Haier AB142FCAHA Operation And Installation Manual
Haier AB142FCAHA Operation And Installation Manual

Haier AB142FCAHA Operation And Installation Manual

Cassette type air conditioner
Hide thumbs Also See for AB142FCAHA:

Advertisement

Quick Links

CASSETTE TYPE AIR CONDITIONER
Operation & Installation
Manual
No.0010573643
B
Please read this operation manual before using the air conditioner.
Please keep this manual carefully and safely.

Advertisement

Table of Contents
loading

Summary of Contents for Haier AB142FCAHA

  • Page 1 CASSETTE TYPE AIR CONDITIONER Operation & Installation Manual No.0010573643 Please read this operation manual before using the air conditioner. Please keep this manual carefully and safely.
  • Page 2: Table Of Contents

    Contents Cautions ... Introduction to Spare Parts ... Maintenance ... Trouble Shooting ... When Trouble Happens ... Customer Need-to-know ... Installation Procedure ... 12-19...
  • Page 3: Cautions

    Damaged air conditioners are not to be put into operation. In case of doubt, consult your supplier. Use of the air conditioner is to be carried out in strict compliance with the relative instructions set forth in the User's Guide.
  • Page 4 Do not obstruct or cover the ventilation grille of the air conditioner. Do not put fingers or any other things into the inlet/outlet and swing louver. Do not allow children to play with the air conditioner.
  • Page 5 Cautions Safety cautions Carefully read the following information in order to operate the airconditioner correctly. Below are listed three kinds of Safety Cautions and Suggestions. WARNING! Incorrect operations may result in severe consequences of death or serious injuries. CAUTION! Incorrect operations may result in injuries or machine damages; in some cases may cause serious consequences.
  • Page 6: Cautions

    Cautions Conditioner should not be used for any other purpose other than airconditioning. Don't use air-conditioner for any other special purposes, e.g. the preservation and protection of food, animals, plants, pecision apparatus as well as work of art, otherwise the qualities of these stuffs may be damaged.
  • Page 7: Introduction To Spare Parts

    Introduction to Spare Parts Air Inlet Grille Air Filter (Inside of the Inlet Grille) Swing louver (Air flow direction can be adjusted by using the SWING button on the remote controller) Electrical Components Case...
  • Page 8: Maintenance

    Maintenance Clean the unit Turn off the power supply switch NOTE: The 4 fixed bolts must be loosed as shown in the figure by arrow if they are bolts, the method is that: push the blots inward till to another edge. Generally the fixed blots are opened for inlet grille easily up and down as well cheaning the air filter.After open it,lower the inlet grille using...
  • Page 9: Maintenance

    Stop operation and turn off the power supply switch .Electric power is consumed even the air conditioner is in stop. Clean the air filter, indoor unit and outdoor unit,and cover the unit with dustcoat.
  • Page 10: Trouble Shooting

    When the air conditoner is started, when the compressor starts or stops during operation or when the air conditioner is stopped,it som- etimes sounds ì Bi- Bi-î or ìGodo-Godoî. It is the flowing sound of the refrigerant , not a malfunction.
  • Page 11: Trouble Shooting

    During heating,indoor fan is still running even unit is stopped. Please check the following things about your air conditioner before making a service call. Is the power supply switch on ? Power supply switch is not in ON position.
  • Page 12: When Trouble Happens

    Insufficient cooling Sunlight direct into the room ? When the air conditioner does not operate properly after you have checked the above-mentioned items or when following phenomenon is observed,stop the operation of the air conditioner and contact your sales dealer.
  • Page 13: Customer Need-To-Know

    Customer Need-to-know Customer Need-to-know Please install the air conditioner according to the requirements specified in this manual to ensure the air conditioner work well. Be careful not to scratch the surface of the case during moving the air conditioner. Please keep the installation manual for future reference when maintenance and changing installation place.
  • Page 14: Installation Procedure

    Installation Procedure Installation Please call dealer to install the air-conditioner. Incorrect installation may cause water leaking, shock and fire hazard. Please ask the dealer or specialist to install, never try by the users themselves. After the installation please be sure of the following conditions. Air-conditioner can't be installed in the envi- ronment with inflammable gases because the inflammable gases near to air-conditioner may...
  • Page 15 Installation Procedure To ensure proper installation, read "Cautions" carefully before working. After CAUTIONS: installation, start the unit correctly and show customers how to operate and maintain the unit. Meanings of Warning and Cautions: Warning! Serious injury or even death might happen, if it is not observed. Caution! Injury to people of damages to machine might happen, if it is not observed.
  • Page 16: Installation Tools

    Installation Procedure Installation tools The installation tools listed in the following sheet can be used as required. 1. Screw driver 2. Hacksaw 3. Drill with a diameter of 60mm 4. Inner hexagon spanner,shifting spanner 5. Spanner (14, 17, 19,24,27mm) 6. Pipe cutter 7.
  • Page 17: Before Installation

    Installation Procedure 1. BEFORE INSTALLATION Determine the way to carry unit to installation place. Don't remove packing until unit reaches installation place. If unpacking is unkavoidable, protect unit properly. 2. SELECTION OF INSTALLATION PLACE (1) Installation place shall meet the following and agreed by customers: Place where proper air flow can be ensured.
  • Page 18 Installation Procedure 3. PREPARATION FOR THE INSTALLATION (1) Position of ceiling opening between unit and suspending bolt. Distance between suspending bolts 460mm 570(Indoor unit) 600(Ceiling opening) 630(Ornament panel) (2) Cut an opening in ceiling for installation if necessary. (when ceiling already exists.) Refer to paper pattern for dimension of ceiling hole.
  • Page 19 Installation Procedure 4. INSTALLATION OF INDOOR UNIT In the case of new ceiling (1) Install unit temporally Put suspending bracket on the suspending bolt. Be sure to use nut and washer at both ends of the bracket. As for the dimensions of ceiling hole, see paper pattern. Ask your real estate dealer for details. Center of the hole is marked on the paper pattern.
  • Page 20: Refrigerant Piping

    Installation Procedure 5. REFRIGERANT PIPING Outdoor is precharged with refrigerant. Be sure to see the Fig.1, when connecting and removing piping from unit. For the size of the flare nut, please refer to Table 1. Apply refrigerant oil at both inside and outsid of lflare nut. Tighten it band tight 3-4 turns then tighten it. Use torque specified in Table 1.
  • Page 21: Installation Procedure

    Installation Procedure Check whether indoor unit is horizontal with leveler or polythene pipe filled with water , and check that the dimension of the ceiling opening is correct. Take off the lever gauge before install the ornament panel. Fasten the screws to make the height difference between the two sides of indoor unit less than 5mm.

This manual is also suitable for:

Ab182fcahaAb142fcbhaAb182fcbha

Table of Contents