Troubleshooting - Vinotemp WM-125C User Manual

Vinotemp wm-125c: user guide
Hide thumbs Also See for WM-125C:
Table of Contents

Advertisement

WINEMATE COOLING SYSTEMS ARE SEALED SYSTEMS THAT REQUIREDS A MINIMUM
1
OF SERVICE.
WARNING
:
UNPLUG UNIT BEFORE CLEANING
2
CLEAN THE EXHAUST GRILL AT LEAST 3-4 TIMES A YEAR.(RECOMMENDED WITH VACUUM)
3
THE UNIT MAY RUN CONSTANTLY OR CYCLE ON AND OFF FOR SHORT PERIODS.
4
THE TIME REQUIRED TO REACH THE DESIRED TEMPERATURE WILL VARY, DEPENDING
ON THE ENCLOSURE CONSTRUCTIONS AND CONTENTS.
5
WINEMATE COOLING SYSTEM ARE NOT FOR USE BELOW 50F. AND WORK BEST AT 55F
TO 60F
PROBLEM
NOT RUNING
STILL DOES NOT START
RUNNING WARM
RUNS ALL THE TIME
STILL RUNS WARM
RUNNING TO COLD
STILL RUNS TO COLD
EXCESS MOISTURE
IN WINE CELLAR
TROUBLE SHOOTING
CHECK
POWER TO OUTLET
IS WINE CELLAR PLUGGED IN
IS UNIT PLUG IN
IS THERE DF DISPLAY ON DIGITAL
CHECK FOR 15 MIN.& SEE IF UNIT ITS CYCLE WORKING NORMAL
UNIT TURNS ON ON OFF
IS CONDESOR DIRTY
IS UNIT ICED UP
PROPER CLEARANCE FROM WALL
CHECK WINE CELLAR FOR AIR LEAKS
UNIT TURNS ON AND OFF
CHECK WINE CELLAR FOR AIR LEAKS AND
DOORS SEALS
PAGE 3
REMEDY
RESET CIRCUIT BREAKER
PLUG IN
PLUG IN INSIDE OF WINE CELLAR
UNIT IN DEFROST 30 MIN MAX
CALL SERVICE
ADJUST DIGITAL TO COLDER STTING
CLEAN CONDENSOR
DEFROST AND CHECK FOR AIR FLOW
OR ITS SET TO COLD
EXHAUST 6" FROM WALL ALL AROUND
REPAIR AIR LEAKS
CALL SERVICE
ADJUST DIGITAL TO WARMER SETTING
CALL SERVICE
REPAIR AIR LEAKS OR SEAL DOORS

Advertisement

Table of Contents
loading

Table of Contents