Innova DS200 User Manual page 21

Channel graphing multimeter
Table of Contents

Advertisement

Voltage, Auxiliary Terminal:
DC Range
AC Range
Resolution
1000 mV
700 mV
300 nV
680 mV
475 mV
150 nV
510 mV
350 mV
100 nV
400 mV
275 mV
75 nV
290 mV
200 mV
50 nV
220 mV
150 mV
40 nV
150 mV
100 mV
25 nV
Diode Voltage Drop
Range
Resolution
Noise Floor
2.2 V
300 nV
10 µV
1.2 V
150 nV
5 µV
825 mV
100 nV
3.5 µV
625 mV
75 nV
2.5 µV
400 mV
50 nV
1.75 µV
300 mV
40 nV
1.25 µV
200 mV
25 nV
800 nV
Accuracy
Noise Floor
(%+count)
10 µV
0.5 + 20
5 µV
0.5 + 20
4 µV
0.5 + 20
3 µV
0.5 + 20
2 µV
0.5 + 20
2 µV
0.5 + 20
1 µV
0.5 + 20
Accuracy
1.0 + 50
1.0 + 50
1.0 + 50
1.0 + 50
1.0 + 50
1.0 + 50
1.0 + 50
Terminal
Surge Protection
6kV
V
800V
Ω
10kA 600V
A
General Specifications
Input Impedance
>100MΩ <200pF
>100MΩ <200pF
Burden Voltage
<20µV/mA