C.fn: Setting Custom Functions; Protection Function - Godox V1 N PRO Manual

Ttl li-ion round head camera flash
Hide thumbs Also See for V1 N PRO:
Table of Contents

Advertisement

C.Fn: Setting Custom Functions

Press the menu button to enter C.Fn settings.
Custom Function Signs
Function
m/ft
Distance indicator
AF
AF-assist beam
STBY
Auto sleep setting
RX STBY
Receiver auto
power off timer
SCAN
Scan the spare
channel
CH
Wireless Channel
ID
ID
BEEP
Beeper
LIGHT
Backlighting time
LCD
LCD contrast ratio
Note:
1. The "Verx.x" in the top-right corner refers to the software version.
2. Turn the select dial to select the custom function No. and its parameters.
3. Press set button to select the custom function No. and confirm its setting.
4. After you set the custom function and press <MENU> menu button, the camera
will be ready to shoot.
5. Press and hold the function button 1 <CLEAR> in the MENU interface until "OK" is
displayed on the panel, which means the parameters in C.Fn are reset.

Protection Function

Over-Temperature Protection
To avoid overheating and deteriorating the flash head, do not fire more
than 100 continuous flashes in fast succession at 1/1 full power. After 100
continuous flashes, allow a rest time of at least 10 minutes.
If you fire more than 100 continuous flashes and then fire more flashes
in short intervals, the inner over-temperature protection function may be
activated and make the recycle time over 10 seconds. If this occurs, allow a
rest time of about 10 minutes, and the flash unit will then return to normal.
When the over-temperature protection is started, <> is shown on the LCD
display.
Options
Settings & Description
m
m
ft
Feet
ON
ON
OFF
OFF
ON
ON
OFF
OFF
60min
Power off automatically
after 60 minutes of idle
use when the flash is set
30min
as a receiver unit.
Power off automatically
after 30 minutes of idle
use when the flash is set
as a receiver unit.
OFF
OFF
START
Start to scan the spare
channel
01-32
Choose channels from
01-32
OFF
OFF
01-99
Choose any figure from
01-99
ON
ON
OFF
OFF
12sec
Off in 12 sec.
OFF
Always off
ON
Always lighting
-3~+3
7 levels
44
Number of flashes that will activate over-temperature protection:
Power Output Level
1/1
1/2 (+0.1~+0.9)
1/4(+0.1~+0.9)
1/8(+0.1~+0.9)
1/16(+0.1~+0.9)
1/32(+0.1~+0.9)
1/64(+0.1~+0.9)
1/128(+0.1~+0.9)
1/256(+0.1~+0.9)
Note: Numbers of flashes of over-temperature protection are different in different zoom values
and different levels.
Number of flashes that will activate over-temperature protection in HSS
mode:
Power Output Level
1/1
1/2 (+0.1~+0.9)
1/4(+0.1~+0.9)
1/8(+0.1~+0.9)
1/16(+0.1~+0.9)
1/32(+0.1~+0.9)
1/64(+0.1~+0.9)
1/128(+0.1~+0.9)
1/256(+0.1~+0.9)
Number of Flashes
100
150
300
300
1100
3500
3500
3500
3500
Number of Flashes
60
70
100
100
100
100
100
100
100
45

Advertisement

Table of Contents
loading

This manual is also suitable for:

10768V1f proV1 o pro

Table of Contents