7.10 Sensor sensitivity
In automatic mode, a sensor in the appliance detects
the intensity of the cooking odours and roasting
odours. Depending on the setting of the sensor sensit-
ivity, the optimum fan setting is automatically switched
on.
If the sensor control reacts too weakly or too strongly,
you can change the setting for the sensor sensitivity.
¡ Default setting: Fan setting 3
¡ Lowest setting: Fan setting 1
¡ Highest setting: Fan setting 5
7.11 Setting the sensor sensitivity
Requirement: The appliance is switched on.
Press and hold
⁠   and
1.
Press
⁠   or 
to change the setting.
2.
Press
to save the setting.
3.
Or wait approx. five seconds until the setting is
saved automatically.
a A signal tone sounds as soon as the selected set-
ting is saved.
7.12 Saturation indicator
If the grease filters or odour filters are saturated, cor-
responding symbols flash after the appliance is
switched off.
Note: You can set the saturation indicator in the Home
Connect app depending on the filter used.
Clean the saturated grease filters and, in doing so, ob-
serve the cleaning instructions in these instructions.
Change the saturated odour filters and observe the in-
structions in the accompanying instructions.
If odour filters can be regenerated, follow the instruc-
tions in the accompanying instructions.
7.13 Setting the saturation indicator
The saturation indicator must be adjusted depending
on the filter used.
Requirement: The appliance is switched on.
Press and hold
⁠   and
1.
To set circulating-air mode (Clean Air Standard
circulating-air set or Clean Air Plus circulating-air
set), press and hold
the LED display.
To set circulating-air mode (regenerable filter),
press
⁠ /
until LED 3 lights up in the LED dis-
play.
To convert the electronic control back to opera-
tion without the air recirculation filter, press
until LED 1 lights up on the LED display.
Press
to save the setting.
2.
Or wait approx. five seconds until the setting is
saved automatically.
a A signal tone sounds as soon as the selected set-
ting is saved.
1
Depending on the appliance specifications
1
1
⁠   for approx. 3 seconds.
⁠   for approx. 3 seconds.
⁠ /
until LED 2 lights up in
7.14 Resetting the saturation indicator
After cleaning the grease filter or after changing the
odour filter, the saturation indicator can be reset.
Requirements
¡ After switching off the appliance, the upper two LEDs
for the grease filter's saturation indicator and/or the
lower two LEDs for the odour filter's saturation indic-
ator flash in the left hand control panel.
¡ A signal sounds repeatedly.
Press
.
a The saturation indicator is reset.
7.15 Switching on Guided Air
With the Guided Air function, the cooking vapour is
routed in such a way that it can be optimally collected
from the appliance and removed. The extraction of the
cooking vapour is improved on front cooking zones in
particular.
Note: This function is switched off by default.
Press  ⁠ .
7.16 Switching off Guided Air
Press  ⁠ .
⁠ /