Pickering 40-613A User Manual

Pickering 40-613A User Manual

Pxi very high density versatile 2-pole multiplexer

Advertisement

Quick Links

40-613A User Manual
PXI Very High Density Versatile 2-Pole Multiplexer
pickeringtest.com
Issue 1.3 April 2021

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 40-613A and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Pickering 40-613A

  • Page 1 40-613A User Manual PXI Very High Density Versatile 2-Pole Multiplexer pickeringtest.com Issue 1.3 April 2021...
  • Page 2 © COPYRIGHT (2021) PICKERING INTERFACES. ALL RIGHTS RESERVED. No part of this publication may be reproduced, transmitted, transcribed, translated or stored in any form, or by any means without the written permission of Pickering Interfaces. Technical details contained within this publication are subject to change without notice.
  • Page 3 Pickering Interfaces strives to fulfil all relevant environmental laws and regulations and reduce wastes and releases to the environment. Pickering Interfaces aims to design and operate products in a way that protects the environment and the health and safety of its employees, customers and the public. Pickering Interfaces endeavours to develop and manufacture products that can be produced, distributed, used and recycled, or disposed of, in a safe and environmentally friendly manner.
  • Page 4: Product Safety

    If this product is heavy reference should be made to the safety instructions for provisions of lifting and moving. STATIC SENSITIVE To indicate that static sensitive devices are present and handling precautions should be followed. REED RELAY MODULE 40-110/115/120/125 VERY HIGH DENSITY VERSATILE 2-POLE MUX MODULE 40-613A Page (IV) Page (IV)
  • Page 5: Table Of Contents

    Soft Front Panel ..............4.15 Section 5 Connector Information ..............5.1 Section 6 Trouble Shooting .................6.1 Section 7 Maintenance Information ............7.1 Switching System Test Tools ..........7.1 Relay Lookup Tables ............7.1 Component Layout ..............7.3 VERY HIGH DENSITY VERSATILE 2-POLE MUX MODULE 40-613A Page (V)
  • Page 6 THIS PAGE INTENTIONALLY BLANK VERY HIGH DENSITY VERSATILE 2-POLE MUX MODULE 40-613A Page (VI)
  • Page 7: Warnings And Cautions

    Not to be used in safety critical circuits, refer to the Pickering Interfaces’ terms & conditions of sale. This module must not be used for the switching of Mains Circuits. For the switching of voltages up to the module’s full specification, Secondary Circuit power supplies and the Device Under Test must...
  • Page 8 • For suitably equipped products in the event of an emergency press the red “emergency stop” button situated on the front of the unit. VERY HIGH DENSITY VERSATILE 2-POLE MUX MODULE 40-613A Page (VIII) 2 AMP 1-POLE UHD MATRIX MODULES 40-575 / 576 / 577 / 578 / 579...
  • Page 9 Larger multiplexers may be constructed by daisy 4:1 MUX chaining the common signals from multiple modules. Com 7 The 40-613A can be operated as a conventional multiplexer 4:1 MUX Com 8 with break-before-make action when a new channel is selected.
  • Page 10 Com 7.1 25.1 MUX7 Com 7.2 28.2 Com 16.1 61.1 MUX16 Com 16.2 64.2 Detailed Switching Diagram for the 40-613A-002 Very High Density 16 Bank, 4 Channel, 2-Pole Versatile Multiplexer pickeringtest.com VERY HIGH DENSITY VERSATILE 2-POLE MUX MODULE 40-613A Page 1.2...
  • Page 11 † Path resistance & thermal offset are dependent upon the signal route selected. Power Requirements +3.3 V +5 V +12 V -12 V 5m A 2 A max (typ 280 mA) 0 pickeringtest.com VERY HIGH DENSITY VERSATILE 2-POLE MUX MODULE 40-613A Page 1.3...
  • Page 12 During configuration setting, all relay control information is logged in a text file which can be re-used in a programming environment. Soft Front Panel for the 40-613A Very High Density 2-Pole Versatile Multiplexer pickeringtest.com VERY HIGH DENSITY VERSATILE 2-POLE MUX MODULE 40-613A...
  • Page 13 We provide a full range of supporting cable and connector solutions for all our switching products—20 connector families with 1200+ products. We offer everything from simple mating connectors to complex cables assemblies and terminal blocks. All assemblies are manufactured by Pickering and are guaranteed to mechanically and electrically mate to our modules. Connectors & Backshells...
  • Page 14 Very High Density Versatile MUX, 40-613 Programming Pickering provide kernel, IVI and VISA (NI & Keysight) drivers which are compatible with all Microsoft supported versions of Windows and popular older versions. For a list of all supporting operating systems, please see: pickeringtest.com/os...
  • Page 15: Functional Description

    U3, U4, U8 TO U12 U5, U6 TERMINATING BRIDGE RESISTORS R1 TO R12 MODULE CONFIGURATION PCI BRIDGE CONFIGURATION Figure 2.1 - Very High Density Versatile 2-Pole MUX 40-613A: Functional Block Diagram VERY HIGH DENSITY VERSATILE 2-POLE MUX MODULE 40-613A Page 2.1...
  • Page 16 SECTION 2 - TECHNICAL DESCRIPTION pickering THIS PAGE INTENTIONALLY BLANK VERY HIGH DENSITY VERSATILE 2-POLE MUX MODULE 40-613A Page 2.2...
  • Page 17: Installation

    Modular products require installation in a suitable PXI/LXI chassis. The module is designed for indoor use only. PREOPERATION CHECKS (UNPACKING) 1. Check the module for transport damage and report any damage immediately to Pickering Interfaces. Do not attempt to install the product if any damage is evident.
  • Page 18: Hardware Installation

    For a system comprising more than one chassis, turn ON the last chassis in the system followed by the penultimate, etc, and finally turn ON the external controller or chassis containing the system controller. 9. For Pickering Interfaces modular LXI installation there is no requirement to use any particular power up sequence.
  • Page 19: Testing Operation

    Figure 3.2 - General Soft Front Panel Icon A selector panel will appear, listing all installed Pickering PCI, PXI or LXI switch cards and resistor cards. Click on the card you wish to control, and a graphical control panel is presented allowing operation of the card.
  • Page 20 SECTION 3 - INSTALLATION pickering THIS PAGE INTENTIONALLY BLANK VERY HIGH DENSITY VERSATILE 2-POLE MUX MODULE 40-613A Page 3.4...
  • Page 21: Programming Guide

    SECTION 4 - PROGRAMMING GUIDE PROGRAMMING OPTIONS FOR PICKERING INTERFACES PXI MODULES For information on the installation and use of drivers and the programming of Pickering’s products in various software environments, please refer to the Software User Manual. This is available as a download from: https://www.pickeringtest.com/support/software-drivers-and-downloads...
  • Page 22: Module Architecture 40-613A

    Com 8.2 RL36 TO RL39 32.2 Figure 4.1 - 40-613A Relay Switching Schematic (MUX banks 1 to 8), programming sub-unit numbers are shown in blue, bit numbers within a sub-unit are circled in red. VERY HIGH DENSITY VERSATILE 2-POLE MUX MODULE 40-613A...
  • Page 23 Com 16.2 RL76 TO RL77 64.2 Figure 4.2 - 40-613A Relay Switching Schematic (MUX banks 9 to 16), programming sub-unit numbers are shown in blue, bit numbers within a sub-unit are circled in red. VERY HIGH DENSITY VERSATILE 2-POLE MUX MODULE 40-613A...
  • Page 24 Bank 11, Channel 2 MUX(4)* Channel Bank 11, Channel 3 MUX(4)* Channel Bank 11, Channel 4 * For modules with multi-channel selection capability (“-M” ordering option) the sub-unit type will be “MUXM(4)” VERY HIGH DENSITY VERSATILE 2-POLE MUX MODULE 40-613A Page 4.4...
  • Page 25 * For modules with multi-channel selection capability (“-M” ordering option) the sub-unit type will be “MUXM(4)” Note 1:- Bank references listed above relate to an 16-bank configuration, for varients the bank identifiers will change. VERY HIGH DENSITY VERSATILE 2-POLE MUX MODULE 40-613A Page 4.5...
  • Page 26 7 \ 4 15 \ 4 8 \ 1 16 \ 1 8 \ 2 16 \ 2 8 \ 3 16 \ 3 8 \ 4 16 \ 4 VERY HIGH DENSITY VERSATILE 2-POLE MUX MODULE 40-613A Page 4.6...
  • Page 27 15 \ 4 7 \ 4 16 \ 1 8 \ 1 16 \ 2 8 \ 2 16 \ 3 8 \ 3 16 \ 4 8 \ 4 VERY HIGH DENSITY VERSATILE 2-POLE MUX MODULE 40-613A Page 4.7...
  • Page 28 7 \ 4 15 \ 4 8 \ 1 16 \ 1 8 \ 2 16 \ 2 8 \ 3 16 \ 3 8 \ 4 16 \ 4 VERY HIGH DENSITY VERSATILE 2-POLE MUX MODULE 40-613A Page 4.8...
  • Page 29 7 \ 4 15 \ 4 8 \ 1 16 \ 1 8 \ 2 16 \ 2 8 \ 3 16 \ 3 8 \ 4 16 \ 4 VERY HIGH DENSITY VERSATILE 2-POLE MUX MODULE 40-613A Page 4.9...
  • Page 30 7 \ 4 15 \ 4 8 \ 1 16 \ 1 8 \ 2 16 \ 2 8 \ 3 16 \ 3 8 \ 4 16 \ 4 VERY HIGH DENSITY VERSATILE 2-POLE MUX MODULE 40-613A Page 4.10...
  • Page 31 Interbank Linking 17 \ 9 Interbank Linking 17 \ 10 Interbank Linking 17 \ 11 Interbank Linking 17 \ 13 Interbank Linking 17 \ 14 Interbank Linking 17 \ 15 VERY HIGH DENSITY VERSATILE 2-POLE MUX MODULE 40-613A Page 4.11...
  • Page 32 Interbank Linking 17 \ 10 Interbank Linking 17 \ 11 Interbank Linking 17 \ 12 Interbank Linking 17 \ 13 Interbank Linking 17 \ 14 Interbank Linking 17 \ 15 VERY HIGH DENSITY VERSATILE 2-POLE MUX MODULE 40-613A Page 4.12...
  • Page 33: Programming The 40-613A Module

    PIL_SubType, PIL_SubInfo pilpxi For further detail of how to access and use Pickering drivers the user is advised to refer to the documentation provided with the installed drivers. Programming Examples Here are some simple examples of using the drivers with the 40-613A-002 1/64/2 Multiplexer module.
  • Page 34 The following configurations are provided in the pi40iv.ini driver configuration file in your installation. Use one of these strings in the InitWithOptions function. The format of the string is 40-613A-002-(bank)((channel)x1) as shown below:...
  • Page 35: Soft Front Panel

    SOFT FRONT PANEL The Versatile Multiplexer Soft Front Panel for the 40-613A-002 allows easy setting of various configurations from a 16-bank 4-channel 2-pole multiplexer, up to a 1-bank 64-channel 2-pole multiplexer as well as individual relay con- trol for custom configurations. The schematic in the background of the SFP simplifies understanding of the selected topology.
  • Page 36 SECTION 4 - PROGRAMMING GUIDE pickering THIS PAGE INTENTIONALLY BLANK VERY HIGH DENSITY VERSATILE 2-POLE MUX MODULE 40-613A Page 4.16...
  • Page 37 40-613A Pin Designations - IVI Modes The 40-613A has a number of modes of operation when controlled through IVI where the MUX can be set to a specified configuration. The tables on the following pages apply to each of the IVI mode settings. For more information on the IVI modes see the IVI section in the programming chapter of this manual.
  • Page 38 Figure 5.2 - Multiplexer Module 40-613A: IVI mode corresponding to 16-Bank, 4-Channel, 2-Pole pin designations. The pin designations shown correspond to the IVI port. VERY HIGH DENSITY VERSATILE 2-POLE MUX MODULE 40-613A Page 5.2...
  • Page 39 Figure 5.3 - Multiplexer Module 40-613A: IVI mode corresponding to 8-Bank, 8-Channel, 2-Pole pin designations. The pin designations shown correspond to the IVI port. VERY HIGH DENSITY VERSATILE 2-POLE MUX MODULE 40-613A Page 5.3...
  • Page 40 Figure 5.4 - Multiplexer Module 40-613A: IVI mode corresponding to 4-Bank, 16-Channel, 2-Pole pin designations. The pin designations shown correspond to the IVI port. VERY HIGH DENSITY VERSATILE 2-POLE MUX MODULE 40-613A Page 5.4...
  • Page 41 Figure 5.5 - Multiplexer Module 40-613A: IVI mode corresponding to 2-Bank, 32-Channel, 2-Pole pin designations. The pin designations shown correspond to the IVI port. VERY HIGH DENSITY VERSATILE 2-POLE MUX MODULE 40-613A Page 5.5...
  • Page 42 Figure 5.6 - Multiplexer Module 40-613A: IVI mode corresponding to 1-Bank, 64-Channel, 2-Pole pin designations. The pin designations shown correspond to the IVI port. VERY HIGH DENSITY VERSATILE 2-POLE MUX MODULE 40-613A Page 5.6...
  • Page 43: Trouble Shooting

    PCI configuration, highlighting any potential configuration problems. Specific details of all installed Pickering switch cards are included. All the installed Pickering switch cards should be listed in the “Pilpxi information” section - if one or more cards is missing it may be possible to determine the reason by referring to the PCI configuration dump contained in the report, but interpretation of this information is far from straightforward, and the best course is to contact Pickering support: support@pickeringtest.com, if possible...
  • Page 44 SECTION 6 - TROUBLE SHOOTING pickering THIS PAGE INTENTIONALLY BLANK VERY HIGH DENSITY VERSATILE 2-POLE MUX MODULE 40-613A Page 6.2...
  • Page 45: Maintenance Information

    For PXI modules which are supported in one of Pickering Interfaces’ Modular LXI Chassis (such as the 60-102B and 60-103B) no module software update is required. If the module was introduced after the LXI chassis was manufactured the module may not be recognized, in this case the chassis firmware may need upgrading.
  • Page 46 TABLE 7.3 - 4-Bank, 16-Channel, 2-Pole: Relay Numbering Relays Operated Bank Channel Selection Interbank 1-4, 6-9, 11-14, 5,10,15 16-19 21-24, 26-29, 25,30,35 31-34, 36-39 41-44, 46-49, 45,50,55 51-54, 56-59 61-64, 66-69, 65,70,75 71-74, 76-79 VERY HIGH DENSITY VERSATILE 2-POLE MUX MODULE 40-613A Page 7.2...
  • Page 47 Bank Channel Selection Interbank 1-4, 6-9, 11-14, 16-19, 21-24, 26-29, 5,10,15,20,25,30,35 31-34, 36-39, 41-44, 46-49, 51-54, ,40,45,50,55,60,65, 56-59, 61-64, 66-69, 71-74, 76-79 70,75 Figure 7.1 - Multiplexer Module: Component Layout VERY HIGH DENSITY VERSATILE 2-POLE MUX MODULE 40-613A Page 7.3...
  • Page 48 SECTION 7 - MAINTENANCE INFORMATION pickering Figure 7.2 - Multiplexer Module: 40-613A VERY HIGH DENSITY VERSATILE 2-POLE MUX MODULE 40-613A Page 7.4...

Table of Contents