hager New VegaD Technical Manual

hager New VegaD Technical Manual

For surface-mounting flush-mounting & accessories
Hide thumbs Also See for New VegaD:
Table of Contents

Advertisement

Technical Manual
New VegaD
for surface-mounting
fl ush-mounting
& Accessories

Advertisement

Table of Contents
loading

Summary of Contents for hager New VegaD

  • Page 1 Technical Manual New VegaD for surface-mounting fl ush-mounting & Accessories...
  • Page 2: Table Of Contents

    Table of contents Table of contents About this manual For your safety Product range by New VegaD surface External dimensions Market-specific product ranges 3.2.1 DN Version 3.2.2 AN Version 3.2.3 BN Version 3.2.4 BMN Version 3.2.5 CN Version 3.2.6 LN Version 3.2.7...
  • Page 3 Table of contents 6.2.4 FD00M… = Mounting plates 6.2.5 FD00E… = Electrical adapter for socket outlet 6.2.6 FD00F… = Fixation kit 6.2.7 FD00H… = DIN rail Holders for equipment units 6.2.8 FD00Q… = Quick-Connect & terminal holder 6.2.9 FD00P… = Plate for cable entry 6.2.10 FD00S…...
  • Page 4: About This Manual

    These instructions are an integral part of the New VegaD enclosures. Subject of the manual This document is intended for users of the flush- and surface-mounted New VegaD enclosures made by Hager. The instruction manual describes both the technology and the product ranges agreed with the respective markets, including accessories and spare parts required at the time of publication.
  • Page 5: For Your Safety

    IP30/40/41, for residential and commercial buildings with a maximum supply current of 160 A. New VegaD flush enclosures are installed at a depth of 110 mm in the wall. They are available in 6 different heights and 2 different depths.
  • Page 6 For your safety The New VegaD is not suitable for use: in areas that require a higher protection type, in areas where ATEX directives must be observed, in operating sites at risk of fire, in corrosive environments. In particular, the enclosure and internal components can become damaged if used in chlorinated, sulphurous, acidic or saline environments.
  • Page 7: Product Range By New Vegad Surface

    Product range by New VegaD surface Product range by New VegaD surface External dimensions FDX2 BN / CN / DN / LN / RN / ZN / ACN full equipped FDX2 AN / MN partly equipped FDX2 BMN partly equipped, Multimedia...
  • Page 8 About the New VegaD enclosure FDX2GN empty FDX2ZN tarif bleu triphasé Technical changes reserved...
  • Page 9: Market-Specific Product Ranges

    About the New VegaD enclosure Market-specific product ranges 3.2.1 DN Version full equipped without door with Quick-Connect terminals Green/Yellow main market: France 4 screws Multi- kit 4x16 5 caps Paper Instruction PEN QC functional kit for cover Quick- sheet with...
  • Page 10: An Version

    About the New VegaD enclosure 3.2.2 AN Version partly equipped without door two first rows to complete with Quick-Connect terminals Green/Yellow main market: France 4 screws Multi- Instruction kit 4x16 5 caps Paper PEN QC functional sheet with kit for...
  • Page 11: Bn Version

    About the New VegaD enclosure 3.2.3 BN Version full equipped with plain door door mounted-in, door opening angle 135° with Quick-Connect terminals Green/Yellow main market: Belgium 4 screws 5 caps Paper Multi- Instruction PEN QC kit 4x16 for kit for...
  • Page 12: Bmn Version

    About the New VegaD enclosure 3.2.4 BMN Version full equipped with plain door door mounted-in, door opening angle 135° with Quick-Connect terminal Green/Yellow main market: Belgium 4 screws kit 4x16 5 caps Paper Multi- Instruction PEN QC kit for cover...
  • Page 13 About the New VegaD enclosure FD00P5 Parts delivered-by in each BMN enclosure FZ794 VZ00ASF Example: multimedia enclosure FD42BMN (left) associated with standard enclosure FD42CN (right) Technical changes reserved...
  • Page 14: Cn Version

    About the New VegaD enclosure 3.2.5 CN Version full equipped with transparent door door mounted-in, door opening angle 135° with Quick-Connect terminals Green/Yellow main market: Belgium 4 screws 5 caps Paper Multi- Instruction PEN QC kit 4x16 for kit for...
  • Page 15: Ln Version

    About the New VegaD enclosure 3.2.6 LN Version full equipped without door without Quick-Connect terminals main market: Italy Multi- 4 screws Instruction Paper cover PEN QC holder functional kit 4x16 for 5 caps kit for Equipment sheet w/o Cover slot...
  • Page 16: Gn Version

    About the New VegaD enclosure 3.2.7 GN Version empty without door without Quick-Connect terminals main market: Italy Instruction sheet 4 screws kit 4x16 for PEN QC holder 24 5 caps kit for covering Equipment delivered-by with Quick-Connect optional PEN holder or...
  • Page 17: Rn Version

    About the New VegaD enclosure 3.2.8 RN Version full equipped without door with Quick-Connect terminals Green/Yellow & Blue main market: Greece 4 screws 5 caps kit Multi- Instruction Paper cover PEN QC kit 4x16 for for covering Quick- functional sheet with...
  • Page 18: Mn Version

    About the New VegaD enclosure 3.2.9 MN Version partly-equipped without door two first rows to complete with Quick-Connect terminals Green/Yellow & Blue main market: Greece 4 screws Instruction Paper cover PEN QC Multi- kit 4x16 for 5 caps kit Quick-...
  • Page 19: Zn Version

    About the New VegaD enclosure 3.2.10 ZN Version equipped with French platine kit Tarif bleu triphasé without door main market: France Instruction sheet 4 screws kit 4x16 for 5 caps kit for Paper cover Kit Michaud Platine Equipment standard with Quick-Connect...
  • Page 20: Acn Version

    About the New VegaD enclosure 3.2.11 ACN Version full equipped with transparent door door mounted-in with Quick-Connect terminals Green/Yellow main market: Africa 4 screws Instruction PEN QC Multi- kit 4x16 for 5 caps kit DIN A4 12 Quick- sheet with...
  • Page 21: Product Range By New Vegad Flush

    About the New VegaD enclosure Product range by New VegaD flush External dimensions FUX2LN full equipped FUX2 AN / MN partly equipped FUX2GN empty Technical changes reserved...
  • Page 22: Market-Specific Product Ranges

    About the New VegaD enclosure Market-specific product ranges 4.2.1 DN Version full equipped without door with Quick-Connect terminals Green/Yellow main market: France 4 screws Instruction Paper cover PEN QC kit 4x16 for Quick- Side cable sheet with Plaster marking Equipment...
  • Page 23: An Version

    Product range by New VegaD flush About the New VegaD enclosure 4.2.2 AN Version partly equipped without door two first rows to complete with Quick-Connect terminals Green/Yellow main market: France 4 screws Paper Instruction PEN QC kit 4x16 for cover...
  • Page 24: Bn Version

    About the New VegaD enclosure 4.2.3 BN Version full equipped with plain door door mounted-in with Quick-Connect terminals Green/Yellow main market: Belgium 4 screws Paper Instruction PEN QC kit 4x16 for cover Quick- Side cable sheet with Plaster Equipment holder 24...
  • Page 25: Cn Version

    About the New VegaD enclosure 4.2.4 CN Version full equipped with transparent door door mounted-in with Quick-Connect terminals Green/Yellow main market: Belgium 4 screws Paper Instruction PEN QC kit 4x16 for cover Quick- Side cable sheet with Plaster Equipment holder 24...
  • Page 26: Ln Version

    About the New VegaD enclosure 4.2.5 LN Version full equipped without door without Quick-Connect terminals main market: Italy Instruction 4 screws Paper cover PEN QC holder sheet w kit 4x16 for Plaster Equipment Side cable Cover slot marking strips 24 modules...
  • Page 27: Gn Version

    Product range by New VegaD flush About the New VegaD enclosure 4.2.6 GN Version empty without door without Quick-Connect terminals main market: Italy Instruction sheet 4 screws kit 4x16 for PEN QC holder 24 Plaster cardboard Equipment standard with Quick-Connect...
  • Page 28: Rn Version

    About the New VegaD enclosure 4.2.7 RN Version full-equipped without door with Quick-Connect terminals Green/Yellow & Blue main market: Greece 4 screws Paper Instruction PEN QC kit 4x16 for cover Quick- Side cable sheet with Plaster Equipment holder 24 Cover slot...
  • Page 29: Mn Version

    Product range by New VegaD flush About the New VegaD enclosure 4.2.8 MN Version partly-equipped without door two first rows to complete with Quick-Connect terminals Green/Yellow & Blue main market: Greece 4 screws Paper Instruction PEN QC kit 4x16 for...
  • Page 30: Doors For Flush And Surface Enclosures

    Doors for flush and surface enclosures Doors for fl ush and surface enclosures External dimensions PN Version - plain door full steel Door door 1.2mm material thick FD22PN FD32PN FD42PN FD52PN FD62PN FD72PN TN Version - transparent door Tempered Door material glass FD22TN...
  • Page 31 Doors for flush and surface enclosures Standard closing system can be sealed with max Ø1,5mm wire Standard closing system is available as spare part with reference FD00S0 Technical changes reserved...
  • Page 32: Door Mounting Into Enclosure Frames

    Doors for flush and surface enclosures Door mounting into enclosure frames In New VegaD flush enclosures, customer doesn´t have to punch out metal openings for door closing latch anymore, as they are already punched. This point was heavily criticized by customers speaking about old VegaD flush, as the punching-out of steel part could have caused damages on frame or injuries.
  • Page 33: Door Hinges

    Doors for flush and surface enclosures Door hinges Each door is composed of 1 fi x hinge and 1 removable one. Both hinge positions can be adjusted up to ~2mm by hand by turning small wheel (arrow), so that door fi ts perfectly into frame.
  • Page 34: Accessories

    Accessories Accessories Equipment units, accessories and spare parts for New VegaD system have been named according these rules: fi rst 2 letters: always FD fi rst number: 0 for equipment units, accessories and spare parts (New VegaD system only) second number:...
  • Page 35: Equipment Units

    Accessories Equipment units Equipment units are compatible with surface and fl ush high-depth versions. Equipment units are not compatible with fl ush low-depth versions. 6.1.1 FD01.. = Equipment units, height 150 mm FD01A1 : Kit for 1 distribution DIN rail (430 x 150 x 147 mm) with 1x label holder+paperstrip 24 modules, 4 mounting screws and 2 cable brackets for surface delivered-by with 150mm slotted cover 24 modules.
  • Page 36 Accessories FD01K1 : Kit for 160A MCCB horizontal 3- and 4 poles (430 x 150 x 147 mm) with 1x label holder+paperstrip 24 mod, 1 blanking strip 1,5 module (27mm) and 4 mounting screws delivered-by MCCB H3 or H3+ 3- or 4-poles 160A to screw-in horizontally label holder &...
  • Page 37 Accessories MCCB fixing on metal plate with M4 screws delivered-by Technical changes reserved...
  • Page 38: Fd02

    Accessories 6.1.2 FD02.. = Equipment units, height 300 mm FD02A1 : Kit with 2 distribution DIN rails (430 x 300 x 147 mm) with 2x label holder+paperstrip 24 mod, 4 mounting screws and 4 cable brackets surface delivered-by. with 300mm 2x slotted cover 24 mod. FD02A2 : Kit with 2 depth-adjustable DIN rails (430 x 300 x 147 mm) with 8 mounting screws and 4 DIN rail insulating parts delivered-by with 300mm plain cover...
  • Page 39 Accessories FD02A3 : Kit with 1 depth-adjustable DIN rail and 1 standard DIN rail (430 x 300 x 147 mm) with 1x label holder+paperstrip 24 mod, 2 cable brackets surface, 8 mounting screws and 2 DIN rail insulating parts delivered-by with 300mm 1x slotted cover 24 mod.
  • Page 40 Accessories FD02F1 : Kit with french DB plate (for Disjoncteur de Branchement) (430 x 300 x 147 mm) with 2x label holder+paperstrip 7 mod premounted, 4 premounted screws delivered-by with removable 7 mod. DIN rail insulation parts with 250 x 250 x 40 mm French Gamma platine premounted FD02F2 : Kit with french DB + linky meter plate (430 x 300 x 147 mm) with 2x label holder+paperstrip 7 mod and 4 premounted screws delivered-by with removable 7 mod.
  • Page 41 Accessories FD02K1 : Kit for 160A MCCB vertical 3- and 4 poles (430 x 300 x 147 mm) with 1x label holder+paperstrip 24 mod, 1 plastic elevation part for modular devices, 1 blanking strip 12 mod, 2 cable brackets surface and 4 mounting screws delivered-by MCCB H3 3- or 4-poles 160A to snap-in on DIN rail Kit also compatible with MCCB H3+ P160 3- or 4-poles  ...
  • Page 42 Accessories Technical changes reserved...
  • Page 43 1x label holder+paperstrip 24 mod, 1 blanking strip 24 mod, 1 positioning aid metallic bar and 4 mounting screws delivered-by Kit can be mounted in New VegaD surface FDxxxN and fl ush high-depth FUxxAN -GN -MN enclosures for mounting Socomec modular switches HIC4..A until 160A.
  • Page 44: Fd03

    Accessories 6.1.3 FD03.. = Equipment units, height 450 mm FD03A1 : Kit with 3 distribution DIN rails (430 x 450 x 147 mm) with 3x label holder+paperstrip 24 mod, 12 mounting screws and 6 cable brackets surface delivered-by with 3x 150mm slotted cover 24 mod. FD03Z1 : Kit with 3 distribution DIN rails (430 x 450 x 147 mm) with French platine kit Tarif bleu triphasé...
  • Page 45: Single And Spare Parts

    Accessories Single and spare parts 6.2.1 FD00A… = Standard accessories FD00A1 : 10x label holder+paperstrip 24 mod all 24 mod slotted covers in enclosures and equipment kits are already delivered with 1x label holder+paperstrip 24 mod to snap-in Reference to use as spare part or to double labels on a row (top and bottom, for example for Tebis with 2 outputs) paper length 428 mm 1-sided printed, other side blank...
  • Page 46 Accessories FD00A3 : partition plate (surface only) 24 mod FD00A4 : partition plate (fl ush high-depth only) 24 mod FD00A5 : partition plate (fl ush low-depth only) 24 mod Partition IP2X to mount in 3 diff erent positions: Pos. 1: direct on uprights (no cut-out, direct use) Pos.
  • Page 47 Accessories See mounting instruction below: Technical changes reserved...
  • Page 48 Accessories Technical changes reserved...
  • Page 49: Fd00B

    Accessories 6.2.2 FD00B… = Side brackets for vertical cables FD00B1: 10x side Brackets for vertical cables for surface versions all equipped surface enclosures and kits with 24 mod. DIN rails are already delivered with 2 brackets per DIN rail Reference to use as spare part or to complete fi rst two-rows in AN or MN versions or to equip GN versions USP: Part can be used in 3 diff...
  • Page 50 Accessories Pos. 1: Part can be snapped-in into 3 diff erent depths (20 mm raster) and loosen though fi nger pressure under orange DIN rail holder. Pos. 2: Part can be snapped-in into 3 diff erent depths (20 mm raster) and loosen though fi nger pressure under orange DIN rail holder.
  • Page 51 Accessories FD00B2: 10x side Brackets for vertical cables for fl ush versions all fl ush enclosures are already delivered with 2 brackets per DIN rail Reference to use as spare part or to complete fi rst two-rows in AN or MN versions or to equip GN versions Part can be snapped-in into 1 single position and loosen: through pressure from top with screwdriver on plastic lever (fl ush low depth)
  • Page 52 Accessories Technical changes reserved...
  • Page 53: Fd00C

    Accessories 6.2.3 FD00C… = Covers Covers can be mounted on all surface and flush enclosures FD00C1 : 300mm 2x slotted cover 24 mod. with 2x label holder+paperstrip 24 mod delivered-by FD00C2 : 300mm plain cover 24 mod. Inside flat area: 430 x 268 mm 2 slots top/bottom enable fixing of marking strips FD00A1 Technical changes reserved...
  • Page 54 Accessories FD00C3 : 300mm 1x slotted cover 24 mod. with 1x label holder+paperstrip 24 mod delivered-by 2 slots top/bottom enable fixing of marking strips FD00A1 FD00C4 : 150mm 1x slotted cover 24 mod. with 1x label holder+paperstrip 24 mod delivered-by 2 slots top/bottom enable fixing of marking strips FD00A1 FD00C5 : 150mm plain cover 24 mod.
  • Page 55: Fd00M

    Accessories 6.2.4 FD00M… = Mounting plates Mounting plates can be screwed on all surface and flush enclosures, directly on vertical uprights FD00M1 : 215mm Ø3,2 perforated plate (434 x 215 x 1,2 mm) with 2x10 screws kit for multimedia (10x13mm & 10x22mm deep) and 6 mounting screws delivered-by 2 plates can be mounted on top of each other within a 3-row empty area (450mm heigth) with 10mm spacing for cable through-out in between Plate compatible with device holder VZ02MM...
  • Page 56 Accessories FD00M3 : 140mm Ø3,2 perforated plate (434 x 140 x 1,2 mm) with 2x5 screws kit for multimedia (5x13mm & 5x22mm deep) and 4 mounting screws delivered-by plates can be mounted on top of each other (1 each 1-row empty area) (150mm heigth) with 10mm spacing for cable through-out in between Plate compatible with device holder VZ02MM (not included)
  • Page 57: Fd00E

    Accessories 6.2.5 FD00E… = Electrical adapter for socket outlet FD00E1 : Fixation kit (for surface versions) Compatible with (non exhaustive list): 16A socket Push-buttons RJ45 USB, HDMI Switches Berker cover outlets Integro flow WS100, WS032 WWS219 WS264 WS010 WS179 WS101, WS160 WS033 WS265...
  • Page 58 Accessories WS032 WS010 Not compatible Not compatible with Berker cover with Berker cover WS035 WS601 (LEDs) WS264 WS265 WS155 2x WS219 2x WS687 Half modules Half modules Not compatible with Berker cover Technical changes reserved...
  • Page 59 Accessories WS100 WS101 WS106 WS160 Systo products 45mm wide with middle snap only are currently not compatible with Systo adapter (excepted 2x half modules). WS023T WS211 WS601 Not compatible Not compatible Compatible Technical changes reserved...
  • Page 60 Systo adapter (example WS136 whom back part is too wide for entering in adapter). WS136 Not compatible IP41 Cover for Systo and Berker socket to snap Hager ref WS179 created for France in RAL9010 on VegaD socket adapter (available in 10 colours) Berker Hager Colour...
  • Page 61 Accessories WS100 + WS179 WS035 + WS179 WS100 + 9 1828 25 07 WS100 + 9 1828 25 78 Mounting / dismounting: FD00E1 1. Perforate side opening side with hammer [43] Technical changes reserved...
  • Page 62 Accessories 2. Stick gasket on adapter [44] 3. Snap adapter into enclosure with top inscription on top [45] 4. Snap socket outlet with wires into adapter [46] Socket mounting: Step Action Put gasket on adapter Release protection foil Technical changes reserved...
  • Page 63 Accessories Step Action Take care of side for socket adaptions and snap-in adapter into enclosure Fix wires to socket Pass wires into side opening Clip-in Socket into adapter → See mounting instruction Technical changes reserved...
  • Page 64 Accessories Socket dismounting: Step Action Unscrew socket front cover 4x Unsnap with small flat screwdriver socket snaps (from outside or inside) and push socket out of enclosure 2x Unsnap adapter snaps with heavy finger pressure top/bottom or left/right hand side →...
  • Page 65: Fd00F

    Accessories 6.2.6 FD00F… = Fixation kit FD00F1 : Fixation kit (for surface versions only) to associate 2 surface enclosures vertically to associate 2 surface enclosures horizontally Vertical association (fi rst enclosure already wall-mounted): needed are following parts: Technical changes reserved...
  • Page 66 Accessories Step Action Perforate holes left/right hand side with screwdriver or hammer [22] Technical changes reserved...
  • Page 67 Accessories Step Action Insert fi xing plates from the top and screw them from the inside with M6 screws [23] Cut cable entry plate opening as wished and stick gasket in between [24] [25] [26] Technical changes reserved...
  • Page 68 Accessories Step Action Insert top enclosure through fixing plates above first enclosure [27] Screw them from the inside with M6 screws [27] Put insulation caps above all M6 screw heads [27] Horizontal association (first enclosure already wall-mounted): needed are following parts: Technical changes reserved...
  • Page 69 Accessories Step Action Perforate holes top/bottom side with screwdriver or hammer [29] Technical changes reserved...
  • Page 70 Accessories Step Action Insert fixing plates from the side and screw them from the inside with M6 screws [30] Perforate side openings with a hammer and stick gasket around them [31] [32] Insert side plates top/bottom from the inside [33] Technical changes reserved...
  • Page 71 Accessories Step Action Snap second enclosure from the side over fixing plates [34] Screw them from the inside with M6 screws [34] Ppt insulation caps above all M6 screw heads [34] Fix second enclosure at the wall with both hands free (USP) Horizontal association (both enclosures on table): Vertical association (both enclosures on table): ->...
  • Page 72 Accessories FD00F2 : Fixation kit (for surface versions only) to mount a surface enclosure with 4 external fi xing plates Step Action Perforate holes left/hand right side and top/bottom with screwdriver or hammer [37] Technical changes reserved...
  • Page 73 Accessories Step Action Insert external fixing plates from the top and screw them from the inside with M6 screws [38] Reinforce stability of assembly by 4x screwing top/bottom plastic parts with metallic back panel with 4 small screws delivered-by [39] Distances between key holes: Width = 480 mm / Height = Enclosure height + 50mm Technical changes reserved...
  • Page 74 Accessories FD00F3 : Bar for cables fi xation (for surface and fl ush versions) to fi x incoming / outgoing cables with cable straps -> Part delivered-by in each AN and DN surface version Technical changes reserved...
  • Page 75 Accessories Technical changes reserved...
  • Page 76: Fd00H

    Accessories 6.2.7 FD00H… = DIN rail Holders for equipment units FD00H1 : 2x Base element for DIN rail fixation (for surface, flush high-depth and flush low-depth versions) to use as spare part or to complete first two-rows in AN or MN versions or to equip GN versions Part to snap-in on vertical upright and 1x to screw-in each 150mm with 4 standard mounting screws delivered-by Kit to complete with FD00H2 and UZ02B9...
  • Page 77: Fd00Q

    Accessories 6.2.8 FD00Q… = Quick-Connect & terminal holder FD00Q1 : 1x Quick-Connect holder (for surface, fl ush high-depth and fl ush low-depth versions) to use as spare part or to complete 22, 32, 42 or 52 versions (delivery form with only 1) Part to snap-in on back panel top/bottom plastic part Part can be optionally 2x screwed to back panel top/bottom plastic part with 4 screw bag delivered-by Fixation screws are the same than for P1, P2 and P3 cable entry plate fi xing (Ø4x16mm).
  • Page 78 Accessories Other terminal blocks and jumpers are available for neutral and phase like KNxxN, KNxxP... FD00Q2 : 1x brass terminal holder (for surface, flush high-depth and flush low-depth versions) to complete all versions for K… brass terminals mounting Part to screw-in on back panel top/bottom plastic part with fixation screws Ø4x16mm delivered-by Same width / capacity as Univers holder UT92A, compatible with KN00A universal QC holder FD00Q2 KN00A...
  • Page 79: Fd00P

    Accessories 6.2.9 FD00P… = Plate for cable entry FD00P1 : 1x Plate for cable entry (Slider) with rectangular openings (for surface, fl ush high-depth and fl ush low-depth versions) Slider included top/bottom in each fl ush version Reference to use as spare part Part can be optionally 2x screwed to back panel top/bottom plastic part with 4 screw bag (Ø4x16mm) delivered-by Total rectangular area for cable entry: 420x80 mm...
  • Page 80 Accessories FD00P2 : 1x Plate for cable entry (Slider) with 2 water-proof flanges IP41 (for surface, flush high-depth and flush low-depth versions) Slider with 2 water-proof flanges IP41 to mount-in Reference to use for waterproof direct cable throughout Flanges can be ordered as single parts under VZ741 Part can be optionally 2x screwed to back panel top/bottom plastic part with 4 screw bag (Ø4x16mm) delivered-by FD00P3 : 1x Plate for cable entry (Slider) with tube openings (for surface, flush high-depth and flush...
  • Page 81 Accessories FD00P4 : 2x Plate for cable entry (Side plate) (for surface versions only) USP: M40 cable gland head can be screwed directly into side plate winding (without its screwing ring) M25 cable gland can also be mounted-in (with its screwing ring) FD00P4 FD00P5 FD00P6...
  • Page 82 Accessories FD00P5 : 2x Side plate for aeration (for surface versions only) Aeration grid reduces IP41 to IP30. For Mounting, see page 78. Power loss effect +27 to 64% with kit mounted asymmetrically (for example top left- and bottom right- hand side) on distribution enclosure FD (see also §...
  • Page 83 - 2 x 5,0 – 9,0mm - 1 x 7,5 – 12,0mm Openings can be reclosed with finger touch and contain a cable strain relief functionality for Mounting, see page 78 FD00P6 FD00P6 mounting into New VegaD surface board Technical changes reserved...
  • Page 84 All enclosure back panels can receive 2 flanges for cable back entry (top and bottom) Reference is also part of slider FD00P2 Flange has been already existing and still mounted in Vector boxes VE… VZ741 Example: Flange VZ741 mounted on the back of a New VegaD flush enclosure Technical changes reserved...
  • Page 85: Fd00S

    Accessories 6.2.10 FD00S… = Serrure (closing system) FD00S0 : Standard closing system as spare part Mounting / Dismounting schema FD00S1 / FD00S4 : key closing system 1242E / 405 Mounting schema Technical changes reserved...
  • Page 86 Accessories FD00S2 / FD00S3 / FD00S5 : special closing system triangle 7mm / square 7mm / two-way 3mm All references are delivered with tool Mounting schema Technical changes reserved...
  • Page 87: Fd00T

    Accessories 6.2.11 FD00T… = Trunking For having a nice parallel cable management from MCBs with 1 or 2 outgoings (18 mm or 9mm distance between wires) to horizontal cable tray, a new cutting tool has been made for BA7A profi les. FD00T1: 4x horizontal cable tray kit 80x30 with 9mm interslot distance in PVC dark grey colour RAL7030 438mm width for horizontal quick fi xing between 2 rows without tool...
  • Page 88 Both horizontal trunkings can be quickly fixed between 2 rows without tool, simply by clipping them on black base element FD00H1 (see red arrows). Standard BA7A profile with 12,5 interslot distance are also compatible with New VegaD fixing, but have to be cut from 2m profile to 438mm length by customer.
  • Page 89: Ba7A/Ha7

    BA7A and HA7 trunking references shown in table above are compatible with brackets FD00B1 (see 6.2.2) and can be mounted vertically in New VegaD surface enclosures. Thus, it is possible to combine horizontal and vertical trunkings to get a clean installation picture.
  • Page 90 FZ… = Univers cable storage and hiding box In order to hide incoming cables over a New VegaD surface enclosure like FD52..., customer can “puzzle“ a wooden-based bulky storing box or can order cable storing ducts FZ…, developed about 10 years...
  • Page 91 Accessories FZ142 550mm wide (RAL9010) FZ142 550mm wide (RAL9010) Cross section 115x155 155x115 Technical changes reserved...
  • Page 92 Accessories FZ442 550mm wide (RAL9010) FZ442 550mm wide (RAL9010) Cross section 155x195 195x155 Technical changes reserved...
  • Page 93 Accessories FZ352 550mm wide (RAL7035) FZ352 550mm wide (RAL7035) Cross section 155x195 195x155 Technical changes reserved...
  • Page 94 Accessories Mounting instructions: Step Action Choose long side ..or short side Screw-in into wall Clip-in front cover Clip-in side covers Technical changes reserved...
  • Page 95 Accessories Step Action Ready If needed, cut out opening for external vertical cable tray integration Technical changes reserved...
  • Page 96 Accessories Mounting examples: FZ142 FZ352 mounted mounted 155mm 155mm vertically vertically FZ442 mounted 195mm vertically FZ352+ FZ442 mounted 195mm vertically Technical changes reserved...
  • Page 97 Accessories 6.2.14 UZ…V. = Univers N cable brackets UZ01V1: 20x Adapter for cable bracket Univers N Part can be mounted-in on standard Univers DIN rail in each hole with fl ower shape Part can receive small bracket UZ25V2 (surface, fl ush high-depth and fl ush low-depth versions) or big bracket UZ25V1 (surface and fl ush high-depth versions only) UZ25V1: 20x big bracket for cables Univers N Part to snap-in on adapter UZ01V1...
  • Page 98 Accessories UZ25V2: 20x small bracket for cables Univers N Part to snap-in on adapter UZ01V1 Single cover UT50C from cable tray Univers can be snapped on its top to hide cables below Part can be also mounted 180° without adapter under standard Univers DIN rail in each hole with fl ower shape (surface and fl ush high-depth versions only) UZ01V1 UZ25V2...
  • Page 99: Door Frames As Spare Parts

    Accessories 6.2.15 Door frames as spare parts Door frames for FD…N as spare part Extruded Plastic screw Top/bottom Metallic side plastic side Enclosure FD Serie Reference kit (4 screws plastic part part RAL9010 part for cover height (193 mm deep) ending letters 1FD02900 (2x needed)
  • Page 100 Accessories Door frames for FU…N as spare part Plastic screw FU Serie with Top/bottom Metallic side Side part for door Enclosure Reference kit (4 screws high frame plastic part part RAL9010 latch admission height ending letters 1FD02900 (72mm overhead) (2x needed) (2x needed) (2x needed) included)
  • Page 101: Vertical Uprights And Fixation Accessories

    Accessories 6.2.16 Vertical uprights and fixation accessories Vertical uprights as spare part To get vertical uprights as spare parts, kit UN0.FN + 4 screws have to be ordered. Vertical upright Enclosure Reference screw 4,8x25 FD or FU size kit (2 uprights height ending letters (4x needed)
  • Page 102 Steel springs are needed in each corner to fix the vertical uprights to the enclosure body. They are premounted in every New VegaD enclosure. These springs can be ordered separately, if for any reason one is missing, with following reference:...
  • Page 103: Packaging And Dimensions Of Enclosures

    1 piece hager brand cardboard packaging with 2x white hager labels 85x60mm Single parts: plastic bag packaging with 1x white hager label 85x60mm or pre-printed Single doors: 1-piece hager brand cardboard packaging with 2x white hager labels 100x73mm Technical changes reserved...
  • Page 104: Packaging Use At Shopfloor

    Packaging use at shopfloor As both surface & flush protective cardboards are made of 2-pieces, New vegaD enclosure packagings are very easy to open. At shop floor, it is also recommended to use the first half for protecting frame or frame with door and the other half to for protecting back panel, chassis or door.
  • Page 105: Labels

    Packaging and dimensions of enclosures Labels 7.3.1 Labels on cardboard packaging Traceability code: Enclosures 059 = Week 05, Year 9 (2019) Equipment units 059 = Week 05, Year 9 (2019) Doors 4918 = Week 49, Year 18 (2018) Technical changes reserved...
  • Page 106: Enclosure Type Labels

    Packaging and dimensions of enclosures 7.3.2 Enclosure type labels Traceability code: Enclosures 190291551 = Year 19 Day 029 Hour 15 Minute 51 Technical changes reserved...
  • Page 107: Dimensions Of Enclosures

    Packaging and dimensions of enclosures Dimensions of enclosures 7.4.1 Surface enclosures without door (FD…N) Surface nb per weight weight Height width depth Enclosures Height width depth Palette (unpacked) (packed) (packed) (packed) (packed) NewVegaD FD22AN FD22DN FD22GN FD22LN FD22MN FD22RN FD32AN FD32DN 11,3 FD32GN...
  • Page 108 Packaging and dimensions of enclosures 7.4.2 Surface enclosures with door (FD…N) Surface nb per weight weight Height width depth Enclosures Height width depth Palette (unpacked) (packed) (packed) (packed) (packed) NewVegaD FD22ACN 10,8 FD22BN 10,7 11,8 FD22CN 11,1 12,2 FD32ACN 12,4 13,8 FD32BN 15,4...
  • Page 109 Packaging and dimensions of enclosures 7.4.3 Flush enclosures without door (FU…N) Flush enclosures nb per weight weight Height width depth NewVegaD Height width depth Palette (unpacked) (packed) (packed) (packed) (packed) FU22AN FU22DN FU22GN FU22LN FU22MN FU22RN FU32AN 10,3 11,4 FU32DN 11,5 12,6 FU32GN...
  • Page 110 Packaging and dimensions of enclosures 7.4.4 Flush enclosures with door (FU…N) Flush nb per weight weight Height width depth enclosures Height width depth Palette (unpacked) (packed) (packed) (packed) (packed) NewVegaD FU22BN 10,7 11,8 FU22CN 11,1 12,2 FU32BN 14,2 15,6 FU32CN 14,4 15,8 FU42BN...
  • Page 111: Wall Fixation

    Wall fixation Wall fi xation Wall-mounting for surface enclosures 4 fi xation holes (already perforated) at the edge + 2 in the middle (to cut/punch out) to use as pre-fi xation 4 fi xation holes at the edge have been enlarged to ease introduction of screw head and its grommet All FD enclosures are delivered with 5 plastic caps for covering fi xation holes...
  • Page 112: Flush-Mounting For Flush Enclosures

    Wall fixation Flush-mounting for flush enclosures Flush holes dimensions are given by dims H2 and 581mm in mounting instruction. To ensure IP30 protection without door is 15mm frame regulation recommended. Frame can be regulate until 23mm above back panel (flush high depth) and more than 35mm by flush low depth. For hollow-wall fixation, the kit VZ405N can be used.
  • Page 113 Wall fixation Kit VZ405N can be mounted horizontally or vertically until 30mm wall thickness: It is recommended to set back panel on wall edges to support weight before using hollow-wall kit, to ensure good fi xation over years. It is recommended to screw-in kit with max. 2 Nm torque. Technical changes reserved...
  • Page 114 Wall fixation Another new feature in New VegaD flush enclosures is the possibility to cut out the plastic top/bottom part for inserting back panel in a hollow-wall with cable arrivals both sides top/bottom. It is only possible with added opening in back panel. For this, a line has been designed on plastic part (black line on the picture), so that the customer can follow it with its cutter and needs only to cut-out plastic.
  • Page 115: Plaster Protection In Flush Enclosures

    Wall fixation Plaster protection in flush enclosures Each flush enclosure is delivered with a plaster protection cardboard to fix on back panel. Cardboard protection is the same for flush low depth and flush high-depth, but has to be bend and may have to be turned 180°...
  • Page 116 Wall fixation Example of flush low-depth enclosure protection against plastering Technical changes reserved...
  • Page 117: Technical Datas & Certifications

    Technical datas & certifications Technical datas & certifications Technical datas & certifications Technical datas product fulfils the reqirement of: DIN EN 61439-1:2012-06, EN 61439-1, IEC 61439-1: 2011, VDE 06606001: 201206 DIN EN 61439-3:2013-02, EN 61439-3, IEC 61439-3: 2012, VDE 06606003: 201302 Rated operational voltage and frequency: AC 400/230V, 50 Hz Rated current: until 160A...
  • Page 118: Power Loss

    Technical datas & certifications Power loss 9.2.1 Power loss for standard surface enclosures: Enclosure Permissible power loss P for standard surface enclosures perm Surface mounted with temperature rise Δt Height Width Depth Type % Enclosure height 15,0 24,8 35,4 46,8 58,7 FD22..
  • Page 119: Power Loss For Standard Flush-Low Depth Enclosures

    Technical datas & certifications 9.2.3 Power loss for standard flush-low depth enclosures: Enclosure Permissible power loss P for standard flush-low depth enclosures perm Flush mounted with temperature rise Δt Height Width Depth Type % Enclosure height 10,9 18,0 25,7 33,9 42,5 FU22..
  • Page 120: Certifications

    Technical datas & certifications Certifications 9.3.1 VDE certification for Standard DIN/EN 61439-1/-3 Technical changes reserved...
  • Page 121: Vde Cb Certification For Standard Iec 61439-1/-3

    Technical datas & certifications 9.3.2 VDE CB certification for Standard IEC 61439-1/-3 Technical changes reserved...
  • Page 122: Lcie Certification For Nf Standard En 61439-1/-3

    Technical datas & certifications 9.3.3 LCIE certification for NF Standard EN 61439-1/-3 Technical changes reserved...
  • Page 123: Vde Certification For Standard Din/En/Iec 62208 For Empty Enclosures

    Technical datas & certifications 9.3.4 VDE certification for Standard DIN/EN/IEC 62208 for empty enclosures Technical changes reserved...
  • Page 124: List Of References

    List of References List of References Reference Page Reference Page Reference Page Reference Page 1FD02701 FD00S5 FD52TN FU72CN 1FD05290 FD00T1 FD62ACN FU72DN 1FD05390 FD00T2 FD62AN FU72GN 1FD05790 FD01A1 FD62BN FU72LN 1FD05890 FD01A2 FD62CN FU72MN 1FD05990 FD01K1 FD62DN FU72RN 1FD10390 FD02A1 FD62GN FZ142 1FU05190...
  • Page 125: Index

    Mounting plates • 55 Packaging and dimensions of enclosures • 103 Plaster protection in flush enclosures • 115 Power loss • 118 Product range by New VegaD flush • 21 Product range by New VegaD surface • 7 Technical changes reserved...
  • Page 126 Index QuickConnect & terminal holder • 77 Screws for frame fixing • 99 Single and spare parts • 45 Storage box for cables • 90 Surface enclosures without door (FD…N) • 107 Technical datas • 117 Trunking • 87 Univers N cable brackets • 97 Vertical uprights &...
  • Page 127 Hager Electro GmbH und Co. KG Zum Gunterstal 66440 BLIESKASTEL GERMANY Tel.: +49 6842 945 0 Fax: +49 6842 945 4625 E-Mail: info@hager.de www.hager.de Hager Support Hager Vertriebsgesellschaft mbH & Co. KG Zum Gunterstal 66440 BLIESKASTEL GERMANY Tel.: +49 6842 945-4460 Fax: +49 6842 945-4445 E-Mail: svb@hager.de...

Table of Contents