Regardless of the mounted drive, this section name is fixed.
Definition File

Table 3-2 Section Names and Defined Messages

A message displayed when a PS fan failure is detected.
A message displayed when a Front fan1 failure is detected.
A message displayed when a Front fan2 failure is detected.
A message displayed when an abnormal temperature inside the chassis is
detected.
A message displayed when a drive failure prediction (SMART) is detected
for the drive bay1.
A message displayed when a drive failure prediction (SMART) is detected
for the drive bay2.
A message displayed when a drive failure prediction (SMART) is detected
for the drive bay3.
A message displayed when a RAID failure is detected due to a drive failure
at drive bay1.
A message displayed when a RAID failure is detected due to a drive failure
at drive bay2.
A message displayed when the drive power-on (=used) hours exceeds the
determined value for the drive bay1.
A message displayed when the drive power-on (=used) hours exceeds the
determined value for the drive bay2.
A message displayed when the drive power-on (=used) hours exceeds the
determined value for the drive bay3.
A message displayed when an error correction is detected frequently in
DIMM A1.
A message displayed when an error correction is detected frequently in
DIMM A2.
A message displayed when an error correction is detected frequently in
DIMM B1.
A message displayed when an error correction is detected frequently in
DIMM B2.
DIMM A1
DIMM A2
DIMM B1
DIMM B2
3. SETTING UP THE RAS FEATURE
Defined message
3-15

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hf-w7500 60