WARNING: Gauge manifold sets, hoses,
recovery cylinders and the recovery machine
must be rated for the higher pressures
encountered with R-410A. An attempt to use
standard refrigerant service tools on R-410A
systems is very dangerous and foolish. Such a
mistake could cause serious injury or death.
Tap Valve
Part number WX5X328 tap valve is used to tap
the sealed system for R-410A recovery. The
recommended placement of the tap is the
process stub at the outlet of the condenser.
R-410A Recovery Pump
The recovery pump must have an EPA
certification notice showing the use for
designated refrigerants include R-410A. The
high side gauge should read up to 800 psi.
R-410A Recovery Cylinder
Recovery cylinders must be rated for R-410A use.
These cylinders, DOT-4BA 400 or DOT-4BW 400,
meet the Department of Transportation standards
for R-410A recovery cylinders. Be very careful. It
would be easy and convenient to use whatever
recovery cylinder was handy rather than the
correct cylinder. This is a safety issue of great
concern to the industry and is one reason the
AC&R Safety Coalition was formed, and R-410A
Safety and Handling certification was established.
In-Line Filter
The recovery pump can be exposed to debris
that can damage it. Contamination can also be
introduced from the refrigerant storage tanks. An
in-line filter, such as the Catch All C-032, is to be
used for all refrigerants, including 410A. Change
the in-line filter as needed.
R-410A Gauge Manifold Set
R-410A systems require higher pressure gauges
and hoses. Look for R-410A printed on the
center of the dial. The high side pressure gauge
should read up to 800 psi and the low side up to
500 psi.
Digital Refrigerant Scale
A CPS® Compute-a-Charge CC220 digital scale
is used when charging R-410A.
R-410A Refrigerant Cylinder
For instant identification, all brands of R-410A are
shipped in a rose-colored tank.
R410 Rated Tools
R-410A Recovery Pump
with 800 psi gauge
for the High Side
In-Line Filter
No. WX10X10003
Digital
Refrigerant Scale
#CC220
– 52 –
Tap Valve
R-410A Recovery Cylinder
DOT–4BA400 or
DOT–4BW400
R-410A Cylinder
Gauge Manifold
R4 1 0 a
R-410A Refrigerant

Advertisement