Unpacking - Master 60VMHD-GFA User's Manual & Operating Instructions

Propane forced air heater
Table of Contents

Advertisement

WARNING
WARNING
with a three-prong (grounding) plug for your
protection against shock hazard and should
be plugged directly into a properly grounded
three-prong receptacle.
WARNING
ALWAYS install the heater so that it is not directly exposed
to water spray, rain, dripping water, or wind.
Use heater in accordance with all local codes. In
the absence of local codes, refer to The National
Fuel Code, ANSI A223.1/NFPA 54.
This heater is shipped from the factory for use
with propane (LP) gas only. Do not convert to
any other gas. Installation must conform to local
codes, or in their absence, with the standard for
the Storage and Handling of Liquefied Petroleum
Gases ANSI/NFPA 58 and the Natural Gas and
Propane Installation Code CSA B149.1.
Gas supply connections should be checked by
using a 50/50 soap and water solution. Never use a
WARNING
Figure 1
1.
Remove all packing items applied to heater for
shipment. Keep plastic cover caps attached to inlet
connector and hose / regulator assembly for storage.
2. Remove all items from carton
3. Check all items for shipping damage. If the heater
is damaged, promptly inform dealer where you
purchased the heater.
© 2023 Pinnacle Climate Technologies, Inc.
NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR
WHILE CONNECTED TO A POWER SOURCE
SAFETY INFORMATION (CONT.)
RISK OF ELECTRIC
SHOCK!
Electrical Grounding
Instructions: This ap-
pliance is equipped
For use with propane
(LP) gas only.
RISK OF FIRE! DO NOT POSITION HEATER IN A DOWNWARD ANGLE.
ALWAYS LOCATE HEATER ON A STABLE AND LEVEL SURFACE (SEE
FIGURE 1)!

UNPACKING

flame to check for gas leaks.
Locate LP cylinder at least 6 ft. (183 cm) (10 ft./305
cm in Canada) from the heater, and do not direct
heater discharge towards the LP cylinder unless it
is at least 20 feet (610 cm) from the heater.
Use only the regulator and hose assembly provided
with this heater. Inspect the regulator/hose
assembly prior to each use of the heater. If there
is excessive abrasion or wear, or if the hose is cut,
replace it with the proper assembly shown in the
parts list, prior to using the heater.
The hose assembly shall be visually inspected
prior to each use of the heater. If it is evident there
is excessive abrasion or wear, or the hose is cut, it
shall be replaced prior to the heater being put into
operation. The replacement hose assembly shall
be that specified by the manufacturer.
Manifold, Minimum, and Maximum Inlet Pressure
60VMHD-GFA
Man.
11" (279 mm) W.C.
Min.
Max.
WARNING
ing material and contact with hot surfaces both
during use and while in storage.
X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X
X
CAUTION
sembly supplied with the heater must be used
without alteration.
5
Propane Forced Air Heater User's Manual
150VMHD-GFA
8" (203 mm) W.C.
5 PSI (34.5 kPa)
Bottle Pressure
The hose assembly
shall be pro tected
from traffic, build-
The Propane (LP)
gas pressure regu-
lator and hose as-

Advertisement

Table of Contents
loading

This manual is also suitable for:

150vmhd-gfa

Table of Contents