Available languages

Technical data

To upgrade from luminaries equipped with QT / HS_ /HI_ to
LED. HS_, HI_ 50W / 70W / 100W
QT-DE: 120W / 200W /
Ledikit Streetlight LA -2x2 / -3x2/ -4x2
Nominal voltage
Nominal current
Nominal power
Power factor
Protection rating
Nominal voltage of LED
Light distribution
Luminous fl ux [klm]
Light colour / CCT
Colour rendering index
(CRI)
Dimensions LxWxH
Weight
Ambient temperature
Ingress protection (upon
installation)
Conformity
Service life [h]
Special equipment
TempSafe (TS)
overtemperature protection
Constant Flux (CF)
constant luminous fl ux over 50,000 hr
AutomaticDimControl (ADC)
Scope of
LM
LED module with connecting cable with 4-pole plug
TB
Support bracket for mounting in the luminaire housing
BG
LED operating device carrier with 4-pole plug-in coupling
Six M4x8 screws (TORX, self-tapping), tooth lock washers
2
220-240V AC 50Hz
0,3 / 0,3 / 0,4
26..32 / 36..42 / 48..54
>0,9
II
<120V, SELV
diverse
3,0 / 4,4 / 6,4
WW(3.000K) / NW(4.000K)
>80
LM: 280 x 160 x 20mm³
BG: 170 x 85 x 45mm³
1,4kg
-35...+35°C
IP20
CE
>60.000
Setting AutomaticDimControl (ADC)
The Ledikit is equipped with an OSRAM
Optotronic4DIM or Philips XITANIUM LED operating
device suitable for your project. Parameters for the
dimming functionality and dimming profile are set in
the factory, by means of software programming, as
requested by the customer.
In order to set parameters for the ASTRODIM func-
tion (automatic dimming, based on midnight),
the T_dim_on and T_dim_off values desired for the
system and the desired level of dimming (50% is
standard) should be communicated with the order.
The values set in the factory are shown on a sticker
located next to the type plate. A change is possible
with a specific programming adapter and a PC with
corresponding programming software.
Using the PSt input, the Ledikit can be added to an
existing control phase. If this is done, the existing
control logic is detected automatically once switched
on for around 20min.
100%
dim
Level
T
T
dim
dim
ein
aus