Larson Electronics EPL-HB-100LED-RT-UVA-20C-EPP Instruction Manual

Larson electronics epl-hb-100led-rt-uva-20c-epp

Advertisement

Quick Links

Class 1 Division 1 Explosion Proof 100 Watt
Ultraviolet LED Light Fixture - 365NM – Exp Plug
EPA Reg. No 98409-1
EPA Est. No. 98409-TX-1
The Larson Electronics Explosion Proof Ultraviolet light fixture provides operators with a powerful and energy efficient alternative to
traditional hazardous location luminaires. This fixture uses advanced LED light technology to produce ultraviolet light and is
T6 rated for hazardous locations where UV lamps are used in paint and adhesive curing, food inspection or for non-destructive
testing.
Lamp operates from 100-277 Volts AC, 50/60Hz. Check product for correct voltage before energizing!
100-277V AC Model
An internal, universal input, power-factor-corrected switch-mode supply allows it to be used from any nominal
100-277V AC 50/60 Hz power supply without any variation in light output.

WARNING

To avoid the risk of fire, explosion or electric shock, this product should be installed, inspected and maintained by a qualified electrician
only, in accordance with all applicable electrical codes.
Ultraviolet light can cause damage to the human eye. Do not stare directly into the ultraviolet beam
without wearing protective gear to protect eyes from long term damage.
To avoid electric shock:
Be certain electrical power is OFF before and during installation and maintenance.
Luminaire must be connected to a wiring system with an equipment-grounding conductor.
To avoid explosion:
Make sure the supply voltage is within the luminaires' voltage rating.
Ensure the marked T rating is less than the ignition temperature of the Hazardous Atmosphere.
Do not operate in ambient temperatures above those indicated on the luminaire nameplate.
Do not operate if the lens is cracked or damaged. All fasteners should be properly seated.
For supply connections, use wire rated for at least 110°C
Recommended mounting height is 25-40 feet.

MOUNTING

This fixture offers an adjustable mounting system that allows this fixture to be mounted to any flat surface including walls and
ceilings. A single ½-13 bolt is used to mount the fixture to the surface.
Check to ensure that all mounting hardware is included.
2 Small Brackets
1 Large Trunnion Bracket
8 Bolts
8 Lock-Washers
4 Nuts
See reference images on next page.
1. Using four bolts, washers and the four nuts provided, attach brackets "A" to both sides of bracket "B".
2. The LED fixture has 9 holes for a versatile mount option. Select the holes that you would like to use.
Larson Electronics, LLC
Instruction Manual
Phone: (800) 369-6671
EPL-HB-100LED-RT-UVA-20C-EPP
Fax: (903) 498-3364
www.larsonelectronics.com
1 of 2

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EPL-HB-100LED-RT-UVA-20C-EPP and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Larson Electronics EPL-HB-100LED-RT-UVA-20C-EPP

  • Page 1 EPA Reg. No 98409-1 EPA Est. No. 98409-TX-1 The Larson Electronics Explosion Proof Ultraviolet light fixture provides operators with a powerful and energy efficient alternative to traditional hazardous location luminaires. This fixture uses advanced LED light technology to produce ultraviolet light and is T6 rated for hazardous locations where UV lamps are used in paint and adhesive curing, food inspection or for non-destructive testing.
  • Page 2 Do not operate if the lens is cracked or damaged. All fasteners should be properly seated. THESE INSTRUCTIONS MAY NOT COVER ALL DETAILS OR VARIATIONS OF THIS PRODUCT FOR YOUR EQUIPMENT OR INSTALLATION REQUIREMENTS. SHOULD FURTHER INFORMATION NOT COVERED BY THESE INSTRUCTIONS BE REQUIRED, PLEASE CONTACT LARSON ELECTRONICS BY EMAIL AT SALES@LARSONELECTRONICS.COM OR BY PHONE AT 1-800-369-6671 FOR FURTHER ASSISTANCE.
  • Page 3 THESE INSTRUCTIONS MAY NOT COVER ALL DETAILS OR VARIATIONS OF THIS PRODUCT FOR YOUR EQUIPMENT OR INSTALLATION REQUIREMENTS. SHOULD FURTHER INFORMATION NOT COVERED BY THESE INSTRUCTIONS BE REQUIRED, PLEASE CONTACT LARSON ELECTRONICS BY EMAIL AT SALES@LARSONELECTRONICS.COM OR BY PHONE AT 1-800-369-6671 FOR FURTHER ASSISTANCE.

Table of Contents