6-7-2. Out of Measurement Range
If (4, Quer] blinks on the display:
When [£, Auer] blinks even after setting the flash measurement range to
[i], measurement cannot be taken. In this case, adjust the flash output
power or move away from the light source and take another measure-
ment.
If LL, Hader] blinks on the display:
When [Lf, Under] blinks even after setting the flash measurement range
to IÑ, measurement cannot be taken. In this case, adjust the flash output
power or move closer to the light source and take another measurement.
Display of Over measurement range
Display of under measurement range
made
nam SCULK
RANGEL
Measurement Range(for ISO 100):
Brightness in measurement of color temperature:
Ambient light:
EV3 (20Ix) to EV16.3 (200,000Ix)
Flash light L range:
£2.80 to f22s
Flash light H range:
160 to f90s
Simplified illuminance: Ix:2.5 to 610,000Ix
FC:0.23 to 56,500FC
30