Liquid soap and disinfectant sensor dispenser

Advertisement

Quick Links

D P1 1 0 2E / DP110 2E- SAN
DOLPHIN LIQUID SOAP AND DISINFECTANT
SENSOR DISPENSER
USER GUI D E F O R M AIN TENAN CE AND CARE
TECHNIC AL HELPLINE
01424
DOLPHINSOLUTIONS.CO.UK
202224

Advertisement

loading
Need help?

Need help?

Do you have a question about the DP1102E and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Dolphin DP1102E

  • Page 1 D P1 1 0 2E / DP110 2E- SAN DOLPHIN LIQUID SOAP AND DISINFECTANT SENSOR DISPENSER USER GUI D E F O R M AIN TENAN CE AND CARE TECHNIC AL HELPLINE 01424 202224 DOLPHINSOLUTIONS.CO.UK...
  • Page 2: Table Of Contents

    CON TE NTS Open and close housing Refill tank Replace disp. bottle Change batteries Change pump Change eModule Check function Contact us...
  • Page 3 SA FE T Y I N FOR MATI ON Operating fluids and cleaning agents can cause skin and eye irritation or damage. ► Always wear protective gloves. ► Keep operating fluids and cleaning agents out of eyes. ► Observe the safety information on the packaging of the operating fluids and cleaning agents. Troubleshooting The dispenser only works when installed and, if applicable, when the housing is closed (surface-mounted dispensers).
  • Page 4 Fault/LED signal Cause Solution Dispenser triggers sporadi- Interference due to mains ► Switch to battery operation cally without actuation supply line or static charge ► Check interference in the power grid and rectify if necessary Dispenser triggers continu- Sensor dirty ►...
  • Page 5 Cleaning instructions for stainless steel surfaces: Soiling Recommended cleaning Recommended cleaning agent utensil Fingerprints, dust – Washing-up liquid solution – Damp cloth or leather – Commercially available – Dry cloth for buffing stainless steel or vinegar-based cleaning agent – Glass cleaner Soap residues inside –...
  • Page 6: Open And Close Housing

    OP E N A N D CL OS E HOUSIN G For surface and flush mounted dispensers only. ► Open: Unlock the lock with the key and carefully open the housing. ► Close: Close housing as far as it will go, lock it and remove the key.
  • Page 7: Replace Disp. Bottle

    RE P L A C E DI S P. BO TT LE The disposable bottle is not intended for refilling. ► Open housing and check filling level. ► Bottle is empty Pull out empty bottle straight upwards. ► Residual liquid in the bottle: Pull out bottle and pump together upwards, hold them horizontally over a sink and pull bottle carefully off the...
  • Page 8: Ch A N G E Ba T Ter Ies

    CH A N G E BA T TER IES ► Do not use rechargeable batteries. ► Observe the notes on the disposal of batteries on page 10 (or your language). 1. Open battery compartment cover on the right hand side of the Module and remove batteries.
  • Page 9: Change Pump

    C H AN GE PUMP ► To avoid spilling residual soap in the dispenser: Pull out the pump and, if applicable, the bottle/plug-in tank together upwards. ► Hold the pump and the bottle/plug-in tank horizontally over a sink and remove the bottle from the pump.
  • Page 10: Change Emodule

    C H A N G E M O D U L E 2. + 3. 1. Pull out the pump together with the tank or disposable bottle upwards. 2. Press securing tab (B) to unlock Module and pull it out upwards. 3.
  • Page 11: Check Function

    CHECK FUNCTION With surface-mounted devices, the dispenser only works when the housing is completely closed. ► Hold your hand under the dispenser so that the Module triggers the pump. After changing the pump, several actuations may be required until liquid is dispensed.
  • Page 12: Contact Us

    CON TACT US Dolphin Southpoint, Compass Park Junction Road, Bodiam TN32 5BS United Kingdom +44 (0)1424 202 224 info@dolphinsolutions.co.uk dolphinsolutions.co.uk © Dolphin Solutions Ltd.