Higher
Operation
Mode
(+2°C)
Cooling
27°C
Soft Dry
24°C
Heating
23°C
8.5. Sleep Mode Auto Operation
Cooling or Soft Dry Operation
When you press the SLEEP Mode, the following movement will start to avoid overcooling.
- The fan speed refer to Indoor Fan Motor Control.
- The setting temperature will be risen by 0.5°C at the start of
operation and by 0.5°C one hour later.
- The operation will stop after 8 hours.
- When using together with the Timer, the ON-Timer has priority.
Heating Operation
When you press the SLEEP Mode, the following movement will start to avoid overheating.
- The fan speed refer to Indoor Fan Motor Control.
- The setting temperature will be risen by 2°C at the start of operation
and by 3°C one hour later.
- The operation will stop after 8 hours.
- When using together with the Timer, the ON-Timer has priority.
Standard
Lower
(±0°C)
(-2°C)
25°C
23°C
22°C
20°C
21°C
19°C