Sony Cyber-shot DSC-RX0M2 Service Manual page 35

Hide thumbs Also See for Cyber-shot DSC-RX0M2:
Table of Contents

Advertisement

2019/05/15 01:58:50 (GMT+09:00)
3.
Press the hand pump slightly so that the indicated pressure value becomes to "-5.0".
Few seconds later, decrease the pressure slightly. Therefore adjust the indicated pressure by pressing the hand pump.
Note
Perform the pressure adjustment by hand pump pushing amount. If the pressure becomes too high,
perform the adjustment again after removing the vacuum pad.
4.
The change value is getting settle, wait 60 seconds with keeping the pressure at around the -5.0 kPa (within -0.0 kPa to -10.0
kPa), and record the indicated value (A).
CAUTION
Do not operate the hand pump after settling the change value.
If operate the hand pump again, wait 60 seconds form then.
5.
Leave the air leak tester for another 60 seconds, and record the indicated value (B).
Indicated
Air
value
pressure
-10.0kPa
-50.0kPa
-5.0kPa
-45.0kPa
-0.0kPa
-40.0kPa
FFF
Vacuum by hand pump
60sec
0kPa
Stop hand pump
(A)
(B)
60sec
Measurement
Measure this amount of change.
Displayed values at measurement
points (A) and (B) are entered in
"AirLeak_CheckTool.exe"
to determine them.
Measure between -0.0 to -10.0
Sony CONFIDENTIAL
For Authorized Servicer
27