Electronic Test Equipment - Infra-Red Thermometer - Kamco CF40 Operating And Servicing Manual

Clearflow power flushing pumps
Hide thumbs Also See for CF40:
Table of Contents

Advertisement

ELECTRONIC TESTING EQUIPMENT – INFRA-RED THERMOMETER
Simply aim the infra-red thermometer at the target area
and depress the trigger to measure the surface
temperature.
The "SCAN" icon will appear in the LCD display. When the
trigger is released the reading is automatically held for
15seconds and "HOLD" is displayed on the LCD, after
which the thermometer will shut down.
Specification
Range
-50 to +330°C
Resolution
0.1°C
Accuracy
+/- 2%
Battery life
80 hrs continuous
Auto off
after 10 seconds
Measurement Zone
The measurement zone is proportional to the distance
the thermometer is away from the target. The
thermometer is equipped with a 12:1 lens. If the target is
60cm (24") away, the measurement zone will be 5cm (2")
across.
Laser Pointer
The centre of the measurement zone is 16mm below the
laser dot when held horizontally.
For safety reasons the laser pointer will only activate
when the trigger button is depressed.
Prolonged, continuous exposure such as staring at the
beam can be harmful and should be avoided. Do not look
at the beam with any optical instruments.
Issue: May 2023
Section F – Power Flushing Accessories
Unit of measurement
The instrument default is to measure in °C.
Batteries
The low battery icon indicates that the batteries need
replacing as soon as possible. The instrument will
continue to function but to maintain accuracy new
batteries are required.
Storage and cleaning
The sensor lens is the most delicate part of the
thermometer and the lens should be kept clean at all
times.
Care should be taken when cleaning the lens using only a
soft cloth or cotton swab with water or medical alcohol,
allowing the lens to fully dry before use.
Do not submerge any part of the thermometer.
The unit should be stored at room temperature between
+10 to +40°C.
Page F.12

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cf90Cf210

Table of Contents