Ceiling Microphone (Cm-01) Mounting Detail - Shure EXHIBIT 212 Manual

Table of Contents

Advertisement

Case: 1:17-cv-03078 Document #: 901-3 Filed: 08/12/20 Page 587 of 609 PageID #:48603

Ceiling Microphone (CM-01) Mounting Detail

(Note, ceiling microphones should not be mounted in ceilings higher than 10 feet without consulting CTG
support)
STEP 1
Wire Phoenix Terminal
Block to end of cable run
from the FS-400/800
microphone input and
plug into connection
module.
STEP 2
Drill ½" hole in the tile at
desired location. Push
microphone barrel, with
attached 18" cable and
mini XLR connector up
through ½" hole in tile
until lip stops against tile.
Secure on top of tile with
friction clip.
STEP 3
Plug mini XLR connector at
end of 18" cable into male
jack on connection module.
Rest connection module on
top of tile.
Page 8 of 26