2-9-3. Actions to Be Taken when Inspection Resulted in Failure

Perform the following procedure for checking.
1.
Check that no dust is present on the battery cover, memory card / connector cover and the packing of the cabinet.
Check whether the vacuum pad is free of dust.
Furthermore, pay attention to the following.
In an environment with large vibration, the vacuum pad may stir and the inspection may be decided to be a failure. Carry
out air leak test in an environment with no vibration.
Hold the metal part at the end of the nozzle of the air leak tester and do not touch the tube of the air leak tester during the
air leak test.
Metal part
Check that the microphone hole is covered with a Kapton tape, and that the Kapton tape is firmly stuck with no dust.
2.
Check the assembling of the cabinet and make the measurement again.
3.
If the situation is still not improved after the above checking, replace the waterproof Assy and then make the measurement again.