Ruck Ventilatoren RS 100L 20 Installation, Operating And Maintenance Instruction

Ruck Ventilatoren RS 100L 20 Installation, Operating And Maintenance Instruction

Tube fan for ventilation applications
Hide thumbs Also See for RS 100L 20:

Advertisement

Installation, operating and maintenance instructions
English
RS
Example configuration shown
CONTENTS
FOREWORD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
1.
IMPORTANT INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
2.
GENERAL SAFETY INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
3.
ADHERE TO THE FOLLOWING INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
4.
PRODUCT INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
5.
DELIVERY CONTENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
6.
TECHNICAL DATA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
7.
DIMENSIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
8.
TRANSPORT AND STORAGE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
9.
ASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
10.
ELECTRICAL CONNECTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
11.
COMMISSIONING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
12.
MAINTENANCE AND CLEANING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
13.
LIFETIME AND DISPOSAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
14.
TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
15.
ruck Ventilatoren GmbH
Max-Planck-Str. 5
D-97944 Boxberg-Windischbuch
Tel.
+49 7930 9211-300
Fax
+49 7930 9211-166
info@ruck.eu
www.ruck.eu
Tube fan for ventilation
applications
The original instructions were created in the German
Made in EU
2018
language.
Information updated
print 21.09.2021
Subject to change

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RS 100L 20 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Ruck Ventilatoren RS 100L 20

  • Page 1: Table Of Contents

    TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 ruck Ventilatoren GmbH Max-Planck-Str.
  • Page 2: Foreword

    FOREWORD Dear customers, Thank you for choosing our device. Before operating the unit, please read carefully these installation, operating and maintenance instructions. If you have any questions, please contact: (Contact details see page 1) The data provided in these installation, operating and maintenance instructions are for the product description only. A statement about a certain condition or a suitability for a certain application cannot be derived from our information.
  • Page 3: General Safety Instructions

    2.2. Provisions and regulations When properly installed and operated, the device complies with the applicable standards and EU Directive at the time of its placing on the market. In addition, observe generally valid, legal and other binding regulations of the European or national legislation as well as the regulations in your country for accident prevention and environmental protection.
  • Page 4 3.1. Intended use Our devices are incomplete machineries as defined in the EU Machinery Directive 2006/42/EC (partly completed ma- chinery). The product is a not ready-for-use machine in terms of the machine directive. It is intended exclusively for installation in a machine or in ventilation equipment and installations or for combination with other components to form a machinery or installation.
  • Page 5 Safety sign (warning Consequence triangle) General warning! Indicates possible hazardous situations. Failure to observe the warnings may result in perso- nal injury and / or damage to property. Electricity warning (hazardous voltage)! Indicates possible hazards due to electricity. Failure to observe the warnings may result in death, injury and/or damage to property.
  • Page 6: Adhere To The Following Instructions

    ADHERE TO THE FOLLOWING INSTRUCTIONS 4.1. General instructions ■ Persons who assemble, operate, disassemble or maintain our devices must not be under the influence of alcohol, drugs or pharmaceuticals that may affect perception and responsiveness. ■ Responsibilities for the operation, maintenance and regulation of the product should be clearly determined and observed so that there can be no unclear areas of responsibility with regard to safety.
  • Page 7: Delivery Contents

    ■ 1 x Installation, operating and maintenance instructions ■ EC Declarations of conformity ■ EC-Declaration of Incorporation (Directive 2006/42/EC) TECHNICAL DATA Product name °C °C dB(A) dB(A) RS 100L 20 143351 230V ~ 50/60 IPX4 116403 RS 125L 20 143353 230V ~...
  • Page 8: Dimensions

    116471 RS 315L * 130637 230V ~ IPX4 116471 * only available outside the EU DIMENSIONS Product name Item number Ø99 Ø245 RS 100L 20 143351 Ø124 Ø245 RS 125L 20 143353 Ø149 Ø270 RS 150 10 134984 Ø159 Ø270...
  • Page 9: Transport And Storage

    TRANSPORT AND STORAGE Transport and storage should only be performed by specialist personnel in accordance with the assembly and opera- ting manual and regulations in force. The following points should be noted and followed: ■ Check the delivery according to the delivery note to ensure it is complete and correct and check for any damage. Any missing quantities or damage incurred during transport should be confirmed by the carrier.
  • Page 10: Electrical Connection

    10.1. Assembly with accessories Protection grille Filter box with mat filter Fast clamps Tube silencer rigid Tube silencer flexible GS 01 Device switch Mounting bracket Back draught shutter RSK-D Back draught shutter with seal Filter box for bag filter and heating Filter box for bag filter 11.
  • Page 11 ■ The electrical connections must be made as shown in the corresponding wiring diagrams and terminal diagrams. ■ The type of cable, size of cable and method of laying should be determined by an authorized electrician. ■ Low and extra-low voltage cables should be laid separately. ■...
  • Page 12: Commissioning

    12. COMMISSIONING Commissioning by trained technical personnel may only be performed after any risk has been ruled out. The following checks should be performed in accordance with the installation and operating manual and the regu- lations in force: ■ Correctly sealed installation of the unit and duct system. ■...
  • Page 13: Lifetime And Disposal

    13.1. Checklist Maintenance and Service Description check interval Triggering device monthly ■ Fan Check fan for function and operational readiness (test run at least 15 minutes) every 6 months Check fan for function and operational readiness (test run at least 1 hour) yearly Check for dirt, damage, corrosion and fastening every 6 months...
  • Page 14: Troubleshooting

    15. TROUBLESHOOTING Fault Possible cause Remedy methods ■ Fan does not start ■ No power supply ■ Check mains supply / connections ■ Impeller does not rotate freely ■ Find out the causes and, if possible, remove the fault. If not possible, contact the sup- plier.