5) Confirm that the channel (or quad-triggering zone) numbers are the same for
the meter and the PocketWizard receiver.
6) Press the Measuring/OK button El. The flash will be triggered and a
measurement will be displayed.
(Note )
@ If the flash output power is too weak compared to the surrounding light, the meter may not
detect the flash output. In this case, use the "Cord Flash Mode" (See P21).
@Pulsed light sources such as fluorescent lights or special lighting could cause the meter to take
cordless flash measurements (in rare cases). The resulting reading will be incorrect. In these
situations it is recommended to take a measurement in "Cord Flash Mode" with a sync cord
attached to the meter and flash. (See P21)
@Because the light radiated from a flash bulb gradually builds, the meter will not detect the light
when used in Cordless Flash Mode. Be sure to use the "Cord Flash Mode" (See P21) in this case.
@ If the light source illumination is too bright or not bright enough, or if color temperature is out of
the measurement range, when the Measuring/OK button Hl is pressed, [&, Auer] or [L Under]
will blink to indicate that measurements cannot be made. In this case, adjust the brightness or
color temperature, or switch the flash measurement range. (See P28)
@ If you need to compensate the indicated value on LCD screen, you can recall saved preset White
Balance/Color Compensation and apply those settings to the indicated values. (See P16)