Maintenance; Cleaning Instructions; Cleaning The Air Filter; Cleaning The Lens - ViewSonic Office Theater PJ860 User Manual

31" to 300" (viewable) super bright svga lcd projector
Hide thumbs Also See for Office Theater PJ860:
Table of Contents

Advertisement

Maintenance

Cleaning Instructions

To ensure that the projector functions properly, follow the recommended cleaning instructions below.

Cleaning the Air Filter

IMPORTANT: Clean the air filter about every 100 hours.
1 Turn OFF the Main Power switch of the projector and disconnect
the power cord from the wall outlet.
2 Remove the Front Filter Cover (see diagram to the right).
3 Remove the air filter from the Front Filter Cover (as shown in the
illustration to the right) and use a vacuum cleaner to clean the
filter.
4 Re-install the air filter, then the Front Filter Cover.
E
N
NOTE:
If sufficient dust, etc. collects in the air filter, a protection circuit in the projector
G
will automatically turn off the power. To prevent this from occurring, make sure you clean
L
the air filter every 100 hours.
I
S

Cleaning the Lens

H
• To clean the lens, use a camera lens cleaning tissue or a
camel hair brush.
• Be careful not to scratch the lens with a sharp or hard object.

Cleaning the Cabinet

• Use a soft, dry, lint-free cloth to wipe dust, etc. from the cabinet.
• If this is insufficient, use a soft, lint-free cloth moistened with a
mild detergent diluted with water. Then wipe the surface with a
soft, dry, lint-free cloth.

Replacing the Lamp Unit

To order a new lamp unit
1 Make sure the Main Power switch is OFF, then
disconnect the power cord from the wall outlet. If the
projector has recently been turned on, wait at least
45 minutes for the lamp to cool down.
2 Carefully place the projector onto a flat surface
covered with soft material (like a towel). Then loosen
the Lamp Cover screw and remove the Lamp Cover
(as shown to the right).
3 Loosen the two (2) lamp-unit screws, grasp the
Lamp Unit Handle, and gently pull the lamp unit out
of the projector.
4 Carefully insert the new lamp unit into the projector
and tighten the lamp-unit screws.
5 Re-install the Lamp Cover and tighten the Lamp
Cover screw securely. Power-on the projector.
6 Reset the lamp time (within 10 minutes)
• Press RESET (on projector) or TIMER (on Remote
Control Unit) and hold for three (3) seconds
• Press RESET (on projector) or MENU ON (on
Remote Control Unit)
• Select "0" on the screen using MENU [<] (on
projector) or DISKPAD (on Remote Conrol Unit)
16
Maintenance
16
01-May-01, 22:03
contact ViewSonic
(Part No. RLU-190-03A)
CAUTION: Never use any ammonia
or alcohol based cleaner on the lens.
CAUTION: Never use any
ammonia or alcohol-based
cleaner to clean the cabinet.
®
Customer Support.
Replace the lamp unit if:
• the picture is dark
• "CHANGE THE LAMP" is
displayed
Lamp
• the lamp indicator on the
Cover
projector remains lit red.
(See page 14.)
Screws
CAUTION:
HANDLE THE LAMP UNIT
CAREFULLY. Dropping
the unit could cause the
lamp to explode.
Lamp Unit
Handle
Reflector
Front Filter
Cover
Front
Glass
Lamp Unit
ViewSonic PJ860

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vprj21558-2Pj860-2

Table of Contents