Page 3
Pickering Interfaces strives to fulfil all relevant environmental laws and regulations and reduce wastes and releases to the environment. Pickering Interfaces aims to design and operate products in a way that protects the environment and the health and safety of its employees, customers and the public. Pickering Interfaces endeavours to develop and manufacture products that can be produced, distributed, used and recycled, or disposed of, in a safe and environmentally friendly manner.
To indicate that static sensitive devices are Pour indiquer que des appareils sensibles present and handling precautions should be statiques sont présents et les précautions de followed. manipulation doivent être suivies. VERY HIGH DENSITY MULTIPLEXER MODULE 40-610A REED RELAY MODULE 40-110/115/120/125 Page (IV) Page (IV)
Blanking panels are signaux d’E/S utilisateur qui peuvent être présents. available to order from Pickering in a variety of slot Les obturateurs sont disponibles sur commande chez widths. If the product is not used in this manner for Pickering dans une variété...
Page 8
“arrêt an emergency press the red “emergency stop” d’urgence” situé sur l’avant de l’unité. button situated on the front of the unit. GENERAL PURPOSE 2A RELAY MODULE 40-131/132 Page (VIII) VERY HIGH DENSITY MULTIPLEXER MODULE 40-610A Page (VIII)
200-pin LFH socket. suitable for improved noise performance. Available Multiplexer Formats The 40-610A is part of a family of high density PXI multiplexer 8 Banks, 16 Channels, 1-Pole modules that share a similar architecture and the same 200-pin...
Page 10
• 4 Banks of 16 Channels Switch • 2 Banks of 32 Channels • 1 Bank of 64 Channels • Custom Configurations PCB Layout for the 40-610A Very High Density Multiplexer Module pickeringtest.com VERY HIGH DENSITY MULTIPLEXER MODULE 40-610A Page 1.2...
Page 11
Specifications Very High Density MUX, 40-610A Relay Type Mechanical Characteristics The 40-610A is fitted with high quality reed telays, Single slot 3U PXI (CompactPCI card). these offer very long life with good low level switching Module weight: 220 g (40-610A-001).
Page 12
40-610A-009-M Mating Connectors & Cabling Note: 40-610A-009/10/11/12 modules can be factory For connection accessories for the 40-610A series please reconfigured into any of the above configurations. refer to the 90-002D 200-pin LFH Connector Accessories...
Page 13
We provide a full range of supporting cable and connector solutions for all our switching products—20 connector families with 1200+ products. We offer everything from simple mating connectors to complex cables assemblies and terminal blocks. All assemblies are manufactured by Pickering and are guaranteed to mechanically and electrically mate to our modules. Connectors & Backshells...
Page 14
Very High Density MUX, 40-610A Programming Pickering provide kernel, IVI and VISA (NI & Keysight) drivers which are compatible with all Microsoft supported versions of Windows and popular older versions. For a list of all supporting operating systems, please see: pickeringtest.com/os...
CONFIGURATION 2 POLE MUX SINGLE POLE MUX SINGLE POLE SCREENED MUX ISOLATION ISOLATION ISOLATION SWITCHES SWITCH SWITCH COMMON COMMON COMMON Figure 2.1 - Very High Density Multiplexer Module 40-610A: Functional Block Diagram VERY HIGH DENSITY MULTIPLEXER MODULE 40-610A Page 2.1...
Page 16
SECTION 2 - TECHNICAL DESCRIPTION pickering THIS PAGE INTENTIONALLY BLANK VERY HIGH DENSITY MULTIPLEXER MODULE 40-610A Page 2.2...
VII. à la Page VII. Ensure that there is adequate ventilation. Assurez-vous que la ventilation est adéquate. VERY HIGH DENSITY MULTIPLEXER MODULE 40-610A REED RELAY MODULE 40-110/115/120/125 Page 3.1 Page 3.1...
Page 18
9. For Pickering Interfaces modular LXI installation b. Pour un système comprenant plus d’un châssis, there is no requirement to use any particular power allumez le dernier châssis dans le système up sequence.
Si vous n’êtes pas un utilisateur de LabVIEW, vous LabVIEW Runtime Engine installer via the shortcut devez choisir la version “complète”, et une fois qu’elle on the Programs>>Pickering menu. In the absence of a été installée. Lancer le programme d’installation LabVIEW the Runtime Engine is required to support LabVIEW Runtime Engine via le raccourci dans the Pickering Test Panels application.
Figure 3.2 - General Soft Front Panel Icon A selector panel will appear, listing all installed Pickering PCI, PXI or LXI switch cards and resistor cards. Click on the card you wish to control, and a graphical control panel is presented allowing operation of the card.
SECTION 4 - PROGRAMMING GUIDE PROGRAMMING OPTIONS FOR PICKERING INTERFACES PXI MODULES For information on the installation and use of drivers and the programming of Pickering’s products in various software environments, please refer to the Software User Manual. This is available as a download from: https://www.pickeringtest.com/support/software-drivers-and-downloads...
MODULE ARCHITECTURE 40-610A The 40-610A module is an array of up to 80 SPST reed relays factory configured as one of 16 different multiplexer configurations. In the default state, all multiplexer channels are open circuit. Energising a particular channel creates a signal path between the common terminal(s) and the corresponding channel terminal(s).
Page 23
SECTION 4 - PROGRAMMING GUIDE pickering Table 4.1 - Module Sub-Unit Details: 40-610A-001 8 Bank, 16 Channel, 1 Pole Isolation Isolation Bank Chan. Channel Bank Chan. Channel Relay Relay Relay Relay Names Names comA chA1 RL10 comC chC1 RL30 RL21...
Page 24
SECTION 4 - PROGRAMMING GUIDE pickering Table 4.1 - Module Sub-Unit Details: 40-610A-001 (Continued) 8 Bank, 16 Channel, 1 Pole Isolation Isolation Bank Chan. Channel Bank Chan. Channel Relay Relay Relay Relay Names Names comE chE1 RL50 comG chG1 RL70...
Page 25
SECTION 4 - PROGRAMMING GUIDE pickering Table 4.2 - Module Sub-Unit Details: 40-610A-002 4 Bank, 32 Channel, 1 Pole Isolation Isolation Bank Chan. Channel Bank Chan. Channel Relay Relay Relay Relay Names Names comA chA1 RL10 comB chB1 RL30 RL21...
SECTION 4 - PROGRAMMING GUIDE pickering PROGRAMMING THE MODULE Here are examples of using the drivers with the 40-610A-008 module. Other modules in the range operate in a similar way although may have additional sub-units. Using PILPXI To operate a relay the user could use the simple OpBit or the WriteSub commands OpBit DWORD sub_unit = 1;...
Page 52
SECTION 4 - PROGRAMMING GUIDE pickering THIS PAGE INTENTIONALLY BLANK VERY HIGH DENSITY MULTIPLEXER MODULE 40-610A Page 4.32...
Figure 5.2 - Pinouts: 4-Bank, 40-610-022-8/16/1 40-610-022-4/32/1 16-Channel, 1-Pole MUX Module 32-Channel, 1-Pole MUX Module 40-610A-001 40-610A-002 (200-pin Female LFH Connector (200-pin Female LFH Connector Viewed from Front of Module) Viewed from Front of Module) VERY HIGH DENSITY MULTIPLEXER MODULE 40-610A Page 5.1...
Page 54
Figure 5.4 - Pinouts: Single Bank, 40-610-022-2/64/1 40-610-022-1/128/1 64-Channel, 1-Pole MUX Module 128-Channel, 1-Pole MUX Module 40-610A-003 40-610A-004 (200-pin Female LFH Connector (200-pin Female LFH Connector Viewed from Front of Module) Viewed from Front of Module) VERY HIGH DENSITY MULTIPLEXER MODULE 40-610A Page 5.2...
Page 55
Figure 5.6 - Pinouts: 4-Bank, 40-610-022-4/16/2 40-610-022-8/8/2 8-Channel, 2-Pole MUX Module 16-Channel, 2-Pole MUX Module 40-610A-005 40-610A-006 (200-pin Female LFH Connector (200-pin Female LFH Connector Viewed from Front of Module) Viewed from Front of Module) VERY HIGH DENSITY MULTIPLEXER MODULE 40-610A Page 5.3...
Page 56
Figure 5.8 - Pinouts: Single Bank, 40-610-022-2/32/2 40-610-022-1/64/2 32-Channel, 2-Pole MUX Module 64-Channel, 2-Pole MUX Module 40-610A-007 40-610A-008 (200-pin Female LFH Connector (200-pin Female LFH Connector Viewed from Front of Module) Viewed from Front of Module) VERY HIGH DENSITY MULTIPLEXER MODULE 40-610A Page 5.4...
Page 57
Figure 5.10 - Pinouts: 4-Bank, 40-610-021-8/8/1 40-610-021-4/16/1 8-Channel, 1-Pole MUX Module 16-Channel, 1-Pole MUX Module 40-610A-009 40-610A-010 (200-pin Female LFH Connector (200-pin Female LFH Connector Viewed from Front of Module) Viewed from Front of Module) VERY HIGH DENSITY MULTIPLEXER MODULE 40-610A Page 5.5...
Page 58
Figure 5.11 - Pinouts: 2-Bank, 40-610-021-1/64/1 64-Channel, 1-Pole MUX Module 32-Channel, 1-Pole MUX Module 40-610A-012 40-610A-011 (200-pin Female LFH Connector (200-pin Female LFH Connector Viewed from Front of Module) Viewed from Front of Module) VERY HIGH DENSITY MULTIPLEXER MODULE 40-610A Page 5.6...
Page 59
Figure 5.14 - Pinouts: 4-Bank, 40-610-021-S-4/16/1 8-Channel, Screened 1-Pole MUX Module 16-Channel, Screened 1-Pole MUX Module 40-610A-013 40-610A-014 (200-pin Female LFH Connector (200-pin Female LFH Connector Viewed from Front of Module) Viewed from Front of Module) VERY HIGH DENSITY MULTIPLEXER MODULE 40-610A Page 5.7...
Page 60
40-610-021-S-2/32/1 40-610-021-S-1/64/1 32-Channel, Screened 1-Pole MUX Module 64-Channel, Screened 1-Pole MUX Module 40-610A-015 40-610A-016 (200-pin Female LFH Connector (200-pin Female LFH Connector Viewed from Front of Module) Viewed from Front of Module) VERY HIGH DENSITY MULTIPLEXER MODULE 40-610A Page 5.8...
Mises en garde au début du manuel. INSTALLATION PROBLEMS PROBLÈMES D’INSTALLATION The Plug & Play functionality of Pickering switch cards La fonctionnalité Plug & Play des cartes de generally ensures trouble-free installation. commutation Pickering assure généralement une installation sans problème.
OUTILS DE TEST DE SYSTEME DE SWITCHING SYSTEM TEST TOOLS COMMUTATION Please refer to Section 7 - Maintenance Information Référez-vous à la Section 7 - Information sur l’entretien VERY HIGH DENSITY MULTIPLEXER MODULE 40-610A REED RELAY MODULE 40-110/115/120/125 Page 6.2 Page 6.2...
Page 63
Pour les modules PXI qui sont pris en charge dans Pickering Interfaces’ Modular LXI Chassis (such l’un des châssis modulaire LXI de Pickering Interfaces as the 60-102B and 60-103B) no module software (comme le 60-102B et 60-103B) aucune mise à jour update is required.
Utilisateurs eBIRST, les outils de test de to locate faulty relays. système de commutation n’ont pas besoin d’utiliser cette fonction pour localiser les relais défectueux. HIGH DENSITY REED RELAY MODULES 40-140A/141/142/143 VERY HIGH DENSITY MULTIPLEXER MODULE 40-610A Page 7.2 Page 7.2...
Page 65
SECTION 7 - MAINTENANCE INFORMATION pickering Table 7.1 - Relay Look-Up Table: 40-610A-001 8 Bank, 16 Channel, 1 Pole Bank Channel Function Relay Bank Channel Function Relay RL21 RL22 RL23 RL24 RL25 RL26 RL27 RL28 2, 4, 6, 8, 10,...
Page 66
SECTION 7 - MAINTENANCE INFORMATION pickering Table 7.1 - Relay Look-Up Table: 40-610A-001 (Continued) 8 Bank, 16 Channel, 1 Pole Bank Channel Function Relay Bank Channel Function Relay RL41 RL61 RL42 RL62 RL43 RL63 RL44 RL64 RL45 RL65 RL46 RL66...
Page 67
SECTION 7 - MAINTENANCE INFORMATION pickering Table 7.2 - Relay Look-Up Table: 40-610A-002 4 Bank, 32 Channel, 1 Pole Bank Channel Function Relay Bank Channel Function Relay RL21 RL22 RL23 RL24 RL25 RL26 RL27 RL28 2, 4, 6, 8, 10,...
Page 68
SECTION 7 - MAINTENANCE INFORMATION pickering Table 7.2 - Relay Look-Up Table: 40-610A-002 (Continued) 4 Bank, 32 Channel, 1 Pole Bank Channel Function Relay Bank Channel Function Relay RL41 RL61 RL42 RL62 RL43 RL63 RL44 RL64 RL45 RL65 RL46 RL66...
Page 69
SECTION 7 - MAINTENANCE INFORMATION pickering Table 7.3 - Relay Look-Up Table: 40-610A-003 8 Bank, 16 Channel, 1 Pole Bank Channel Function Relay Bank Channel Function Relay RL21 RL22 RL23 RL24 RL25 RL26 RL27 RL28 2, 4, 6, 8, 10,...
Page 70
SECTION 7 - MAINTENANCE INFORMATION pickering Table 7.3 - Relay Look-Up Table: 40-610A-003 (Continued) 8 Bank, 16 Channel, 1 Pole Bank Channel Function Relay Bank Channel Function Relay RL41 RL61 RL42 RL62 RL43 RL63 RL44 RL64 RL45 RL65 RL46 RL66...
Page 71
SECTION 7 - MAINTENANCE INFORMATION pickering Table 7.4 - Relay Look-Up Table: 40-610A-004 1 Bank, 128 Channel, 1 Pole Bank Channel Function Relay Bank Channel Function Relay RL21 RL22 RL23 RL24 RL25 RL26 RL27 RL28 2, 4, 6, 8, 10,...
Page 72
SECTION 7 - MAINTENANCE INFORMATION pickering Table 7.4 - Relay Look-Up Table: 40-610A-004 (Continued) 1 Bank, 128 Channel, 1 Pole Bank Channel Function Relay Bank Channel Function Relay RL41 RL61 RL42 RL62 RL43 RL63 RL44 RL64 RL45 RL65 RL46 RL66...
Page 73
SECTION 7 - MAINTENANCE INFORMATION pickering Table 7.5 - Relay Look-Up Table: 40-610A-005 8 Bank, 8 Channel, 2 Pole Bank Channel Function Relay Bank Channel Function Relay RL21 RL22 RL23 RL24 RL25 RL26 RL27 RL28 1.2-8.2 Isolation 1.2-8.2 Isolation RL29 1.1-8.1...
Page 74
SECTION 7 - MAINTENANCE INFORMATION pickering Table 7.5 - Relay Look-Up Table: 40-610A-005 (Continued) 8 Bank, 8 Channel, 2 Pole Bank Channel Function Relay Bank Channel Function Relay RL41 RL61 RL42 RL62 RL43 RL63 RL44 RL64 RL45 RL65 RL46 RL66...
Page 75
SECTION 7 - MAINTENANCE INFORMATION pickering Table 7.6 - Relay Look-Up Table: 40-610A-006 4 Bank, 16 Channel, 2 Pole Bank Channel Function Relay Bank Channel Function Relay RL21 RL22 RL23 RL24 RL25 RL26 RL27 RL28 1.2-8.2 Isolation 1.2-8.2 Isolation RL29 1.1-8.1...
Page 76
SECTION 7 - MAINTENANCE INFORMATION pickering Table 7.6 - Relay Look-Up Table: 40-610A-006 (Continued) 4 Bank, 16 Channel, 2 Pole Bank Channel Function Relay Bank Channel Function Relay RL41 RL61 RL42 RL62 RL43 RL63 RL44 RL64 RL45 RL65 RL46 RL66...
Page 77
SECTION 7 - MAINTENANCE INFORMATION pickering Table 7.7 - Relay Look-Up Table: 40-610A-007 2 Bank, 32 Channel, 2 Pole Bank Channel Function Relay Bank Channel Function Relay 17.1 RL21 17.2 18.1 RL22 18.2 19.1 RL23 19.2 20.1 RL24 20.2 21.1 RL25 21.2...
Page 78
SECTION 7 - MAINTENANCE INFORMATION pickering Table 7.7 - Relay Look-Up Table: 40-610A-007 (Continued) 2 Bank, 32 Channel, 2 Pole Bank Channel Function Relay Bank Channel Function Relay 17.1 RL41 RL61 17.2 18.1 RL42 RL62 18.2 19.1 RL43 RL63 19.2 20.1...
Page 79
SECTION 7 - MAINTENANCE INFORMATION pickering Table 7.8 - Relay Look-Up Table: 40-610A-008 1 Bank, 64 Channel, 2 Pole Bank Channel Function Relay Bank Channel Function Relay 17.1 RL21 17.2 18.1 RL22 18.2 19.1 RL23 19.2 20.1 RL24 20.2 21.1 RL25 21.2...
Page 80
SECTION 7 - MAINTENANCE INFORMATION pickering Table 7.8 - Relay Look-Up Table: 40-610A-008 (Continued) 1 Bank, 64 Channel, 2 Pole Bank Channel Function Relay Bank Channel Function Relay 33.1 49.1 RL41 RL61 33.2 49.2 34.1 50.1 RL42 RL62 34.2 50.2 35.1...
Page 81
SECTION 7 - MAINTENANCE INFORMATION pickering Table 7.9 - Relay Look-Up Table: 40-610A-009 8 Bank, 8 Channel, 1 Pole Bank Channel Function Relay Bank Channel Function Relay RL41 RL42 RL43 RL44 RL45 RL46 RL47 RL48 Isolation Isolation RL49 — —...
Page 82
SECTION 7 - MAINTENANCE INFORMATION pickering Table 7.10 - Relay Look-Up Table: 40-610A-010 4 Bank, 16 Channel, 1 Pole Bank Channel Function Relay Bank Channel Function Relay RL41 RL42 RL43 RL44 RL45 RL46 RL47 RL48 Isolation Isolation RL49 — —...
Page 83
SECTION 7 - MAINTENANCE INFORMATION pickering Table 7.11 - Relay Look-Up Table: 40-610A-011 2 Bank, 32 Channel, 1 Pole Bank Channel Function Relay Bank Channel Function Relay RL41 RL42 RL43 RL44 RL45 RL46 RL47 RL48 Isolation Isolation RL49 — —...
Page 84
SECTION 7 - MAINTENANCE INFORMATION pickering Table 7.12 - Relay Look-Up Table: 40-610A-012 1 Bank, 64 Channel, 1 Pole Bank Channel Function Relay Bank Channel Function Relay RL41 RL42 RL43 RL44 RL45 RL46 RL47 RL48 Isolation 33-40 Isolation RL49 —...
Page 85
SECTION 7 - MAINTENANCE INFORMATION pickering Table 7.13 - Relay Look-Up Table: 40-610A-013 8 Bank, 8 Channel, 1 Pole - Screened Bank Channel Function Relay Bank Channel Function Relay RL21 RL22 RL23 RL24 RL25 RL26 RL27 RL28 Isolation Isolation RL29...
Page 86
SECTION 7 - MAINTENANCE INFORMATION pickering Table 7.13 - Relay Look-Up Table: 40-610A-013 (Continued) 8 Bank, 8 Channel, 1 Pole - Screened Bank Channel Function Relay Bank Channel Function Relay RL41 RL61 RL42 RL62 RL43 RL63 RL44 RL64 RL45 RL65...
Page 87
SECTION 7 - MAINTENANCE INFORMATION pickering Table 7.14 - Relay Look-Up Table: 40-610A-014 4 Bank, 16 Channel, 1 Pole - Screened Bank Channel Function Relay Bank Channel Function Relay RL21 RL22 RL23 RL24 RL25 RL26 RL27 RL28 Isolation Isolation RL29...
Page 88
SECTION 7 - MAINTENANCE INFORMATION pickering Table 7.14 - Relay Look-Up Table: 40-610A-014 (Continued) 4 Bank, 16 Channel, 1 Pole - Screened Bank Channel Function Relay Bank Channel Function Relay RL41 RL61 RL42 RL62 RL43 RL63 RL44 RL64 RL45 RL65...
Page 89
SECTION 7 - MAINTENANCE INFORMATION pickering Table 7.15 - Relay Look-Up Table: 40-610A-015 2 Bank, 32 Channel, 1 Pole Bank Channel Function Relay Bank Channel Function Relay RL21 RL22 RL23 RL24 RL25 RL26 RL27 RL28 Isolation 17-24 Isolation RL29 Link...
Page 90
SECTION 7 - MAINTENANCE INFORMATION pickering Table 7.15 - Relay Look-Up Table: 40-610A-015 (Continued) 2 Bank, 32 Channel, 1 Pole Bank Channel Function Relay Bank Channel Function Relay RL41 RL61 RL42 RL62 RL43 RL63 RL44 RL64 RL45 RL65 RL46 RL66...
Page 91
SECTION 7 - MAINTENANCE INFORMATION pickering Table 7.16 - Relay Look-Up Table: 40-610A-016 1 Bank, 64 Channel, 1 Pole - Screened Bank Channel Function Relay Bank Channel Function Relay RL21 RL22 RL23 RL24 RL25 RL26 RL27 RL28 Isolation 17-24 Isolation...
Page 92
SECTION 7 - MAINTENANCE INFORMATION pickering Table 7.16 - Relay Look-Up Table: 40-610A-016 (Continued) 1 Bank, 64 Channel, 1 Pole - Screened Bank Channel Function Relay Bank Channel Function Relay RL41 RL61 RL42 RL62 RL43 RL63 RL44 RL64 RL45 RL65...
Need help?
Do you have a question about the 40-610A and is the answer not in the manual?
Questions and answers