Page 3
Pickering Interfaces strives to fulfil all relevant environmental laws and regulations and reduce wastes and releases to the environment. Pickering Interfaces aims to design and operate products in a way that protects the environment and the health and safety of its employees, customers and the public. Pickering Interfaces endeavours to develop and manufacture products that can be produced, distributed, used and recycled, or disposed of, in a safe and environmentally friendly manner.
If this product is heavy reference should be made to the safety instructions for provisions of lifting and moving. STATIC SENSITIVE To indicate that static sensitive devices are present and handling precautions should be followed. REED RELAY MODULE 40-110/115/120/125 VERY HIGH DENSITY VERSATILE 2-POLE MUX MODULE 40-613A Page (IV) Page (IV)
Not to be used in safety critical circuits, refer to the Pickering Interfaces’ terms & conditions of sale. This module must not be used for the switching of Mains Circuits. For the switching of voltages up to the module’s full specification, Secondary Circuit power supplies and the Device Under Test must...
Page 8
• For suitably equipped products in the event of an emergency press the red “emergency stop” button situated on the front of the unit. VERY HIGH DENSITY VERSATILE 2-POLE MUX MODULE 40-613A Page (VIII) 2 AMP 1-POLE UHD MATRIX MODULES 40-575 / 576 / 577 / 578 / 579...
Page 9
Larger multiplexers may be constructed by daisy 4:1 MUX chaining the common signals from multiple modules. Com 7 The 40-613A can be operated as a conventional multiplexer 4:1 MUX Com 8 with break-before-make action when a new channel is selected.
Page 10
Com 7.1 25.1 MUX7 Com 7.2 28.2 Com 16.1 61.1 MUX16 Com 16.2 64.2 Detailed Switching Diagram for the 40-613A-002 Very High Density 16 Bank, 4 Channel, 2-Pole Versatile Multiplexer pickeringtest.com VERY HIGH DENSITY VERSATILE 2-POLE MUX MODULE 40-613A Page 1.2...
Page 11
† Path resistance & thermal offset are dependent upon the signal route selected. Power Requirements +3.3 V +5 V +12 V -12 V 5m A 2 A max (typ 280 mA) 0 pickeringtest.com VERY HIGH DENSITY VERSATILE 2-POLE MUX MODULE 40-613A Page 1.3...
Page 12
During configuration setting, all relay control information is logged in a text file which can be re-used in a programming environment. Soft Front Panel for the 40-613A Very High Density 2-Pole Versatile Multiplexer pickeringtest.com VERY HIGH DENSITY VERSATILE 2-POLE MUX MODULE 40-613A...
Page 13
We provide a full range of supporting cable and connector solutions for all our switching products—20 connector families with 1200+ products. We offer everything from simple mating connectors to complex cables assemblies and terminal blocks. All assemblies are manufactured by Pickering and are guaranteed to mechanically and electrically mate to our modules. Connectors & Backshells...
Page 14
Very High Density Versatile MUX, 40-613 Programming Pickering provide kernel, IVI and VISA (NI & Keysight) drivers which are compatible with all Microsoft supported versions of Windows and popular older versions. For a list of all supporting operating systems, please see: pickeringtest.com/os...
Modular products require installation in a suitable PXI/LXI chassis. The module is designed for indoor use only. PREOPERATION CHECKS (UNPACKING) 1. Check the module for transport damage and report any damage immediately to Pickering Interfaces. Do not attempt to install the product if any damage is evident.
For a system comprising more than one chassis, turn ON the last chassis in the system followed by the penultimate, etc, and finally turn ON the external controller or chassis containing the system controller. 9. For Pickering Interfaces modular LXI installation there is no requirement to use any particular power up sequence.
Figure 3.2 - General Soft Front Panel Icon A selector panel will appear, listing all installed Pickering PCI, PXI or LXI switch cards and resistor cards. Click on the card you wish to control, and a graphical control panel is presented allowing operation of the card.
Page 20
SECTION 3 - INSTALLATION pickering THIS PAGE INTENTIONALLY BLANK VERY HIGH DENSITY VERSATILE 2-POLE MUX MODULE 40-613A Page 3.4...
SECTION 4 - PROGRAMMING GUIDE PROGRAMMING OPTIONS FOR PICKERING INTERFACES PXI MODULES For information on the installation and use of drivers and the programming of Pickering’s products in various software environments, please refer to the Software User Manual. This is available as a download from: https://www.pickeringtest.com/support/software-drivers-and-downloads...
Com 8.2 RL36 TO RL39 32.2 Figure 4.1 - 40-613A Relay Switching Schematic (MUX banks 1 to 8), programming sub-unit numbers are shown in blue, bit numbers within a sub-unit are circled in red. VERY HIGH DENSITY VERSATILE 2-POLE MUX MODULE 40-613A...
Page 23
Com 16.2 RL76 TO RL77 64.2 Figure 4.2 - 40-613A Relay Switching Schematic (MUX banks 9 to 16), programming sub-unit numbers are shown in blue, bit numbers within a sub-unit are circled in red. VERY HIGH DENSITY VERSATILE 2-POLE MUX MODULE 40-613A...
Page 24
Bank 11, Channel 2 MUX(4)* Channel Bank 11, Channel 3 MUX(4)* Channel Bank 11, Channel 4 * For modules with multi-channel selection capability (“-M” ordering option) the sub-unit type will be “MUXM(4)” VERY HIGH DENSITY VERSATILE 2-POLE MUX MODULE 40-613A Page 4.4...
Page 25
* For modules with multi-channel selection capability (“-M” ordering option) the sub-unit type will be “MUXM(4)” Note 1:- Bank references listed above relate to an 16-bank configuration, for varients the bank identifiers will change. VERY HIGH DENSITY VERSATILE 2-POLE MUX MODULE 40-613A Page 4.5...
PIL_SubType, PIL_SubInfo pilpxi For further detail of how to access and use Pickering drivers the user is advised to refer to the documentation provided with the installed drivers. Programming Examples Here are some simple examples of using the drivers with the 40-613A-002 1/64/2 Multiplexer module.
Page 34
The following configurations are provided in the pi40iv.ini driver configuration file in your installation. Use one of these strings in the InitWithOptions function. The format of the string is 40-613A-002-(bank)((channel)x1) as shown below:...
SOFT FRONT PANEL The Versatile Multiplexer Soft Front Panel for the 40-613A-002 allows easy setting of various configurations from a 16-bank 4-channel 2-pole multiplexer, up to a 1-bank 64-channel 2-pole multiplexer as well as individual relay con- trol for custom configurations. The schematic in the background of the SFP simplifies understanding of the selected topology.
Page 36
SECTION 4 - PROGRAMMING GUIDE pickering THIS PAGE INTENTIONALLY BLANK VERY HIGH DENSITY VERSATILE 2-POLE MUX MODULE 40-613A Page 4.16...
Page 37
40-613A Pin Designations - IVI Modes The 40-613A has a number of modes of operation when controlled through IVI where the MUX can be set to a specified configuration. The tables on the following pages apply to each of the IVI mode settings. For more information on the IVI modes see the IVI section in the programming chapter of this manual.
Page 38
Figure 5.2 - Multiplexer Module 40-613A: IVI mode corresponding to 16-Bank, 4-Channel, 2-Pole pin designations. The pin designations shown correspond to the IVI port. VERY HIGH DENSITY VERSATILE 2-POLE MUX MODULE 40-613A Page 5.2...
Page 39
Figure 5.3 - Multiplexer Module 40-613A: IVI mode corresponding to 8-Bank, 8-Channel, 2-Pole pin designations. The pin designations shown correspond to the IVI port. VERY HIGH DENSITY VERSATILE 2-POLE MUX MODULE 40-613A Page 5.3...
Page 40
Figure 5.4 - Multiplexer Module 40-613A: IVI mode corresponding to 4-Bank, 16-Channel, 2-Pole pin designations. The pin designations shown correspond to the IVI port. VERY HIGH DENSITY VERSATILE 2-POLE MUX MODULE 40-613A Page 5.4...
Page 41
Figure 5.5 - Multiplexer Module 40-613A: IVI mode corresponding to 2-Bank, 32-Channel, 2-Pole pin designations. The pin designations shown correspond to the IVI port. VERY HIGH DENSITY VERSATILE 2-POLE MUX MODULE 40-613A Page 5.5...
Page 42
Figure 5.6 - Multiplexer Module 40-613A: IVI mode corresponding to 1-Bank, 64-Channel, 2-Pole pin designations. The pin designations shown correspond to the IVI port. VERY HIGH DENSITY VERSATILE 2-POLE MUX MODULE 40-613A Page 5.6...
PCI configuration, highlighting any potential configuration problems. Specific details of all installed Pickering switch cards are included. All the installed Pickering switch cards should be listed in the “Pilpxi information” section - if one or more cards is missing it may be possible to determine the reason by referring to the PCI configuration dump contained in the report, but interpretation of this information is far from straightforward, and the best course is to contact Pickering support: support@pickeringtest.com, if possible...
Page 44
SECTION 6 - TROUBLE SHOOTING pickering THIS PAGE INTENTIONALLY BLANK VERY HIGH DENSITY VERSATILE 2-POLE MUX MODULE 40-613A Page 6.2...
For PXI modules which are supported in one of Pickering Interfaces’ Modular LXI Chassis (such as the 60-102B and 60-103B) no module software update is required. If the module was introduced after the LXI chassis was manufactured the module may not be recognized, in this case the chassis firmware may need upgrading.
Need help?
Do you have a question about the 40-613A and is the answer not in the manual?
Questions and answers