Down Panel
Reset
1.
V1 V2:DC Input
The solar POE switch can also be used as an ordinary switch, when the power input such as the
battery solar panel is not connected. V1, V2 any interface DC input 12-37V, the current maximum
10A, the device is a Ethernet switch; V1, V2 any interface DC input 37-57V, the current maximum
10A, the device is a POE switch. If both V1 and V2 ports supply power at the same time, select
the port with the highest voltage.
2. LED Indicators description
LED Indicators
BT:Battery
VOT:PoE Voltage normal
BOUT: Battery discharge
SUN: Solar energy input
BIN: Battery charging
Battery percentage
Alarm Output
Temperature
Terminal
Sensor Input
DIP Switch
Battery and Solar LED
Status
Description
On
Battery is connected
Off
Battery is disconnected
On
PoE Voltage normal
Off
PoE Voltage abnormal
Solid on
Battery is discharging and battery capacity is 15%
Off
End of battery discharge or no discharge
Blink
1/2S: Battery capacity is ≤15%
Solid on
Solar energy input is normal
Off
No solar energy input
1/2S: Solar energy is in delayed charging, the time is 10mins.
Blink
1/4S: Solar power voltage is wrong, stop charging
Solid on
Battery is charging and battery capacity is <98%
Off
Battery is charged fully or no charging
Blink
The battery is charging, and battery capacity is ≥98%
Solid on
Reference the battery capacity 25% 50% 75% 100%