2019/05/15 01:58:50 (GMT+09:00)
8.
Leave the air leak tester for another 60 seconds, and record the indicated value (D).
CAUTION
Do not open the battery cover for 120 seconds after the leak test.
Indicated
Air
value
pressure
-10.0kPa
-50.0kPa
-5.0kPa
-45.0kPa
-0.0kPa
-40.0kPa
FFF
Air switch: open
Deciding Measured Values
1.
Make decision of measured values using "AirLeak_CheckTool.exe".
Enter each measured value in indicated locations of the window.
Enter the value measured by the
air leak tester after 60 seconds.
Enter the value measured
by the unit after 60 seconds.
(C)
30sec
30sec
0kPa
Measurement
Air switch: close
Enter the value measured by
the air leak tester after 120 seconds.
Measure this amount of change.
Displayed values at measurement
points (C) and (D) are entered in
"AirLeak_CheckTool.exe"
(D)
to determine them.
60sec
Enter the value measured by
the unit after 120 seconds.
Sony CONFIDENTIAL
For Authorized Servicer
25
SYS SET