hager New VegaD Technical Manual
Hide thumbs Also See for New VegaD:
Table of Contents

Advertisement

Quick Links

Technical Manual
New VegaD
for surface-mounting
flush-mounting
& Accessories

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the New VegaD and is the answer not in the manual?

Questions and answers

Summary of Contents for hager New VegaD

  • Page 1 Technical Manual New VegaD for surface-mounting flush-mounting & Accessories...
  • Page 2: Table Of Contents

    Table of contents About this manual Subject of the manual Warranty and Liability For your safety Proper use Requirements for authorised personnel Product range by New VegaD surface External dimensions Market-specific product ranges 3.2.1 ACN Version 3.2.2 AN Version 3.2.3 BMN Version 3.2.4...
  • Page 3 Table of contents Single and spare parts 6.3.1 FD00A… = Standard Accessories 6.3.2 FD00B… = Side Brackets for vertical cables 6.3.3 FD00C… = Covers 6.3.4 FD00M… = Mounting plates 6.3.5 FD00G… = Gallery Adapter for VegaD surface versions (FD…) 6.3.6 FD00F…...
  • Page 4: About This Manual

    1 About this manual These instructions are an integral part of the New VegaD enclosures. Chapter index Subject of the manual Warranty and Liability Technical changes reserved...
  • Page 5: Subject Of The Manual

    Warranty and Liability These instructions do not extend the Sales and Delivery Conditions of Hager. No new claims concerning the warranty or guarantee, which extend beyond the Sales and Delivery Conditions, can be derived from this instruction manual.
  • Page 6: For Your Safety

    2 For your safety Avoid dangers. Adherence to the safety information in this section is a prerequisite for the safe assembly and use of the distribution board. Also observe the safety information provided in other sections. Chapter index Proper use Requirements for authorised personnel Technical changes reserved...
  • Page 7: Proper Use

    IP30/40/41, for residential and commercial buildings with a maximum supply current of 160 A. New VegaD flush enclosures are installed at a depth of 110 mm in the wall. They are available in 6 different heights and 2 different depths.
  • Page 8: Requirements For Authorised Personnel

    For your safety Limitation of operating areas There are certain areas in which the New VegaD enclosure may not be used, in order to prevent hazards or damage to the enclosure. The New VegaD is not suitable for use: in areas that require a higher protection type,...
  • Page 9: Product Range By New Vegad Surface

    3 Product range by New VegaD surface Chapter index External dimensions Market-specific product ranges Technical changes reserved...
  • Page 10: External Dimensions

    Product range by New VegaD surface External dimensions FDX2 ACN / BN / CN / DN / LN / RN / ZN full equipped Between uprights FDX2 AN / MN partly equipped Between uprights FDX2 BMN partly equipped, Multimedia Between uprights...
  • Page 11 Product range by New VegaD surface FDX2GN empty Between uprights FDX2ZN tarif bleu triphasé French Platine Michaud 330 x 330 mm Technical changes reserved...
  • Page 12: Market-Specific Product Ranges

    Product range by New VegaD surface Market-specific product ranges 3.2.1 ACN Version full equipped with transparent door door mounted-in with Quick-Connect terminals Green/Yellow Multi- Instruction 4 screws kit PEN QC Quick- functional sheet with 4x16 for Plaster DIN A4 label...
  • Page 13: An Version

    Product range by New VegaD surface 3.2.2 AN Version partly equipped without door two first rows to complete with Quick-Connect terminals Green/Yellow 4 screws Multi- kit 4x16 5 caps kit Paper Instruction PEN QC functional cover Quick- sheet with Cover...
  • Page 14: Bmn Version

    Product range by New VegaD surface 3.2.3 BMN Version full equipped with plain door door mounted-in, door opening angle 135° with Quick-Connect terminal Green/Yellow 4 screws Multi- kit 4x16 5 caps kit Paper Instruction PEN QC functional cover Quick- DIN rails...
  • Page 15 Product range by New VegaD surface Parts delivered-by in each BMN enclosure FD00P5 FZ794 VZ00ASF Example of installation Example: standard enclosure FD42CN (left) associated with multimedia enclosure FD42BMN (right) Technical changes reserved...
  • Page 16: Bn Version

    Product range by New VegaD surface 3.2.4 BN Version full equipped with plain door door mounted-in, door opening angle 135° with Quick-Connect terminals Green/Yellow 4 screws Multi- kit 4x16 5 caps kit Paper Instruction PEN QC functional cover Quick- sheet with...
  • Page 17: Cn Version

    Product range by New VegaD surface 3.2.5 CN Version full equipped with transparent door door mounted-in, door opening angle 135° with Quick-Connect terminals Green/Yellow 4 screws Multi- kit 4x16 5 caps kit Paper Instruction PEN QC functional cover Quick- sheet with...
  • Page 18: Dn Version

    Product range by New VegaD surface 3.2.6 DN Version full equipped without door with Quick-Connect terminals Green/Yellow 4 screws Multi- kit 4x16 5 caps kit Paper Instruction PEN QC functional cover Quick- sheet with Cover Cable Equipment holder 24 side...
  • Page 19: Gn Version

    Product range by New VegaD surface 3.2.7 GN Version empty without door without Quick-Connect terminals Instruction sheet 4 screws kit 4x16 for 5 caps kit for Equipment PEN QC holder 24 with Quick-Connect optional PEN holder or covering wall-fixation delivered-by...
  • Page 20: Ln Version

    Product range by New VegaD surface 3.2.8 LN Version full equipped without door without Quick-Connect terminals Instruction 4 screws kit Multi- Paper cover PEN QC holder sheet w /o 4x16 for 5 caps kit for Equipment functional side Cover slot strip...
  • Page 21: Mn Version

    Product range by New VegaD surface 3.2.9 MN Version partly-equipped without door two first rows to complete with Quick-Connect terminals Green/Yellow & Blue Instruction 4 screws kit Paper cover PEN QC Multi- 5 caps kit Quick- sheet with 4x16 for...
  • Page 22: Rn Version

    Product range by New VegaD surface 3.2.10 RN Version full equipped without door with Quick-Connect terminals Green/Yellow & Blue Multi- Instruction 4 screws kit 5 caps kit for Paper cover PEN QC Quick- functional sheet with 4x16 for covering marking...
  • Page 23: Zn Version

    Product range by New VegaD surface 3.2.11 ZN Version equipped with French platine kit Tarif bleu triphasé without door Instruction sheet with 4 screws kit 4x16 for Paper cover marking Equipment Kit Michaud Platine 5 caps kit for covering Quick-Connect optional PEN holder strips 24 mod.
  • Page 24: Product Range By New Vegad Flush

    4 Product range by New VegaD flush Chapter index External dimensions Market-specific product ranges Technical changes reserved...
  • Page 25: External Dimensions

    Product range by New VegaD flush External dimensions FUX2 ACN / BN / CN / DN / LN / RN full equipped Between uprights FUX2 AN / MN partly equipped Between uprights FUX2GN empty Between uprights Technical changes reserved...
  • Page 26: Market-Specific Product Ranges

    Product range by New VegaD flush Market-specific product ranges 4.2.1 ACN Version full equipped with transparent door door mounted-in with Quick-Connect terminals Green/Yellow Instruction 4 screws kit PEN QC Quick- Side cable sheet with 4x16 for Plaster DIN A4 label...
  • Page 27: An Version

    Product range by New VegaD flush 4.2.2 AN Version partly equipped without door two first rows to complete with Quick-Connect terminals Green/Yellow flush high-depth version 4 screws kit 4x16 Paper Instruction PEN QC cover Quick- Side cable sheet with Cover slot...
  • Page 28: Bn Version

    Product range by New VegaD flush 4.2.3 BN Version full equipped with plain door door mounted-in with Quick-Connect terminals Green/Yellow 4 screws kit 4x16 Paper Instruction PEN QC cover Quick- Side cable sheet with Cover slot Plaster Equipment holder 24...
  • Page 29: Cn Version

    Product range by New VegaD flush 4.2.4 CN Version full equipped with transparent door door mounted-in with Quick-Connect terminals Green/Yellow 4 screws kit 4x16 Paper Instruction PEN QC cover Quick- Side cable sheet with Cover slot Plaster Equipment holder 24...
  • Page 30: Dn Version

    Product range by New VegaD flush 4.2.5 DN Version full equipped without door with Quick-Connect terminals Green/Yellow Instruction 4 screws kit Paper cover PEN QC Quick- Side cable sheet with 4x16 for Plaster marking Equipment holder 24 Cover slot Connect...
  • Page 31: Gn Version

    Product range by New VegaD flush 4.2.6 GN Version empty without door without Quick-Connect terminals flush high-depth version 4 screws kit 4x16 for PEN QC holder 24 Instruction sheet with Plaster cardboard Equipment standard optional PEN holder or modules wide...
  • Page 32: Ln Version

    Product range by New VegaD flush 4.2.7 LN Version full equipped without door without Quick-Connect terminals 4 screws kit Paper cover PEN QC Instruction sheet Side cable 4x16 for Plaster marking Equipment holder 24 Cover slot bracket for optional PEN...
  • Page 33: Mn Version

    Product range by New VegaD flush 4.2.8 MN Version partly-equipped without door two first rows to complete with Quick-Connect terminals Green/Yellow & Blue flush high-depth version Instruction 4 screws kit Paper cover PEN QC Quick- Side cable sheet with 4x16 for...
  • Page 34: Rn Version

    Product range by New VegaD flush 4.2.9 RN Version full-equipped without door with Quick-Connect terminals Green/Yellow & Blue Instruction 4 screws kit Paper cover PEN QC Quick- Side cable sheet with 4x16 for Plaster marking Equipment holder 24 Cover slot...
  • Page 35: Doors For Flush And Surface Enclosures

    5 Doors for flush and surface enclosures Chapter index External dimensions Door mounting into enclosure frames Door hinges Technical changes reserved...
  • Page 36: External Dimensions

    Doors for flush and surface enclosures External dimensions PN Version - plain door Door material Full steel door 1.2 mm thick FD22PN FD32PN FD42PN FD52PN FD62PN FD72PN TN Version - transparent door Door material Tempered 3 mm glass FD22TN FD32TN FD42TN FD52TN FD62TN...
  • Page 37 Doors for flush and surface enclosures Standard closing system can be sealed with max Ø 1,5 mm wire Standard closing system is available as spare part with reference FD00S0 Technical changes reserved...
  • Page 38: Door Mounting Into Enclosure Frames

    Doors for flush and surface enclosures Door mounting into enclosure frames In New VegaD flush enclosures, customer doesn't have to punch out metal openings for door closing latch, as they are already punched. Also in New VegaD surface enclosures, customer doesn't have to punch out plastic openings for door closing latch, as they are already extruded.
  • Page 39: Door Hinges

    Doors for flush and surface enclosures Door hinges Each door is composed of 1 fix hinge and 1 removable one. Both hinge positions can be adjusted up to ~2 mm by hand by turning small wheel (arrow), so that door fits perfectly into frame. Hinges have a small gasket on metal pin, to pre- vent water to enter into enclosure and thus pre- serve IPx1.
  • Page 40: Accessories

    6 Accessories Chapter index Naming rules Equipment units Single and spare parts Technical changes reserved...
  • Page 41: Naming Rules

    Accessories Naming rules Equipment units, accessories and spare parts for New VegaD system have been named according these rules: first 2 letters: always FD first number: 0 for equipment units, accessories and spare parts (New VegaD system only) second number:...
  • Page 42: Equipment Units

    Accessories Equipment units Equipment units are compatible with surface and flush high-depth versions. Equipment units are not compatible with flush low-depth versions. 6.2.1 FD01.. = Equipment units, height 150 mm FD01A1: Kit for 1 distribution DIN rail (430 x 150 x 147 mm) with 1x label holder+paperstrip 24 modules, 4 mounting screws and 2 cable brackets for surface delivered-by with 150 mm slotted cover 24 modules.
  • Page 43 Accessories FD01K1: Kit for 160 A MCCB horizontal 3 and 4 poles (430 x 150 x 147 mm) with 1x label holder+paperstrip 24 mod., 1 blanking strip 1,5 module (27 mm) and 4 mounting screws delivered-by MCCB H3 or H3+ 3 or 4 poles 160 A to screw-in horizontally label holder &...
  • Page 44 Accessories MCCB fixing on metal plate with M4 screws deliv- ered-by Technical changes reserved...
  • Page 45: Fd02

    Accessories 6.2.2 FD02.. = Equipment units, height 300 mm FD02A1: Kit with 2 distribution DIN rails (430 x 300 x 147 mm) with 2x label holder+paperstrip 24 mod., 4 mounting screws and 4 cable brackets surface delivered-by. - with 300 mm 2x slotted cover 24 mod. FD02A2: Kit with 2 depth-adjustable DIN rails (430 x 300 x 147 mm) with 8 mounting screws and 4 DIN rail insulating parts delivered-by with 300 mm plain cover...
  • Page 46 Accessories FD02A3: Kit with 1 depth-adjustable DIN rail and 1 standard DIN rail (430 x 300 x 147 mm) with 1x label holder+paperstrip 24 mod., 2 cable brackets surface, 8 mounting screws and 2 DIN rail insulating parts delivered-by with 300 mm 1x slotted cover 24 mod. FD02C2: Kit with depth-adjustable perforated plate (430 x 300 x 147 mm) with 4 DIN rail insulating parts and 12 mounting screws delivered-by with Ø...
  • Page 47 Accessories FD02F1: Kit with french DB plate (for Disjoncteur de Branchement) (430 x 300 x 147 mm) with 2x label holder+paperstrip 7 mod. premounted, 4 premounted screws delivered-by with removable 7 mod. DIN rail insulation parts with 250 x 250 x 40 mm French Gamma platine premounted FD02F2: Kit with french DB + linky meter plate (430 x 300 x 147 mm) with 2x label holder+paperstrip 7 mod.
  • Page 48 Accessories FD02K1: Kit for 160 A MCCB vertical 3 and 4 poles (430 x 300 x 147 mm) with 1x label holder+paperstrip 24 mod., 1 plastic elevation part for modular devices, 1 blanking strip 12 mod., 2 cable brackets surface and 4 mounting screws delivered-by MCCB H3 3 or 4 poles 160 A to snap-in on DIN rail (MCCB not included) Kit also compatible with MCCB H3+ P160 3 or 4 poles...
  • Page 49 Accessories Technical changes reserved...
  • Page 50 1x label holder+paperstrip 24 mod., 1 blanking strip 24 mod., 1 positioning aid metallic bar and 4 mounting screws delivered-by Kit can be mounted in New VegaD surface FDxxxN and flush high-depth FUxxAN -GN -MN enclosures for mounting modular switches HIC4..A until 160 A.
  • Page 51: Fd03

    Accessories 6.2.3 FD03.. = Equipment units, height 450 mm FD03A1: Kit with 3 distribution DIN rails (430 x 450 x 147 mm) with 3x label holder+paperstrip 24 mod., 12 mounting screws and 6 cable brackets surface delivered-by with 3x 150 mm slotted cover 24 mod. FD03Z1: Kit for meter + main switch three-phase (430 x 450 x 147 mm) with French platine kit Tarif bleu triphasé...
  • Page 52: Single And Spare Parts

    Accessories Single and spare parts 6.3.1 FD00A… = Standard Accessories FD00A1: 10x label holder+paperstrip 24 mod. all 24 mod. slotted covers in enclosures and equipment kits are already delivered with 1x label holder+paperstrip 24 mod. to snap-in Reference to use as spare part or to double labels on a row (top and bottom, for example for Tebis with 2 outputs) paper length 428 mm 1-sided printed, other side blank...
  • Page 53 Accessories FD00A3: horizontal partition plate (surface only) 24 mod. FD00A4: horizontal partition plate (flush high-depth only) 24 mod. FD00A5: horizontal partition plate (flush low-depth only) 24 mod. Partition IP2X to mount in 3 different positions: Pos. 1: direct on uprights (no cut-out, direct use) Pos.
  • Page 54 Accessories See mounting instruction below: Technical changes reserved...
  • Page 55 Accessories Technical changes reserved...
  • Page 56: Fd00B

    Accessories 6.3.2 FD00B… = Side Brackets for vertical cables FD00B1: 10x side Brackets for vertical cables for surface versions all equipped surface enclosures and kits with 24 mod. DIN rails are already delivered with 2 brackets per DIN rail Reference to use as spare part or to complete first two-rows in AN or MN versions or to equip GN versions USP: Part can be used in 3 different positions through cut-outs at 2 different points (see arrows):...
  • Page 57 Accessories Pos. 1: Part can be snapped-in into 3 different depths (20 mm raster) and loosen though finger pressure under orange DIN rail holder. Pos. 2: Part can be snapped-in into 3 different depths (20 mm raster) and loosen though finger pressure under orange DIN rail holder.
  • Page 58 Accessories FD00B2: 10x side Brackets for vertical cables for flush versions all flush enclosures are already delivered with 2 brackets per DIN rail Reference to use as spare part or to complete first two-rows in AN or MN versions or to equip GN versions Part can be snapped-in into 1 single position and loosen: through pressure from top with screwdriver on plastic lever (flush low depth) through finger pressure under orange DIN rail holder (flush high depth)
  • Page 59: Fd00C

    Accessories 6.3.3 FD00C… = Covers Covers can be mounted on all surface and flush enclosures FD00C1: 300 mm 2x slotted cover 24 mod. with 2x label holder+paperstrip 24 mod. delivered-by FD00C2: 300 mm plain cover 24 mod. Plain area in the middle: 430 x 268 mm 2 slots top/bottom enable fixing of marking strips FD00A1 Technical changes reserved...
  • Page 60 Accessories FD00C3: 300 mm 1x slotted cover 24 mod. with 1x label holder+paperstrip 24 mod. delivered-by 2 slots top/bottom enable fixing of marking strips FD00A1 FD00C4: 150 mm 1x slotted cover 24 mod. with 1x label holder+paperstrip 24 mod. delivered-by 2 slots top/bottom enable fixing of marking strips FD00A1 FD00C5: 150 mm plain cover 24 mod.
  • Page 61: Fd00M

    Accessories 6.3.4 FD00M… = Mounting plates Mounting plates can be screwed on all surface and flush enclosures, directly on vertical uprights. FD00M1: 215 mm Ø 3,2 perforated plate (434 x 215 x 1,2 mm) with 2x10 screws kit for multimedia (10x13 mm & 10x22 mm deep) and 6 mounting screws delivered-by 2 plates can be mounted on top of each other within a 3-row empty area (450 mm heigth) with 10 mm spacing for cable through-out in between...
  • Page 62 Accessories FD00M3: 140 mm Ø 3,2 perforated plate (434 x 140 x 1,2 mm) with 2x5 screws kit for multimedia (5x13 mm & 5x22 mm deep) and 4 mounting screws delivered-by plates can be mounted on top of each other (1 each 1 row empty area) (150 mm heigth) with 10 mm spacing for cable through-out in between Plate compatible with device holder VZ02MM and fixing strips...
  • Page 63 Accessories 6.3.5 FD00G… = Gallery Adapter for VegaD surface versions (FD…) FD00E1 (Adapter for Systo range) has been replaced by FD00G1 (Adapter for Gallery range), as Systo range has been phased out. FD00G1: Adapter for Gallery range Gallery compatibility FD00G1 is compatible with following wiring accessories (non-exhaustive list): 16 A socket outlet 16 A socket Cable entry...
  • Page 64 Accessories Switches Switch with Other switches (with push-button function) WXF003 WXD000B WXF615B WXF010 WXD000B 2 x WXF003 2 x WXD010B 2 x WXF010 2 x WXD010B WXF008 WXD004B WXD013B WXF005 WXD005B WXF024 WXF023 WXD001B 2 x WXF023 2 x WXD011B not compatible with WS179 and 91…...
  • Page 65 Accessories All Gallery products 47 mm wide are not all compatible with Gallery adapter. Compatibility check on demand. Example: push buttons WXF610 and 611 are not compatible with FD00G1 because the wiring interferes with the plastic walls of the adapter. Technical changes reserved...
  • Page 66 918282501, 918282505, 918282507, 918282509, 918282510, 918282524, 918282578 and 919882502, 919882505, 919882506 WS179 IP41 cover for Berker socket to snap on VegaD socket Hager ref WS179 in RAL 9010 mounted on FD00G1 adapter (available in 10 colours) Berker refe- Hager re- Colour...
  • Page 67 Accessories WXF100/WXD100B+WS179 WXF615B+WS179 WXF100/WXD100B+9 1828 25 07 WXF100/WXD100B + 9 1828 25 78 All Gallery products 47mm wide are not all compatible with IP41 cover (see note in tables on page 63 and following). Example of non-compatibility: cable entry set WXF155+WXD155B is too big for WS179 and other 91…...
  • Page 68 Accessories Mounting instruction 1. Perforate side opening side with hammer [43] 2. Stick gasket on adapter [44] 3. Snap adapter into enclosure with top inscription on top [45] 4. Snap socket outlet with wires into adapter [46] Socket mounting: Step Action Put gasket on adapter Release protection foil...
  • Page 69 Accessories Step Action Take care of top side for socket adaptions and snap adapter into enclosure Fix wires to socket Pass wires into side opening Clip socket into adapter  See mounting instruction Technical changes reserved...
  • Page 70 Accessories Socket dismounting: Step Action Unscrew socket front cover 4 x unsnap with small flat screwdriver socket snaps (from outside or inside) and push socket out of enclosure 2 x unsnap adapter snaps with heavy finger pressure top/bottom or left/right hand side See mounting instruction To dismount a socket outlet, it is necessary to unscrew front plate and unsnap...
  • Page 71: Fd00F

    Accessories 6.3.6 FD00F… = Fixation kit FD00F1: Fixation kit (for surface versions only) to associate 2 surface enclosures vertically to associate 2 surface enclosures horizontally Vertical association (first enclosure already wall-mounted) Needed are following parts: Technical changes reserved...
  • Page 72 Accessories Step Action Perforate holes left/right hand side with screwdriver and hammer [22] Technical changes reserved...
  • Page 73 Accessories Step Action Insert fixing plates from the top and screw them from the inside with M6 screws [23] Cut cable entry plate opening as wished and stick gasket in between [24] [25] [26] Technical changes reserved...
  • Page 74 Accessories Step Action Insert top enclosure through fixing plates above first enclosure [27] Screw them from the inside with M6 screws [27] Put insulation caps above all M6 screw heads [27] Horizontal association (first enclosure already wall-mounted) Needed are following parts: Technical changes reserved...
  • Page 75 Accessories Step Action Perforate holes top/bottom side with screwdriver and hammer [29] Insert fixing plates from the side and screw them from the inside with M6 screws [30] Technical changes reserved...
  • Page 76 Accessories Step Action Perforate side openings with a hammer and stick gasket around them [31] [32] Insert side plates top/bottom from the inside [33] Snap second enclosure from the side over fixing plates [34] Screw them from the inside with M6 screws [34] Put insulation caps above all M6 screw heads [34] Fix second enclosure at the wall with both hands free (USP) Technical changes reserved...
  • Page 77 Accessories Horizontal association or vertical association with both enclosures on table  Same process as related above plus following step: Reinforce stability of assembly by 4x screwing top/bottom plastic parts of the enclosure with metallic back panel with 4 small screws delivered-by Technical changes reserved...
  • Page 78 Accessories FD00F2: Fixation kit (for surface versions only) to mount a surface enclosure with 4 external fixing plates Step Action Perforate holes left/hand right side and top/bottom with screwdriver and hammer [37] Technical changes reserved...
  • Page 79 Accessories Step Action Insert external fixing plates from the top and screw them from the inside with M6 screws [38] Reinforce stability of assembly by 4x screwing top/bottom plastic parts of the enclosure with metallic back panel with 4 small screws delivered-by [39] Distances between fixing holes: Width = 480 mm / Height = Enclosure height + 50 mm Technical changes reserved...
  • Page 80 Accessories FD00F3: Bar for cables fixation (for surface and flush versions) to fix incoming / outgoing cables with cable straps  Part delivered-by in each AN and DN surface version. Bar can also be fixed on the wall above cable entry Quick dismounting sideways Up to 9,5 mm width for big...
  • Page 81: Fd00H

    Accessories 6.3.7 FD00H… = DIN rail Holders for equipment units FD00H1: 2x Base element for DIN rail fixation (for surface, flush high-depth and flush low-depth versions) to use as spare part or to complete first two-rows in AN or MN versions or to equip GN versions part to snap-in on vertical upright and 1x to screw-in each 150 mm with 6 standard mounting screws delivered-by (2 for DIN rail fixation)
  • Page 82: Fd00Q

    Accessories 6.3.8 FD00Q… = Quick-Connect & terminal holder FD00Q1: 1x Quick-Connect holder (for surface, flush high-depth and flush low-depth versions) to use as spare part or to complete 22, 32, 42 or 52 versions (delivery form with only 1) Part to snap-in on back panel top/bottom plastic part Part can be optionally 2x screwed to back panel top/bottom plastic part with 4 screw bag delivered-by Fixation screws are the same than for P1, P2 and P3 cable entry plate fixing...
  • Page 83: Fd00P

    Accessories 6.3.9 FD00P… = Plate for cable entry FD00P1: 1x Plate for cable entry (Slider) with rectangular openings (for surface, flush high-depth and flush low-depth versions) Slider included top/bottom in each surface and flush version Reference to use as spare part For better stability, the plate can be 2x screwed to back panel top/bottom plastic part with 4 screw bag (Ø...
  • Page 84 Accessories FD00P2: 1x Plate for cable entry (Slider) with 2 water-proof flanges IP41 (for surface, flush high-depth and flush low-depth versions) Slider with 2 water-proof flanges IP41 to mount-in Reference to use for water-proof direct cable throughout The water-proof flanges can be ordered as single parts under VZ741 For better stability, the plate can be 2x screwed to back panel top/bottom plastic part with 4 screw bag (Ø...
  • Page 85 Accessories FD00P4: 2x Plate for cable entry (Side plate) (for surface versions only) USP: M40 cable gland head can be screwed directly into side plate winding (without its screwing ring) M25 cable gland can also be mounted-in (with its screwing ring) Technical changes reserved...
  • Page 86 Accessories FD00P5: 2x Side plate for aeration (for surface versions only) Aeration grid reduces IP41 to IP30. For mounting see page 85. Power loss effect +27 % to 64 % with kit mounted asymmetrically (for example top left- and bottom right-hand side) on distribution enclosure FD (see also chapter 'power loss' starting on page 123).
  • Page 87 2 x 5,0 – 9,0 mm 1 x 7,5 – 12,0 mm USP: Openings can be reclosed with finger touch and contain a cable strain relief functionality For mounting see page 85. FD00P6 FD00P6 mounting into New VegaD surface board Technical changes reserved...
  • Page 88 All enclosure back panels can receive 2 flanges for cable back entry (top and bottom) Reference is also part of slider FD00P2 This flange is also mounted in Vector boxes VE… VZ741 Example: Cable entry flange VZ741 mounted on the back of a New VegaD flush enclosure Technical changes reserved...
  • Page 89: Fd00S

    Accessories 6.3.10 FD00S… = Serrure (closing system) FD00S0: Standard closing system as spare part Mounting / Dismounting schema FD00S1 / FD00S4: key closing system 1242E / 405 Mounting schema Technical changes reserved...
  • Page 90 Accessories FD00S2 / FD00S3 / FD00S5: special closing system triangle 7 mm / square 7 mm / two-way 3 mm All references are delivered with tool Mounting schema Technical changes reserved...
  • Page 91: Fd00T

    Accessories 6.3.11 FD00T… = Trunking For having a nice parallel cable management from MCBs with 1 or 2 outgoings (18 mm or 9 mm distance between wires) to horizontal cable tray, a new cutting tool has been made for BA7A profiles. The resulting cable trays have 9 mm distance between slots and are available under FD00T1 and FD00T2 product codes.
  • Page 92 FD00H1 (see red arrows). Standard BA7A profile with 12,5 mm interslot distance are also compatible with New VegaD fixing, but have to be cut from 2 m profile to 438 mm length by the installer.
  • Page 93: Ba7A/Ha7

    BA7A/HA7… = vertical trunkings sideways BA7A and HA7 trunking references shown in table above are compatible with brackets FD00B1 (see page 56) and can be mounted vertically in New VegaD surface enclosures. Thus, it is possible to combine horizontal and vertical trunkings to get a clean installation picture.
  • Page 94 6.3.13 FZ… = Univers cable storage and hiding box In order to hide incoming cables over a New VegaD surface enclosure like FD52..., customer can "puzzle" a wooden-based bulky storing box or can order cable storing ducts FZ…, developed for the Univers range:...
  • Page 95 Accessories FZ142: width 550 mm, cross section 155 x 115 mm (RAL 9010) FZ142 550 mm wide (RAL 9010) Cross sec- tion [mm] 115 x 155 155 x 115 Technical changes reserved...
  • Page 96 Accessories FZ442: width 550 mm, cross section 195 x 155 mm (RAL 9010) FZ442 550 mm wide (RAL 9010) Cross sec- tion [mm] 155 x 195 195 x 155 Technical changes reserved...
  • Page 97 Accessories FZ352: width 550 mm, cross section 195 x 155 mm (RAL 7035) FZ352 550 mm wide (RAL 7035) Cross sec- tion [mm] 155 x 195 195 x 155 Technical changes reserved...
  • Page 98 Accessories Mounting instructions: Step Action Choose long side ..or short side Screw into wall Clip in front cover Clip in side covers Technical changes reserved...
  • Page 99 Accessories Step Action Ready If needed, cut out opening for external vertical cable tray integration Technical changes reserved...
  • Page 100 Accessories Mounting examples: FZ142 FZ352 mounted mounted 155 mm 155 mm vertically vertically FZ442 mounted 195 mm vertically FZ352+ FZ442 mounted 195 mm vertically Technical changes reserved...
  • Page 101 Accessories 6.3.14 UZ…V. = Univers N cable brackets UZ01V1: 20x adapter for cable bracket Univers N The adapter can be mounted on standard Univers DIN rail in each hole with flower shape The adapter can receive small bracket UZ25V2 (surface, flush high-depth and flush low-depth versions) or big bracket UZ25V1 (surface and flush high-depth versions only) UZ25V1: 20x big bracket for cables Univers N...
  • Page 102: Door Frames As Spare Parts

    Accessories 6.3.15 Door frames as spare parts Door frames for FD…N as spare part Enclosure FD Series Reference Top/bottom Metallic side Extruded Plastic screw height (193 mm deep) ending letters plastic part part RAL 9010 plastic side kit (4 screws (2x needed) (2x needed) part for cover...
  • Page 103 Accessories Door frames for FU…N as spare part Enclosure FU Series with Reference Top/bottom Metallic side Side part for Plastic screw height high frame ending letters plastic part part RAL 9010 door latch kit (4 screws (72 mm (2x needed) (2x needed) admission 1FD02900...
  • Page 104: Vertical Uprights And Fixation Accessories

    Accessories 6.3.16 Vertical uprights and fixation accessories Vertical uprights as spare part To get vertical uprights as spare parts, kit UN0.FN + 4 screws have to be ordered. Enclosure height FD or FU size Reference ending Vertical upright kit Screw 4,8x25 letters (2 uprights (4x needed)
  • Page 105 Lock nuts are required on each corner of the internal equipment system for screwing the vertical uprights to the enclosure body. They are premounted in every New VegaD enclosure. Kit ZZ41SF (composed of 4 counterparts 5G000200) can be ordered separately, if for any reason one is missing.
  • Page 106: Packaging And Dimensions Of Enclosures

    7 Packaging and dimensions of enclosures Chapter index Pictures of packaging Packaging use at the workshop or at the construction site Labels Dimensions and weights of enclosures Technical changes reserved...
  • Page 107: Pictures Of Packaging

    Enclosures: 2-pieces Hager brand card- board packaging with 2 white Hager labels 175x90 mm Equipment units and covers: 1 piece Hager brand card- board packaging with 2 white Hager labels 85x60 mm Single parts: plastic bag packaging with 1 white Hager label...
  • Page 108: Packaging Use At The Workshop Or At The Construction Site

    Packaging and dimensions of enclosures Packaging use at the workshop or at the construction site As both surface & flush protective cardboards are made of 2 pieces, New VegaD enclosure packagings are very easy to open. At the workshop or at the...
  • Page 109: Labels

    Packaging and dimensions of enclosures Labels 7.3.1 Labels on cardboard packaging Traceability code: Enclosures 30481218 = Year 23, Day 048, Hour 12, Minute 18 Traceability code: Equipment units 30530846 = Year 23, Day 053, Hour 08, Minute 46 Traceability code: Doors 4918 = Week 49, Year 18 (2018)
  • Page 110: Dimensions And Weights Of Enclosures

    Surface enclosures without door (FD…N) N° per Weight Weight Height Width Depth Surface en- Height Width Depth palette (unpacked) (packed) (packed) (packed) (packed) closures New VegaD pcs. FD22AN FD22DN FD22GN FD22LN FD22MN FD22RN FD32AN FD32DN 11,3 FD32GN FD32LN 10,9 FD32MN FD32RN 11,3 FD32ZN...
  • Page 111 Surface enclosures with door (FD…N) N° per Weight Weight Height Width Depth Surface en- Height Width Depth palette (unpacked) (packed) (packed) (packed) (packed) closures New VegaD pcs. FD22ACN 10,8 FD22BN 10,7 11,8 FD22CN 11,1 12,2 FD32ACN 12,4 13,8 FD32BN 15,4 FD32CN 14,4 15,8...
  • Page 112 Flush enclosures without door (FU…N) N° per Weight Weight Height Width Depth Flush en- Height Width Depth palette (unpacked) (packed) (packed) (packed) (packed) closures New VegaD pcs. FU22AN FU22DN FU22GN FU22LN FU22MN FU22RN FU32AN 10,3 11,4 FU32DN 11,5 12,6 FU32GN 10,4 FU32LN 11,3...
  • Page 113 Flush enclosures with door (FU…N) N° per Weight Weight Height Width Depth Flush en- Height Width Depth palette (unpacked) (packed) (packed) (packed) (packed) closures New VegaD pcs. FU22ACN 12,1 FU22BN 10,7 11,8 FU22CN 11,1 12,2 FU32ACN 14,3 15,7 FU32BN 14,2 15,6 FU32CN 14,4...
  • Page 114: Wall Fixation

    8 Wall fixation Chapter index Wall-mounting for surface enclosures Flush-mounting for flush enclosures Plaster protection in flush enclosures Technical changes reserved...
  • Page 115: Wall-Mounting For Surface Enclosures

    Wall fixation Wall-mounting for surface enclosures There are 4 fixation holes (already perforated) at the edges and 2 in the middle (to cut/punch out) to use as pre-fixation. 4 fixation holes at the edge have been enlarged to ease introduction of screw head and its grommet All FD enclosures are delivered with 5 plastic caps for covering fixation holes.
  • Page 116: Flush-Mounting For Flush Enclosures

    Wall fixation Flush-mounting for flush enclosures Flush holes dimensions are given by dims H2 and 581 mm in mounting instruction. To ensure IP30 protection without door, a depth adjustment of the frame of 15 mm max. is recommended. Frame can be depth-adjusted until 23 mm above back panel by flush high-depth and more than 35 mm by flush low-depth.
  • Page 117 Wall fixation Kit VZ405N can be mounted horizontally or vertically until 30 mm wall thickness: For hollow-wall installation it is recommended to support the lower edge of the enclosure by an accordingly designed opening, see following pictures. This ensures a good fixation over the years. It is recommended to screw-in kit VZ405N with max.
  • Page 118 Wall fixation Another new feature in New VegaD flush enclosures is the possibility to cut out the plastic top/bottom part for inserting back panel in a hollow-wall with cable arrivals both sides top/bottom. It is only possible with an added opening in back panel.
  • Page 119: Plaster Protection In Flush Enclosures

    Wall fixation Plaster protection in flush enclosures Each flush enclosure is delivered with a plaster protection cardboard to fix on back panel. Cardboard protection is the same for flush low-depth and flush high-depth, but has to be bent and may have to be turned 180° depending on flush depth to protect.
  • Page 120 Wall fixation Flush high depth: bending to exterior side red = bending line 2 x pre-perforated holes for finger taking Flush low depth: bending to interior side red = bending line Example of flush low-depth enclosure protection against plastering Technical changes reserved...
  • Page 121: Technical Data & Certifications

    9 Technical data & certifications Chapter index Technical data Power loss Certifications Technical changes reserved...
  • Page 122: Technical Data

    Technical data & certifications Technical data Product fulfils the reqirements of: DIN EN 61439-1:2012-06, EN 61439-1, IEC 61439-1:2011, VDE 0660-600-1:2012-06 DIN EN 61439-3:2013-02, EN 61439-3, IEC 61439-3:2012, VDE 0660-600-3:2013-02 Rated operational voltage and frequency: 400 / 230 V AC, 50 Hz Rated current: up to 160 A Protection class:...
  • Page 123: Power Loss

    Technical data & certifications Power loss 9.2.1 Power loss for standard surface enclosures Enclosure Permissible power loss P for standard surface enclosure perm Surface mounted with temperature rise Δt Height Width Depth % Enclosure Type 10 K 15 K 20 K 25 K 30 K height...
  • Page 124: Power Loss For Flush Low-Depth Enclosures

    Technical data & certifications 9.2.3 Power loss for flush low-depth enclosures Enclosure Permissible power loss P for flush low-depth enclosures perm Flush mounted with temperature rise Δt Height Width Depth % Enclosure Type 10 K 15 K 20 K 25 K 30 K height 10,9...
  • Page 125: Certifications

    Technical data & certifications Certifications 9.3.1 VDE certification for standard DIN/EN 61439-1/-3 Technical changes reserved...
  • Page 126: Vde Cb Certification For Standard Iec 61439-1/-3

    Technical data & certifications 9.3.2 VDE CB certification for standard IEC 61439-1/-3 Technical changes reserved...
  • Page 127: Lcie Certification For Nf Standard En 61439-1/-3

    Technical data & certifications 9.3.3 LCIE certification for NF standard EN 61439-1/-3 Technical changes reserved...
  • Page 128: Vde Certification For Standard Din/En/Iec 62208 For Empty Enclosures

    Technical data & certifications 9.3.4 VDE certification for standard DIN/EN/IEC 62208 for empty enclosures Technical changes reserved...
  • Page 129: List Of References

    List of References 10 List of References Reference Pagee Reference Pagee Reference Pagee Reference Pagee 1FD02701 FD00S0 FD52AN FU42MN 1FD05290 FD00S1 FD52BMN FU42RN 1FD05390 FD00S2 FD52BN FU52ACN 1FD05790 FD00S3 FD52CN FU52AN 1FD05890 FD00S4 FD52DN FU52BN 1FD05990 FD00S5 FD52GN FU52CN 1FD10390 FD00T1 FD52LN FU52DN...
  • Page 130: Index

    Door frames as spare parts • 102 ventilation openings FD00P5 • 123 Door hinges • 39 Product range by New VegaD flush • 24 Door mounting into enclosure frames • 38 Product range by New VegaD surface • 9 Doors for flush and surface enclosures • 35 Proper use •...
  • Page 131 Hager Electro GmbH und Co. KG Zum Gunterstal D-66440 Blieskastel GERMANY Tel.: +49 6842 945 0 Fax: +49 6842 945 4625 E-Mail: info@hager.de hager.de 6LE007135C Version 1.2 07/2023...

Table of Contents