Installation Guide
Figure 6-128 Installing monitoring signal cables in a scenario of two APM30Hs+four
IBBS200D/IBBS200T+one TMC
Step 6 Route the cable by referring to
cable.
Step 7 Label the installed cables. For details, see Attaching an L-Shaped Label.
Step 8 Run each cable that leaves the cabinet in the PVC corrugated pipe, and then tie the pipe to the
cable hole in the cabinet.
----End

6.5.6 Installing a CPRI Optical Cable

A CPRI optical cable transmits CPRI signals between a BBU and an RRU.
Context
l
l
l
Issue 06 (2011-09-15)
The single-mode optical module is labeled "SM" and multi-mode optical module is labeled
"MM".
If the puller of an optical module is blue, the module is a single-mode optical module. If
the puller of an optical module is black or grey, the module is a multi-mode optical module.
The optical module to be installed must have a matching rate with the corresponding CPRI
port.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
6 Outdoor Scenario with AC Power Supply (BBU Installed
6.5.1 Cabling
Requirements, and then use cable ties to bind the
in an APM30H)
131