J. DIP Switch Programming/Speaker and Microphone Adjustments
Two POTs are provided to increase or decrease speaker volume and microphone sensitivity. In certain noisy locations
the microphone sensitivity may need to be decreased as shown below.
may cause distorted audio, prevent the distant party from breaking over and inhibit second number redialing.
Switch
Switch
Description
2
1
ON
ON
Normal audio detection
OFF
Increase audio detect sensitivity for low level lines. Useful
OFF
in applications in which voice or busy signals have trouble
breaking over the speaker.
DIP
Position
Description
Switch
1
ON
"HELP" / "CALL" button alternately connects
and disconnects calls (factory default)
1
OFF
"HELP" / "CALL" button connects calls only
2
ON
Incoming calls answered (factory setting)
2
OFF
Incoming calls are not answered
3
ON
Normal operation mode (factory setting)
3
OFF
Learn mode - Any incoming calls are automatically entered
into the programming mode (no security code required).
Use this option if you have forgotten your security code.
K. Central Station Programming
The standard 1600A emergency phone is capable of communicating using the "Ademco Contact I.D.", "Ademco High
Speed", "DTMF 4+1 Express", or the "DTMF 4+2 Express" formats. All formats use the programming memory location
#20 to store the account code and alarm details.
1. Central Station Programming Features
a. Accessing the Programming Mode
Before programming, you must access the programming mode (see Programming section A).
b. Enabling/Disabling Central Station Mode
The 1600A Series emergency phone can be placed in the "Central Station Mode" by entering a central station
phone number in position #05 while programming. To cancel the "Central Station Mode," clear position #05 by
entering #05 only (see Programming section D).
To Program the 1600A Series Phone...
...to enable central station programming and dial 952-2567
...to disable central station programming
c. Ring No Answer
When the 1600A Series emergency phone is in the "Central Station Mode", it is best to have the ring no answer
set to a minimum of three, because some receivers send a long tone after answering the line that sounds like
a ring back. If the 1600A is set to a ring no answer of two, the phone will disconnect (see Programming
section F).
Setting the microphone gain too high
Microphone
Sensitivity
ON
OFF
1 2
ON
OFF
1 2 3
Step 2 - Enter Digits:
Step 1:
Enter Programming
Enter Programming
Speaker
Volume
9 5 2 2 5 6 7 # 0 5
# 0 5
9