manufacturer. In this machine, there is a pressure decrease valve to keep theinflation
pressure not exceed 3.5bar.
For tubeless wheel with lax tire, the common inflation is invalid and can use the quick
inflation then common inflation. (The quick inflation function is not standard configuration
and need to special order).
Step down the inflation pedalto the bottom position (second gear) and quickly release the
pedal when the tireis full to the position of the first gear.
Note: the machine equips the reducing valve and set the pressure value at 3.5 bar. Customers
can get different inflation pressure by adjusting the pressure decrease valve according to their
own requirement.If the inflation pressure too high, you can press down the deflation press
button on the inflation device to reach the required air pressure.
Warning! Explosive!
When inflation, you must follow the above safety operation and abide by the following
instruction:
Carefully check is the size of the rim same to the size of the tire and also check the wear
condition of the tire to secure there is no damage before inflation.
When the inflation pressure is relatively high, you should remove the tire from the
machine and inflate in the protective cover.
When inflate the tire, be carefully, keep your hands and body far away from the tire.